/content/sps/us/en/search-results.html

Portables

AutoRAE 2

Automatic bump test and calibration system

Overview

Simplify bump testing and calibration of your RAE Systems gas monitors with the AutoRAE 2. Versatile and modular, it can be deployed as a single, stand-alone unit to calibrate one instrument at a time, or networked to support up to 10 units at once and calibrate for up to five distinct gases. One-touch bump testing and single-button operation for calibration make it easy to use. Upgradeable firmware protects your investment and ensures that it’s always up-to-date, while the standard SD card for storage ensures your data is always at your fingertips.

Features and Benefits:

  • Easy, one-touch bump testing, calibration, charging, and records management
  • Supports a wide variety of gases, including exotics
  • Optimized for field use--does not require a computer to operate
  • Can be used on a bench top or mounted on the wall
  • Deployable as a standalone cradle or a controller-based system with up to 10 cradles
  • Networking capability
  • Data storage on a standard SD card
  • Instrument supported:ToxiRAE Pro, ToxiRAE Pro LEL, ToxiRAE Pro PID, ToxiRAE Pro CO2: QRAE 3: MicroRAE, MulitRAE Lite (pumped version only), MulitRAE, MultiRAE Pro, MultiRAE Benzene, MiniRAE Lite, MiniRAE 3000, UltraRAE 3000 and ppbRAE3000

Application:

  • CBRNE
  • Clandestine Labs
  • Confined Space Entry
  • Decontamination
  • Emergency Response
  • Environmental Cleanups/ Remediation
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Indoor Air Quality
  • Leak Detection
  • Plant Shutdown & Turn-Around
  • Residential Calls
  • Urban Search & Rescue
  • Venue Protection
  • Worker Exposure
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • RAE

Dimensions

  • Weight
    • 0.86 kilogram
    • 1.9 US Pound

Category

  • Sub-Category
    • Docks

Certifications

  • Standards & Certifications
    • CE

Features & Benefits

  • Features & Benefits
    • Easy- one-touch bump testing- calibration- charging- and records

Flow Rate

  • Flow rate
    • 500 millilitre per minute

Options

  • User Options
    • PC-based configuration via software. Can be performed using networking capability

Warranty

  • Warranty
    • 2-year limited warranty

Wireless

  • Wireless Technology
    • Direct cable (RJ-45 10/100 Base T port)

Additional Specifications

  • Power Supply
    • AC adapter (110 V to 240 V input, 12 V output, 7.5 A)

Others

  • Data Storage Capacity
    • 2 gallon (US) per day
    • 2

Brand

  • Brand
    • RAE

Dimensions

  • Weight
    • 0.86 kilogram
    • 1.9 US Pound

Category

  • Sub-Category
    • Docks

Certifications

  • Standards & Certifications
    • CE

Features & Benefits

  • Features & Benefits
    • Easy- one-touch bump testing- calibration- charging- and records

Flow Rate

  • Flow rate
    • 500 millilitre per minute

Options

  • User Options
    • PC-based configuration via software. Can be performed using networking capability

Warranty

  • Warranty
    • 2-year limited warranty

Wireless

  • Wireless Technology
    • Direct cable (RJ-45 10/100 Base T port)

Additional Specifications

  • Power Supply
    • AC adapter (110 V to 240 V input, 12 V output, 7.5 A)

Others

  • Data Storage Capacity
    • 2 gallon (US) per day
    • 2
  • Brand : RAE
  • Data Storage Capacity : 2 gallon (US) per day|2
  • Weight : 0.86 kilogram|1.9 US Pound
  • Sub-Category : Docks
  • Standards & Certifications : CE
  • Features & Benefits : Easy- one-touch bump testing- calibration- charging- and records
  • Flow rate : 500 millilitre per minute
  • User Options : PC-based configuration via software. Can be performed using networking capability
  • Warranty : 2-year limited warranty
  • Wireless Technology : Direct cable (RJ-45 10/100 Base T port)
  • Power Supply : AC adapter (110 V to 240 V input, 12 V output, 7.5 A)
Data Sheet
Name
Description
File Size
Date
Size
AutoRAE 2 Data Sheet
application/pdf 326.86 KB
7/15/2021
326.86 KB
Manuals and Guides
Name
Description
File Size
Date
Size
AutoRAE 2 User Manual
application/pdf 18.07 MB
11/23/2023
18.07 MB
AutoRAE 2 Quick Reference Guide
application/pdf 1.12 MB
11/23/2023
1.12 MB
Firmware
Name
Description
File Size
Date
Size
AutoRAE 2 Cradle for Handheld PID v1.38
application/zip 173.08 KB
10/27/2021
173.08 KB
AutoRAE 2 Cradle For Handheld PID V1.44
application/zip 174.19 KB
9/4/2023
174.19 KB
AutoRAE 2 Controller Application Firmware v1.44
application/zip 2.14 MB
9/4/2023
2.14 MB
AutoRAE 2 Cradle For ToxiRAE Pro Monitors v 1.44
application/zip 174.21 KB
9/4/2023
174.21 KB
AutoRAE 2 Cradle For MultiRAE Pumped Monitors v 1.42.2
application/zip 173.9 KB
2/1/2023
173.9 KB
AutoRAE 2 Cradle For QRAE 3 Monitors v 1.42.2
application/zip 173.87 KB
2/1/2023
173.87 KB
AutoRAE 2 Cradle For MicroRAE Monitors v 1.42.2
application/zip 173.88 KB
2/1/2023
173.88 KB
AutoRAE 2 Cradle For MultiRAE Pumped Monitors v 1.38
application/zip 173.09 KB
11/3/2021
173.09 KB
AutoRAE 2 Cradle For ToxiRAE Pro Monitors v 1.38
application/zip 173.08 KB
7/15/2021
173.08 KB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
Technical Note 203 Gas Sequences for Calibration and Calibration Check Testing of the MultiRAE Instrument Family
application/pdf 1.15 MB
7/15/2021
1.15 MB
Certificate
Name
Description
File Size
Date
Size
AutoRAE 2 EU Declaration of Conformity
application/pdf 170.12 KB
1/4/2022
170.12 KB
Others
Name
Description
File Size
Date
Size
AutoRAE 2 User's Guide
application/pdf 7.69 MB
7/15/2021
7.69 MB
Name
Description
File Size
Date
Size
AutoRAE 2 Cradle for Handheld PID v1.38
173.08 KB
10/27/2021
173.08 KB
AutoRAE 2 User Manual
18.07 MB
11/23/2023
18.07 MB
AutoRAE 2 Quick Reference Guide
1.12 MB
11/23/2023
1.12 MB
AutoRAE 2 Cradle For Handheld PID V1.44
174.19 KB
9/4/2023
174.19 KB
AutoRAE 2 Controller Application Firmware v1.44
2.14 MB
9/4/2023
2.14 MB
AutoRAE 2 Cradle For ToxiRAE Pro Monitors v 1.44
174.21 KB
9/4/2023
174.21 KB
AutoRAE 2 Cradle For MultiRAE Pumped Monitors v 1.42.2
173.9 KB
2/1/2023
173.9 KB
AutoRAE 2 Cradle For QRAE 3 Monitors v 1.42.2
173.87 KB
2/1/2023
173.87 KB
AutoRAE 2 Cradle For MicroRAE Monitors v 1.42.2
173.88 KB
2/1/2023
173.88 KB
AutoRAE 2 Data Sheet
326.86 KB
7/15/2021
326.86 KB
AutoRAE 2 Cradle For MultiRAE Pumped Monitors v 1.38
173.09 KB
11/3/2021
173.09 KB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/14/2022
839.32 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
7/15/2021
795.02 KB
AutoRAE 2 Cradle For ToxiRAE Pro Monitors v 1.38
173.08 KB
7/15/2021
173.08 KB
AutoRAE 2 User's Guide
7.69 MB
7/15/2021
7.69 MB
Technical Note 203 Gas Sequences for Calibration and Calibration Check Testing of the MultiRAE Instrument Family
1.15 MB
7/15/2021
1.15 MB
AutoRAE 2 EU Declaration of Conformity
170.12 KB
1/4/2022
170.12 KB
Name
Description
File Size
Date
Size
AutoRAE 2 Data Sheet
326.86 KB
7/15/2021
AutoRAE 2 User Manual
18.07 MB
11/23/2023
AutoRAE 2 Quick Reference Guide
1.12 MB
11/23/2023
AutoRAE 2 Cradle for Handheld PID v1.38
173.08 KB
10/27/2021
AutoRAE 2 Cradle For Handheld PID V1.44
174.19 KB
9/4/2023
AutoRAE 2 Controller Application Firmware v1.44
2.14 MB
9/4/2023
AutoRAE 2 Cradle For ToxiRAE Pro Monitors v 1.44
174.21 KB
9/4/2023
AutoRAE 2 Cradle For MultiRAE Pumped Monitors v 1.42.2
173.9 KB
2/1/2023
AutoRAE 2 Cradle For QRAE 3 Monitors v 1.42.2
173.87 KB
2/1/2023
AutoRAE 2 Cradle For MicroRAE Monitors v 1.42.2
173.88 KB
2/1/2023
AutoRAE 2 Cradle For MultiRAE Pumped Monitors v 1.38
173.09 KB
11/3/2021
AutoRAE 2 Cradle For ToxiRAE Pro Monitors v 1.38
173.08 KB
7/15/2021
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/14/2022
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
7/15/2021
Technical Note 203 Gas Sequences for Calibration and Calibration Check Testing of the MultiRAE Instrument Family
1.15 MB
7/15/2021
AutoRAE 2 EU Declaration of Conformity
170.12 KB
1/4/2022
AutoRAE 2 User's Guide
7.69 MB
7/15/2021
Product Number
Image
SKU
Description
alt
002-3008-000
Organic vapor zeroing kit ((charcoal filter trap) multiple use, with connectors
alt
410-0225-000
Ethernet cable
alt
500-0141-000
Power adapter,AC/DC,90-264V Input,12VDC/7.5A 90W Output
alt
T01-0100-000
Bump Test and Calibration (ToxiRAE 3 version)
alt
T01-1011-000
PCB,ASSY,BUTTON,AUTORAE LITE
alt
T01-1013-000
PCB,ASSY,ADAPTER,AUTORAE LITE
alt
T01-2002-000
TOXIRAE 3 RBR FOR SGL ADTR AUTORAE LITE
alt
T01-3029-000
ADAPTOR W/ CABLE,AUTORAE LITE FOR QRAE I
alt
T02-0003-000
AutoRAE 2 Cradle for ToxiRAE Pro
alt
T02-0103-000
AutoRAE 2 Cradle for MultiRAE Pumped Models
Image
SKU
Description
alt
002-3008-000
Organic vapor zeroing kit ((charcoal filter trap) multiple use, with connectors
alt
410-0225-000
Ethernet cable
alt
500-0141-000
Power adapter,AC/DC,90-264V Input,12VDC/7.5A 90W Output
alt
T01-0100-000
Bump Test and Calibration (ToxiRAE 3 version)
alt
T01-1011-000
PCB,ASSY,BUTTON,AUTORAE LITE
alt
T01-1013-000
PCB,ASSY,ADAPTER,AUTORAE LITE
alt
T01-2002-000
TOXIRAE 3 RBR FOR SGL ADTR AUTORAE LITE
alt
T01-3029-000
ADAPTOR W/ CABLE,AUTORAE LITE FOR QRAE I
alt
T02-0003-000
AutoRAE 2 Cradle for ToxiRAE Pro
alt
T02-0103-000
AutoRAE 2 Cradle for MultiRAE Pumped Models