https://sps.honeywell.com/us/en/search-results.html

Portables

MultiRAE Pro

Wireless, portable multi-threat monitor for radiation and chemical detection

This industry-leading wireless device monitors both chemical threats and gamma radiation and is the only multi-threat monitor with parts per billion precision. With the ability to wirelessly transmit threat and alarm data in real time to a central command station, the MultiRAE Pro offers improved visibility and awareness. It also gives you the flexibility to swap out 25 different sensors for a range of threats, including VOCs, toxic gases, combustibles, oxygen levels, as well as gamma radiation detection. The large display and replaceable sensors, pump, and battery make it easy to use and maintain, while five different alarms, including man down, provide the versatility you need to respond appropriately and quickly to incidents.Features and Benefits:
  • Parts per billion VOC measurement
  • Industry-leading wireless multi-threat device
  • Simultaneous monitoring of chemical threats and gamma radiation
  • Real-time data access from central command
  • More than 25 different chemical sensors
  • Swappable sensors
  • Man down alarm
  • Simple maintenance with replaceable sensors, pump, and battery
  • Fully automatic bump testing and calibration with AutoRAE 2
  • 5-way local and remote wireless alarm
  • Mil-STD-810G certified
  • Device Management with Honeywell Sotera™ Express
  • Readily enables to communicate with Motorola MOTOTRBO
Application:
  • CBRNE
  • Hazmat Response
  • Indoor Air Quality
  • Urban Search & Rescue
  • Venue Protection

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Benefits
    • Highly versatile and customizable
  • Humidity Range
    • 0%-95%
  • Sub-Category
    • Premium-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 122 degree Fahrenheit
  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Weight
    • 880 gram
    • 31 ounce av [Invisible]
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • MESH, Wifi, BLE
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time
    • 12-18
  • Warranty
    • Four years on Liq O2 sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Benefits
    • Highly versatile and customizable
  • Humidity Range
    • 0%-95%
  • Sub-Category
    • Premium-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 122 degree Fahrenheit
  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Weight
    • 880 gram
    • 31 ounce av [Invisible]
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • MESH, Wifi, BLE
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time
    • 12-18
  • Warranty
    • Four years on Liq O2 sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Alarm Type : Audible, Visual, Vibrating
  • Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Benefits : Highly versatile and customizable
  • Humidity Range : 0%-95%
  • Sub-Category : Premium-Gas
  • Maximum Temperature : 50 degree Celsius|122 degree Fahrenheit
  • Standards : CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Weight : 880 gram|31 ounce av [Invisible]
  • Sampling Pump Range : 100ft (30m)
  • Brand : RAE
  • Wireless Technology : MESH, Wifi, BLE
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time : 12-18
  • Warranty : Four years on Liq O2 sensors
  • Ingress Protection : IP65
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
Data Sheet
Name
Description
File Size
Date
Size
MultiRAE Pro Data Sheet
127.65 KB
12/4/2020
PDF 127.65 KB
Manuals and Guides
Name
Description
File Size
Date
Size
MultiRAE (Pumped) QuickStart Guide
302.5 KB
12/4/2020
PDF 302.5 KB
MultiRAE User Guide
8.12 MB
12/4/2020
PDF 8.12 MB
Technical Note
Name
Description
File Size
Date
Size
A Guideline for Pid Instrument Response
1.45 MB
12/4/2020
PDF 1.45 MB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/4/2020
PDF 839.32 KB
MultiRAE Series Technical Note 106B
620.4 KB
12/4/2020
PDF 620.4 KB
Technical Note 170 USB To Serial Port Adapter
1.26 MB
12/4/2020
PDF 1.26 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
12/4/2020
PDF 125.12 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
12/4/2020
PDF 950.72 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
12/4/2020
PDF 930.69 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
12/4/2020
PDF 1.09 MB
Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
813.81 KB
12/4/2020
PDF 813.81 KB
Technical Note 124 PID Lamp Characteristics
768.24 KB
12/4/2020
PDF 768.24 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
12/4/2020
PDF 911.54 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
12/4/2020
PDF 984.3 KB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
790.79 KB
12/4/2020
PDF 790.79 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
12/4/2020
PDF 814.89 KB
Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
1.1 MB
12/4/2020
PDF 1.1 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
12/4/2020
PDF 820.7 KB
Technical Note 176 Basics Of Nuclear Radiation
1.31 MB
12/4/2020
PDF 1.31 MB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Certificate
Name
Description
File Size
Date
Size
Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
817.01 KB
12/4/2020
PDF 817.01 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 214: Environmental Applications For PIDs
836.36 KB
12/4/2020
PDF 836.36 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
12/4/2020
PDF 964.88 KB
Others
Name
Description
File Size
Date
Size
MultiRAE Family IECEx Certificate of Conformity
322.45 KB
3/31/2021
PDF 322.45 KB
Name
Description
File Size
Date
Size
A Guideline for Pid Instrument Response
1.45 MB
12/4/2020
PDF 1.45 MB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/4/2020
PDF 839.32 KB
MultiRAE Series Technical Note 106B
620.4 KB
12/4/2020
PDF 620.4 KB
Technical Note 170 USB To Serial Port Adapter
1.26 MB
12/4/2020
PDF 1.26 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
12/4/2020
PDF 125.12 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
12/4/2020
PDF 950.72 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
12/4/2020
PDF 930.69 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
12/4/2020
PDF 1.09 MB
Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
813.81 KB
12/4/2020
PDF 813.81 KB
Technical Note 124 PID Lamp Characteristics
768.24 KB
12/4/2020
PDF 768.24 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
12/4/2020
PDF 911.54 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
12/4/2020
PDF 984.3 KB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
790.79 KB
12/4/2020
PDF 790.79 KB
MultiRAE (Pumped) QuickStart Guide
302.5 KB
12/4/2020
PDF 302.5 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 214: Environmental Applications For PIDs
836.36 KB
12/4/2020
PDF 836.36 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
12/4/2020
PDF 964.88 KB
MultiRAE Family IECEx Certificate of Conformity
322.45 KB
3/31/2021
PDF 322.45 KB
MultiRAE Pro Data Sheet
127.65 KB
12/4/2020
PDF 127.65 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
MultiRAE User Guide
8.12 MB
12/4/2020
PDF 8.12 MB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
12/4/2020
PDF 814.89 KB
Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
1.1 MB
12/4/2020
PDF 1.1 MB
Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
817.01 KB
12/4/2020
PDF 817.01 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
12/4/2020
PDF 820.7 KB
Technical Note 176 Basics Of Nuclear Radiation
1.31 MB
12/4/2020
PDF 1.31 MB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Image
SKU
Description
alt
MCA3-A3C1REZ-P20
MR PR/ATX/PMP/PID/LEL/CO+H2S/O2/GMA/P2P
alt
MCA3-A30002Q-020
MR PR/ATX/PMP/PID/ CO/HCHO/N-WS
alt
MCA3-000068Z-020
MR PR/ATX/PMP/ Cl2/NH3/GMA/N-WS
alt
MCA3-A3C17EZ-32F
MR PR/ATX/PMP/PID/LEL/HCN/O2/GMA/868M
alt
MCA3-01C128E-020
MR PR/ATX/PMP/H2S/LEL/CO/NH3/O2/N-WS
alt
MCA3-A3C1679-320
MR PR/ATX/PMP/PID/LEL/Cl2/HCN/PH3/868M
alt
MCA3-A3C18EZ-320
MR PR/ATX/PMP/PID/LEL/NH3/O2/GMA/868M
alt
MCA3-A1C1002-320
MR PR/ATX/PMP/PID/LEL/ CO/868M
alt
MCA3-B805789-020
MR PR/ATX/PMP/CO2/NO2/HCN/NH3/PH3/N-WS
alt
MCA3-A300DEJ-32C
MR PR/ATX/PMP/PID/ CO/O2/EtOA/868M