https://sps.honeywell.com/us/en/search-results.html
Outage Notification: On Saturday, June 5,12:30-2:30 p.m. EDT (6:30 to 8:30 p.m. UDT), this website will undergo planned maintenance. Thank you for your patience.

Portables

AreaRAE Pro

The first choice of first responders

For years, you’ve relied on AreaRAE as a first line of defense. As the threats have evolved, our technology has, too. Today’s AreaRAE Pro wireless multi-gas, multi-threat detector is equipped with more sensors, more versatility, and more insight into threats happening in real-time—arming you with the information you need when seconds count.

Features and Benefits:

  • Monitors up to seven threats, including Gamma radiation , VOCs, combustibles, Toxics and Oxygen
  • Ppb performance level on VOCs measurement
  • Dedicated gamma sensor slot
  • Local weather station
  • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations
  • Wireless technology sends real-time data to command station up to two miles (3km) away
  • Secondary radio module (Mesh) act as an communication Hub for other wireless devices
  • Ruggedized, portable, and weather-resistant design for harsh environments

Application:

  • CBRNE
  • Clandestine Labs
  • Decontamination
  • Emergency Response
  • Fire Overhaul
  • Hazmat Response
  • Urban Search & Rescue
  • Venue Protection

Others

  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Sampling Pump Range
    • 100ft 30m
  • Maximum Temperature
    • 60 degree Celsius
    • 140 degree Fahrenheit
  • Weight
    • 14.33 US Pound
    • 6.5 keg
  • Battery Run Time
    • 12-20 Hours
    • 44185hours
  • Standards
    • US / Canada: Class 1- Division 2 Groups A- B- C- D
    • US / Canada: Class 1, Division 2 Groups A, B, C, D
  • Benefits
    • • Delivers real-time readings to Honeywell’s
  • Instrument Size
    • 12.36” x 12.04” x 6.53”
  • Alarm Type
    • Visual- Audible- Vibrating
    • Visual, Audible, Vibrating
  • Wireless Technology
    • BLE, MESH, WiFi
    • BLE- MESH- WiFi
  • Datalogging
    • Continuous data logging 90 days for 7 gas sensors, 1 Gamma
    • Continuous data logging 90 days for 7 gas sensors- 1 Gamma
  • Gas Type
    • VOC- LEL- CO2- NH3- CO- Cl2- ETO- H2- HCL- HCN- HF- H2S- O2- SO2- NO- NO2- PH3- Gamma
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma
  • Warranty
    • Four years for O2 Liquid Oxygen sensors
  • User Options
    • 3 operation and programming keys
  • Sensor Range
    • VOC 0-2000ppm- LEL 0-100%LEL- CO2 0-50000ppm- NH3 0-100ppm- CO 0-2000ppm- Cl2 0-50ppm- ETO 0-500ppm- H2 0-2000ppm- HCL 0-15ppm- HCN 0-50ppm- HF 0.5-10ppm- H2S 0-1000ppm- O2 0-30%- SO2 0-20ppm- NO 0-250ppm- NO2 0-20ppm- PH3 0-20ppm- Gamma 0.01 μSv/h to 0.2 mSv/h
    • VOC 0-2000ppm, LEL 0-100%LEL, CO2 0-50000ppm, NH3 0-100ppm, CO 0-2000ppm, Cl2 0-50ppm, ETO 0-500ppm, H2 0-2000ppm, HCL 0-15ppm, HCN 0-50ppm, HF 0.5-10ppm, H2S 0-1000ppm, O2 0-30%, SO2 0-20ppm, NO 0-250ppm, NO2 0-20ppm, PH3 0-20ppm, Gamma 0.01 μSv/h to 0.2 mSv/h
  • Humidity Range
    • 0%-95%
  • Ingress Protection
    • IP65

Others

  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Sampling Pump Range
    • 100ft 30m
  • Maximum Temperature
    • 60 degree Celsius
    • 140 degree Fahrenheit
  • Weight
    • 14.33 US Pound
    • 6.5 keg
  • Battery Run Time
    • 12-20 Hours
    • 44185hours
  • Standards
    • US / Canada: Class 1- Division 2 Groups A- B- C- D
    • US / Canada: Class 1, Division 2 Groups A, B, C, D
  • Benefits
    • • Delivers real-time readings to Honeywell’s
  • Instrument Size
    • 12.36” x 12.04” x 6.53”
  • Alarm Type
    • Visual- Audible- Vibrating
    • Visual, Audible, Vibrating
  • Wireless Technology
    • BLE, MESH, WiFi
    • BLE- MESH- WiFi
  • Datalogging
    • Continuous data logging 90 days for 7 gas sensors, 1 Gamma
    • Continuous data logging 90 days for 7 gas sensors- 1 Gamma
  • Gas Type
    • VOC- LEL- CO2- NH3- CO- Cl2- ETO- H2- HCL- HCN- HF- H2S- O2- SO2- NO- NO2- PH3- Gamma
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma
  • Warranty
    • Four years for O2 Liquid Oxygen sensors
  • User Options
    • 3 operation and programming keys
  • Sensor Range
    • VOC 0-2000ppm- LEL 0-100%LEL- CO2 0-50000ppm- NH3 0-100ppm- CO 0-2000ppm- Cl2 0-50ppm- ETO 0-500ppm- H2 0-2000ppm- HCL 0-15ppm- HCN 0-50ppm- HF 0.5-10ppm- H2S 0-1000ppm- O2 0-30%- SO2 0-20ppm- NO 0-250ppm- NO2 0-20ppm- PH3 0-20ppm- Gamma 0.01 μSv/h to 0.2 mSv/h
    • VOC 0-2000ppm, LEL 0-100%LEL, CO2 0-50000ppm, NH3 0-100ppm, CO 0-2000ppm, Cl2 0-50ppm, ETO 0-500ppm, H2 0-2000ppm, HCL 0-15ppm, HCN 0-50ppm, HF 0.5-10ppm, H2S 0-1000ppm, O2 0-30%, SO2 0-20ppm, NO 0-250ppm, NO2 0-20ppm, PH3 0-20ppm, Gamma 0.01 μSv/h to 0.2 mSv/h
  • Humidity Range
    • 0%-95%
  • Ingress Protection
    • IP65
  • Battery Run Time : 12-20 Hours|44185hours
  • Standards : US / Canada: Class 1- Division 2 Groups A- B- C- D|US / Canada: Class 1, Division 2 Groups A, B, C, D
  • Benefits : • Delivers real-time readings to Honeywell’s
  • Instrument Size : 12.36” x 12.04” x 6.53”
  • Alarm Type : Visual- Audible- Vibrating|Visual, Audible, Vibrating
  • Wireless Technology : BLE, MESH, WiFi|BLE- MESH- WiFi
  • Datalogging : Continuous data logging 90 days for 7 gas sensors, 1 Gamma|Continuous data logging 90 days for 7 gas sensors- 1 Gamma
  • Gas Type : VOC- LEL- CO2- NH3- CO- Cl2- ETO- H2- HCL- HCN- HF- H2S- O2- SO2- NO- NO2- PH3- Gamma|VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma
  • Warranty : Four years for O2 Liquid Oxygen sensors
  • User Options : 3 operation and programming keys
  • Sensor Range : VOC 0-2000ppm- LEL 0-100%LEL- CO2 0-50000ppm- NH3 0-100ppm- CO 0-2000ppm- Cl2 0-50ppm- ETO 0-500ppm- H2 0-2000ppm- HCL 0-15ppm- HCN 0-50ppm- HF 0.5-10ppm- H2S 0-1000ppm- O2 0-30%- SO2 0-20ppm- NO 0-250ppm- NO2 0-20ppm- PH3 0-20ppm- Gamma 0.01 μSv/h to 0.2 mSv/h|VOC 0-2000ppm, LEL 0-100%LEL, CO2 0-50000ppm, NH3 0-100ppm, CO 0-2000ppm, Cl2 0-50ppm, ETO 0-500ppm, H2 0-2000ppm, HCL 0-15ppm, HCN 0-50ppm, HF 0.5-10ppm, H2S 0-1000ppm, O2 0-30%, SO2 0-20ppm, NO 0-250ppm, NO2 0-20ppm, PH3 0-20ppm, Gamma 0.01 μSv/h to 0.2 mSv/h
  • Humidity Range : 0%-95%
  • Ingress Protection : IP65
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Sampling Pump Range : 100ft 30m
  • Weight : 14.33 US Pound|6.5 keg
  • Maximum Temperature : 60 degree Celsius|140 degree Fahrenheit
Data Sheet
Name
Description
File Size
Date
Size
AreaRAE Pro Data Sheet
application/pdf 537.7 KB
7/15/2021
537.7 KB
VOC ZeroingTube Data Sheet
application/pdf 77.52 KB
7/15/2021
77.52 KB
Manuals and Guides
Name
Description
File Size
Date
Size
AreaRAE Plus & AreaRAE Pro - User Guide
application/pdf 18.42 MB
1/11/2022
18.42 MB
AreaRAE Pro and AreaRAE Plus QuickStart Guide
application/pdf 1.8 MB
1/11/2022
1.8 MB
Firmware
Name
Description
File Size
Date
Size
AREARAE Plus / Pro v 1.08
application/zip 1.57 MB
7/15/2021
1.57 MB
Brochure
Name
Description
File Size
Date
Size
AreaRAE Pro Brochure
application/pdf 2.87 MB
7/15/2021
2.87 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
2/8/2022
1.09 MB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
11/2/2021
1.45 MB
AreaRAE PlusPro Technical Note 106A
application/pdf 428.08 KB
7/15/2021
428.08 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
7/15/2021
884.91 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
Technical Note 176 Basics Of Nuclear Radiation
application/pdf 1.31 MB
7/15/2021
1.31 MB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
application/pdf 1.1 MB
7/15/2021
1.1 MB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
application/pdf 1.02 MB
7/15/2021
1.02 MB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
7/15/2021
785.04 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
7/15/2021
839.29 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
7/15/2021
125.12 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
7/15/2021
839.32 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
7/15/2021
1.08 MB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
7/15/2021
994.45 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Technical Note 144 Handling LEL Sensor Poisons
application/pdf 802.28 KB
7/15/2021
802.28 KB
White Paper
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
7/15/2021
949.42 KB
Certificate
Name
Description
File Size
Date
Size
AreaRAE Plus and Pro - EU Declaration of Conformity
application/pdf 154.78 KB
1/11/2022
154.78 KB
AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
application/pdf 194.1 KB
1/11/2022
194.1 KB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
AreaRAE Plus and Pro - Certificate of compliance
application/pdf 45.13 KB
9/27/2021
45.13 KB
Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
application/pdf 817.01 KB
7/15/2021
817.01 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 232 Radioisotopes in Everyday Life
application/pdf 582.87 KB
3/4/2022
582.87 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
7/15/2021
1.07 MB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
7/15/2021
831.7 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 228 - Facility and Venue Protection
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
Name
Description
File Size
Date
Size
Application Note 232 Radioisotopes in Everyday Life
582.87 KB
3/4/2022
582.87 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
2/8/2022
1.09 MB
AreaRAE Plus and Pro - EU Declaration of Conformity
154.78 KB
1/11/2022
154.78 KB
AreaRAE Plus & AreaRAE Pro - User Guide
18.42 MB
1/11/2022
18.42 MB
AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
194.1 KB
1/11/2022
194.1 KB
AreaRAE Pro and AreaRAE Plus QuickStart Guide
1.8 MB
1/11/2022
1.8 MB
RM2400A EU Component of Conformity to Certificates
110.56 KB
1/3/2022
110.56 KB
A Guideline for Pid Instrument Response
1.45 MB
11/2/2021
1.45 MB
AreaRAE Plus and Pro - Certificate of compliance
45.13 KB
9/27/2021
45.13 KB
AreaRAE PlusPro Technical Note 106A
428.08 KB
7/15/2021
428.08 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
7/15/2021
1.07 MB
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
7/15/2021
884.91 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
7/15/2021
831.7 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
655.59 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
7/15/2021
609.21 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
7/15/2021
964.88 KB
Technical Note 176 Basics Of Nuclear Radiation
1.31 MB
7/15/2021
1.31 MB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
7/15/2021
949.42 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
7/15/2021
930.69 KB
Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
1.1 MB
7/15/2021
1.1 MB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
1.1 MB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
7/15/2021
787.55 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
788.83 KB
AREARAE Plus / Pro v 1.08
1.57 MB
7/15/2021
1.57 MB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
1.02 MB
7/15/2021
1.02 MB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
7/15/2021
785.04 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
7/15/2021
814.89 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
7/15/2021
950.72 KB
Application Note 228 - Facility and Venue Protection
1.1 MB
7/15/2021
1.1 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
7/15/2021
839.29 KB
AreaRAE Pro Data Sheet
537.7 KB
7/15/2021
537.7 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
7/15/2021
125.12 KB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
7/15/2021
839.32 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
7/15/2021
1.08 MB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
7/15/2021
795.02 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
7/15/2021
994.45 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
7/15/2021
911.54 KB
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
7/15/2021
802.28 KB
VOC ZeroingTube Data Sheet
77.52 KB
7/15/2021
77.52 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
7/15/2021
826.34 KB
AreaRAE Pro Brochure
2.87 MB
7/15/2021
2.87 MB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
7/15/2021
1.26 MB
Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
817.01 KB
7/15/2021
817.01 KB
Image
SKU
Description
alt
500-0066-100
Charger (120/240 V AC to 15 V DC) for AreaRAE, includes power cord with EU style 220 V AC plug
alt
500-0066-000-4A
BATTERY CHARGER,AC/DC ADPT 15V,4AMP W/ AC CORD
alt
050-0010-000
10.6 eV Interchangeable 1/4″ PID lamp
alt
029-7117-000
Antenna magnetic mount base with 12' cable (869MHz)
alt
029-3152-000
Alkaline AreaRAE battery adapter (holds 6 C batteries)
alt
029-3060-100
Charging station for single Lithium-Ion battery pack
alt
029-3060-000
Four-unit external charger for AreaRAE Lithium-ion battery pack
alt
029-3028-000
RAELink2E Host Serial Cable Assembly (Connects RAELink2E Host to a PC)
alt
029-2124-300
Tripod Kit (includes tripod and mounting bracket)
alt
W01A100001S79CDE01
AR-PRO/CSA/0PID/CO2/H2S/CO/SO2/NO/NO2/MT