/content/sps/us/en/search-results.html

Portables

AreaRAE Plus

Transportable area monitor for multiple threat detection

Overview
The AreaRAE Plus provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to configure device. Plus, you’ll have vital details about threats happening in real-time—arming you with the information you need to act quickly.Features and Benefits:
  • Monitors up to seven threats, including VOCs, combustibles, Toxics and Oxygen
  • Optional meteorological sensor for tracking toxic plumes
  • 7R+ photoionization detector (PID) for monitoring VOCs at parts per million
  • Secondary radio module (Mesh) act as an communication Hub for other wireless devices
  • Ruggedized, portable, and weather-resistant design for harsh environments
  • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations
Application:
  • Confined Space Entry
  • Environmental Cleanups/ Remediation
  • Fence Line Monitoring
  • Leak Detection
  • Plant Shutdown & Turn-Around
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • RAE

Sampling

  • Sampling Pump Range
    • 100ft (30m)

Dimensions

  • Weight
    • 14.33 US Pound
    • 6.5 kilogram

Category

  • Sub-Category
    • Transportable

Dimension & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Range

  • Humidity Range
    • 0%-95% percent
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)

Alarm

  • Alarm Type
    • Audible, Visual, Vibrating

Battery & Charging

  • Battery Run Time
    • 20 hours

Certifications

  • Standards & Certifications
    • US and Canada: Class 1, Division 2, Groups A, B, C, D

Datalogging

  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

Features & Benefits

  • Features & Benefits
    • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat

Options

  • User Options
    • 3 operation and programming keys

Warranty

  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Wireless

  • Wireless Technology
    • BLE, MESH, WiFi, LORA

Additional Specifications

  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
  • Ingress Protection
    • IP65

Others

  • Maximum Temperature
    • 140 degree Fahrenheit
    • 60 degree Celsius
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit

Brand

  • Brand
    • RAE

Sampling

  • Sampling Pump Range
    • 100ft (30m)

Dimensions

  • Weight
    • 14.33 US Pound
    • 6.5 kilogram

Category

  • Sub-Category
    • Transportable

Dimension & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Range

  • Humidity Range
    • 0%-95% percent
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)

Alarm

  • Alarm Type
    • Audible, Visual, Vibrating

Battery & Charging

  • Battery Run Time
    • 20 hours

Certifications

  • Standards & Certifications
    • US and Canada: Class 1, Division 2, Groups A, B, C, D

Datalogging

  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

Features & Benefits

  • Features & Benefits
    • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat

Options

  • User Options
    • 3 operation and programming keys

Warranty

  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Wireless

  • Wireless Technology
    • BLE, MESH, WiFi, LORA

Additional Specifications

  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
  • Ingress Protection
    • IP65

Others

  • Maximum Temperature
    • 140 degree Fahrenheit
    • 60 degree Celsius
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Brand : RAE
  • Sampling Pump Range : 100ft (30m)
  • Weight : 14.33 US Pound|6.5 kilogram
  • Maximum Temperature : 140 degree Fahrenheit|60 degree Celsius
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Sub-Category : Transportable
  • Instrument Size : 12.36” x 12.04” x 6.53”
  • Humidity Range : 0%-95% percent
  • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Alarm Type : Audible, Visual, Vibrating
  • Battery Run Time : 20 hours
  • Standards & Certifications : US and Canada: Class 1, Division 2, Groups A, B, C, D
  • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Features & Benefits : Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
  • User Options : 3 operation and programming keys
  • Warranty : Four years for O2 Liquid Oxygen sensors
  • Wireless Technology : BLE, MESH, WiFi, LORA
  • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
  • Ingress Protection : IP65
Data Sheet
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
application/pdf 569.87 KB
7/15/2021
569.87 KB
Manuals and Guides
Name
Description
File Size
Date
Size
AreaRAE Plus & AreaRAE Pro - User Guide - English
application/pdf 18.86 MB
4/12/2023
18.86 MB
AreaRAE Pro and AreaRAE Plus QuickStart Guide
application/pdf 1.8 MB
1/11/2022
1.8 MB
Firmware
Name
Description
File Size
Date
Size
Area RAE 1.12 Firmware and Release Notes
application/zip 2.01 MB
8/18/2023
2.01 MB
AREARAE Plus / Pro v 1.08
application/zip 1.57 MB
7/15/2021
1.57 MB
Brochure
Name
Description
File Size
Date
Size
AreaRAE Plus Brochure
application/pdf 3.23 MB
7/15/2021
3.23 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
application/pdf 146.2 KB
8/10/2022
146.2 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
7/15/2021
884.91 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
Technical Note 144 Handling LEL Sensor Poisons
application/pdf 802.28 KB
8/3/2022
802.28 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
7/15/2021
1.08 MB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
application/pdf 1.02 MB
7/15/2021
1.02 MB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
2/8/2022
1.09 MB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
11/1/2022
1.45 MB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
AreaRAE PlusPro Technical Note 106A
application/pdf 428.08 KB
7/15/2021
428.08 KB
White Paper
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
7/15/2021
949.42 KB
Certificate
Name
Description
File Size
Date
Size
AreaRAE Plus and Pro - EU Declaration of Conformity
application/pdf 154.78 KB
1/11/2022
154.78 KB
AreaRAE Plus and Pro - Certificate of compliance
application/pdf 45.13 KB
9/27/2021
45.13 KB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
application/pdf 194.1 KB
1/11/2022
194.1 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Application Note 215: Gas Detection In The Marine Industries
application/pdf 889.61 KB
7/15/2021
889.61 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
7/15/2021
1.07 MB
Application Note 228 - Facility and Venue Protection
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
7/15/2021
831.7 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 750.69 KB
7/15/2021
750.69 KB
Name
Description
File Size
Date
Size
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
7/15/2021
911.54 KB
Area RAE 1.12 Firmware and Release Notes
2.01 MB
8/18/2023
2.01 MB
AreaRAE Plus & AreaRAE Pro - User Guide - English
18.86 MB
4/12/2023
18.86 MB
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
146.2 KB
8/10/2022
146.2 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
7/15/2021
884.91 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
7/15/2021
609.21 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
8/3/2022
839.29 KB
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
8/3/2022
802.28 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
7/15/2021
964.88 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
7/15/2021
787.55 KB
Application Note 215: Gas Detection In The Marine Industries
889.61 KB
7/15/2021
889.61 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
1.1 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
7/15/2021
826.34 KB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
125.12 KB
1/23/2024
125.12 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
7/15/2021
1.08 MB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/14/2022
839.32 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
7/15/2021
944.51 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
7/15/2021
1.07 MB
Application Note 228 - Facility and Venue Protection
1.1 MB
7/15/2021
1.1 MB
AreaRAE Plus and Pro - EU Declaration of Conformity
154.78 KB
1/11/2022
154.78 KB
AreaRAE Plus and Pro - Certificate of compliance
45.13 KB
9/27/2021
45.13 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
1.02 MB
7/15/2021
1.02 MB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
2/8/2022
1.09 MB
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
8/3/2022
994.45 KB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
7/15/2021
1.26 MB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
7/15/2021
795.02 KB
AreaRAE Pro and AreaRAE Plus QuickStart Guide
1.8 MB
1/11/2022
1.8 MB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
11/1/2022
785.04 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
788.83 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
7/15/2021
831.7 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
655.59 KB
AreaRAE Plus Datasheet
569.87 KB
7/15/2021
569.87 KB
AREARAE Plus / Pro v 1.08
1.57 MB
7/15/2021
1.57 MB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
7/15/2021
949.42 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
7/15/2021
950.72 KB
AreaRAE Plus Brochure
3.23 MB
7/15/2021
3.23 MB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
7/15/2021
814.89 KB
RM2400A EU Component of Conformity to Certificates
110.56 KB
1/3/2022
110.56 KB
A Guideline for Pid Instrument Response
1.45 MB
11/1/2022
1.45 MB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
7/15/2021
930.69 KB
AreaRAE PlusPro Technical Note 106A
428.08 KB
7/15/2021
428.08 KB
AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
194.1 KB
1/11/2022
194.1 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
7/15/2021
750.69 KB
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
569.87 KB
7/15/2021
AreaRAE Plus & AreaRAE Pro - User Guide - English
18.86 MB
4/12/2023
AreaRAE Pro and AreaRAE Plus QuickStart Guide
1.8 MB
1/11/2022
Area RAE 1.12 Firmware and Release Notes
2.01 MB
8/18/2023
AREARAE Plus / Pro v 1.08
1.57 MB
7/15/2021
AreaRAE Plus Brochure
3.23 MB
7/15/2021
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
7/15/2021
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
146.2 KB
8/10/2022
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
7/15/2021
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
7/15/2021
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
8/3/2022
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
8/3/2022
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
7/15/2021
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
125.12 KB
1/23/2024
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
7/15/2021
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/14/2022
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
7/15/2021
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
1.02 MB
7/15/2021
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
2/8/2022
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
8/3/2022
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
7/15/2021
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
11/1/2022
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
7/15/2021
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
7/15/2021
A Guideline for Pid Instrument Response
1.45 MB
11/1/2022
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
7/15/2021
AreaRAE PlusPro Technical Note 106A
428.08 KB
7/15/2021
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
7/15/2021
AreaRAE Plus and Pro - EU Declaration of Conformity
154.78 KB
1/11/2022
AreaRAE Plus and Pro - Certificate of compliance
45.13 KB
9/27/2021
RM2400A EU Component of Conformity to Certificates
110.56 KB
1/3/2022
AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
194.1 KB
1/11/2022
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
7/15/2021
Application Note 215: Gas Detection In The Marine Industries
889.61 KB
7/15/2021
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
7/15/2021
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
7/15/2021
Application Note 228 - Facility and Venue Protection
1.1 MB
7/15/2021
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
7/15/2021
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
7/15/2021
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
7/15/2021