ppbRAE 3000 +

The most advanced wireless handheld VOC monitor with parts per billion measurement

The ppbRAE 3000+ is a best-of-breed monitor trusted by many of the world’s leaders in CBRNE, HazMat Response, Civil Defense, Oil & Gas, and other hazardous environments. Using a 3rd generation photoionization detector (PID) and built-in correction factors for more than 200 compounds, the ppbRAE 3000+ is one of the most advanced VOC monitors for parts-per-billion (ppb) detection. It measures the presence of VOCs from 1ppb-10,000ppm with a three-second response time. Optional built-in Mesh Radio enables real-time monitoring of instrument readings wirelessly. Another option is Bluetooth, which can relay readings and alarm status up to 2 miles to a RAELink 3 wireless transmitter. And a rugged housing, large display, and large keys that can be operated with three layers of gloves all make for a unit that’s easy to use and maintain.

A rugged housing, large display, and large keys that can be operated with three layers of gloves all make for a unit that’s easy to use and maintain.

ppbRAE 3000 + is solution oriented through multiple connected options. A dedicated mobile APP has been developed for survey applications. Instrument is also available with real time connectivity which can relay readings and alarm status up to 2 miles to a RAELink 3 wireless transmitter.

Features and Benefits:

  • Measures from 1ppb up to 10,000ppb
  • 3-second response time
  • Humidity compensation
  • Optional Mesh Radio for ConneXt compatibility
  • Optional BLE Module
  • Optional built-in Bluetooth transmitter that transmits real-time data up to 2 miles with RAELink3 wireless router
  • Sample pump draws from up to 100 feet
  • Correction factors for more than 350 compounds
  • Large display reports gas type, correction factor, concentration
  • Rugged housing for harsh environments
  • Sensor and lamp auto-cleaning
  • Built-in flashlight
  • Multi-language capability – up to 10 languages
  • MIL-STD-810F certified rugged housing for harsh environments
  • Patented PID lamp auto-cleaning
  • Patented Reflex PID Technology™

Application:

  • CBRNE
  • Decontamination
  • Environmental Cleanups/ Remediation
  • Hazmat Response
  • Indoor Air Quality
  • Plant Shutdown & Turn-Around
  • Urban Search & Rescue
  • Venue Protection
  • Worker Exposure

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • VOC (0-10000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Benefits
    • • 3-second response time
  • Humidity Range
    • 0%-95%
  • Sub-Category
    • Premium-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 113 degree Fahrenheit
  • Weight
    • 738 gram
    • 26 ounce av [Invisible]
  • Standards
    • • US and Canada: UL, cUL, Classified as Intrinsically Safe for use in Class I, Division
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • MESH, BLE
  • Gas Type
    • VOC
  • Datalogging
    • Standard 6 months at one-minute intervals
  • Battery Run Time
    • 12-16
  • Warranty
    • 3-year warranty for 10.6 eV lamp,
  • Ingress Protection
    • IP65
  • User Options
    • • Alarms latching with manual override or automatic reset
  • Instrument Size
    • 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • VOC (0-10000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Benefits
    • • 3-second response time
  • Humidity Range
    • 0%-95%
  • Sub-Category
    • Premium-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 113 degree Fahrenheit
  • Weight
    • 738 gram
    • 26 ounce av [Invisible]
  • Standards
    • • US and Canada: UL, cUL, Classified as Intrinsically Safe for use in Class I, Division
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • MESH, BLE
  • Gas Type
    • VOC
  • Datalogging
    • Standard 6 months at one-minute intervals
  • Battery Run Time
    • 12-16
  • Warranty
    • 3-year warranty for 10.6 eV lamp,
  • Ingress Protection
    • IP65
  • User Options
    • • Alarms latching with manual override or automatic reset
  • Instrument Size
    • 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
  • Alarm Type : Audible, Visual, Vibrating
  • Sensor Range : VOC (0-10000ppm)
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Benefits : • 3-second response time
  • Humidity Range : 0%-95%
  • Sub-Category : Premium-Gas
  • Maximum Temperature : 50 degree Celsius|113 degree Fahrenheit
  • Weight : 738 gram|26 ounce av [Invisible]
  • Standards : • US and Canada: UL, cUL, Classified as Intrinsically Safe for use in Class I, Division
  • Sampling Pump Range : 100ft (30m)
  • Brand : RAE
  • Wireless Technology : MESH, BLE
  • Gas Type : VOC
  • Datalogging : Standard 6 months at one-minute intervals
  • Battery Run Time : 12-16
  • Warranty : 3-year warranty for 10.6 eV lamp,
  • Ingress Protection : IP65
  • User Options : • Alarms latching with manual override or automatic reset
  • Instrument Size : 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
Data Sheet
Name
Description
File Size
Date
Size
ppbRAE 3000 + Data Sheet - EN
2.68 MB
7/15/2021
PDF 2.68 MB
ppbRAE 3000 + Data Sheet - NL
343.12 KB
7/15/2021
PDF 343.12 KB
ppbRAE 3000 + Data Sheet - PT
344.72 KB
7/15/2021
PDF 344.72 KB
ppbRAE 3000 + Data Sheet - RU
401.41 KB
7/15/2021
PDF 401.41 KB
ppbRAE 3000 + Data Sheet - DE
345.82 KB
7/15/2021
PDF 345.82 KB
ppbRAE 3000 + Data Sheet - IT
342.08 KB
7/15/2021
PDF 342.08 KB
ppbRAE 3000 + Data Sheet - ES
343.33 KB
7/15/2021
PDF 343.33 KB
ppbRAE 3000 + Data Sheet - FR
344.63 KB
7/15/2021
PDF 344.63 KB
Manuals and Guides
Name
Description
File Size
Date
Size
3G PID User's Guide - PL
3.91 MB
7/15/2021
PDF 3.91 MB
3G PID User Guide - IT
7.57 MB
7/15/2021
PDF 7.57 MB
3G PID User Guide - NL
7.5 MB
7/15/2021
PDF 7.5 MB
3000+ Series PID Quick Start Guide - NL
736.75 KB
7/15/2021
PDF 736.75 KB
3000+ Series PID Quick Start Guide - ES
735.47 KB
7/15/2021
PDF 735.47 KB
3G PID User Guide - DE
7.64 MB
7/15/2021
PDF 7.64 MB
3000+ Series PID Quick Start Guide - IT
734.57 KB
7/15/2021
PDF 734.57 KB
3000+ Series PID Quick Start Guide - RU
784.44 KB
7/15/2021
PDF 784.44 KB
3G PID User Guide - EN
7.52 MB
7/15/2021
PDF 7.52 MB
3G PID User Guide - RU
7.71 MB
7/15/2021
PDF 7.71 MB
3000+ Series PID Quick Start Guide - DE
739.46 KB
7/15/2021
PDF 739.46 KB
3000+ Series PID Quick Start Guide - EN
737 KB
7/15/2021
PDF 737 KB
3000+ Series PID Quick Start Guide - FR
736.61 KB
7/15/2021
PDF 736.61 KB
3G PID User Guide - PT
7.58 MB
7/15/2021
PDF 7.58 MB
3G PID User Guide - FR
7.57 MB
7/15/2021
PDF 7.57 MB
3000+ Series PID Quick Start Guide - PT
736.66 KB
7/15/2021
PDF 736.66 KB
3G PID User Guide - ES
7.53 MB
7/15/2021
PDF 7.53 MB
Software
Name
Description
File Size
Date
Size
ppbRAE3000+ PGM-7340 V2.22A.35
963.7 KB
7/15/2021
963.7 KB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
7/15/2021
PDF 911.54 KB
3GPID+ Technical Note
436.09 KB
7/15/2021
PDF 436.09 KB
A Guideline for Pid Instrument Response
1.45 MB
11/2/2021
PDF 1.45 MB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
7/15/2021
PDF 950.72 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
7/15/2021
PDF 820.7 KB
Technical Note 170 USB To Serial Port Adapter
1.26 MB
7/15/2021
PDF 1.26 MB
Lithium-Ion Batteries Technical Note 166
926.7 KB
7/15/2021
PDF 926.7 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
7/15/2021
PDF 930.69 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
7/15/2021
PDF 984.3 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
PDF 788.83 KB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
7/15/2021
PDF 839.32 KB
Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
813.81 KB
10/8/2021
PDF 813.81 KB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
790.79 KB
7/15/2021
PDF 790.79 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
10/8/2021
PDF 1.09 MB
Application Note
Name
Description
File Size
Date
Size
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
7/15/2021
PDF 964.88 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
PDF 655.59 KB
Application Note 214: Environmental Applications For PIDs
836.36 KB
7/15/2021
PDF 836.36 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
PDF 1.1 MB
Others
Name
Description
File Size
Date
Size
3G PID User Guide - EN
4.11 MB
7/15/2021
PDF 4.11 MB
Name
Description
File Size
Date
Size
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
7/15/2021
PDF 911.54 KB
3GPID+ Technical Note
436.09 KB
7/15/2021
PDF 436.09 KB
3G PID User's Guide - PL
3.91 MB
7/15/2021
PDF 3.91 MB
3G PID User Guide - IT
7.57 MB
7/15/2021
PDF 7.57 MB
3G PID User Guide - NL
7.5 MB
7/15/2021
PDF 7.5 MB
3000+ Series PID Quick Start Guide - NL
736.75 KB
7/15/2021
PDF 736.75 KB
A Guideline for Pid Instrument Response
1.45 MB
11/2/2021
PDF 1.45 MB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
7/15/2021
PDF 950.72 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
7/15/2021
PDF 820.7 KB
3000+ Series PID Quick Start Guide - ES
735.47 KB
7/15/2021
PDF 735.47 KB
Technical Note 170 USB To Serial Port Adapter
1.26 MB
7/15/2021
PDF 1.26 MB
ppbRAE 3000 + Data Sheet - EN
2.68 MB
7/15/2021
PDF 2.68 MB
3G PID User Guide - DE
7.64 MB
7/15/2021
PDF 7.64 MB
3000+ Series PID Quick Start Guide - IT
734.57 KB
7/15/2021
PDF 734.57 KB
Lithium-Ion Batteries Technical Note 166
926.7 KB
7/15/2021
PDF 926.7 KB
ppbRAE 3000 + Data Sheet - NL
343.12 KB
7/15/2021
PDF 343.12 KB
3000+ Series PID Quick Start Guide - RU
784.44 KB
7/15/2021
PDF 784.44 KB
3G PID User Guide - EN
7.52 MB
7/15/2021
PDF 7.52 MB
3G PID User Guide - RU
7.71 MB
7/15/2021
PDF 7.71 MB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
7/15/2021
PDF 930.69 KB
3000+ Series PID Quick Start Guide - DE
739.46 KB
7/15/2021
PDF 739.46 KB
3000+ Series PID Quick Start Guide - EN
737 KB
7/15/2021
PDF 737 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
7/15/2021
PDF 984.3 KB
ppbRAE 3000 + Data Sheet - PT
344.72 KB
7/15/2021
PDF 344.72 KB
ppbRAE 3000 + Data Sheet - RU
401.41 KB
7/15/2021
PDF 401.41 KB
3000+ Series PID Quick Start Guide - FR
736.61 KB
7/15/2021
PDF 736.61 KB
3G PID User Guide - PT
7.58 MB
7/15/2021
PDF 7.58 MB
3G PID User Guide - EN
4.11 MB
7/15/2021
PDF 4.11 MB
ppbRAE 3000 + Data Sheet - DE
345.82 KB
7/15/2021
PDF 345.82 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
PDF 788.83 KB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
7/15/2021
PDF 839.32 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
7/15/2021
PDF 964.88 KB
Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
813.81 KB
10/8/2021
PDF 813.81 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
PDF 655.59 KB
3G PID User Guide - FR
7.57 MB
7/15/2021
PDF 7.57 MB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
790.79 KB
7/15/2021
PDF 790.79 KB
ppbRAE 3000 + Data Sheet - IT
342.08 KB
7/15/2021
PDF 342.08 KB
3000+ Series PID Quick Start Guide - PT
736.66 KB
7/15/2021
PDF 736.66 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
10/8/2021
PDF 1.09 MB
3G PID User Guide - ES
7.53 MB
7/15/2021
PDF 7.53 MB
ppbRAE 3000 + Data Sheet - ES
343.33 KB
7/15/2021
PDF 343.33 KB
Application Note 214: Environmental Applications For PIDs
836.36 KB
7/15/2021
PDF 836.36 KB
ppbRAE 3000 + Data Sheet - FR
344.63 KB
7/15/2021
PDF 344.63 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
PDF 1.1 MB
ppbRAE3000+ PGM-7340 V2.22A.35
963.7 KB
7/15/2021
963.7 KB
Image
SKU
Description
alt
059-C306-400
ppbRAE 3K/PID9.8/ALK/NO-WLS/ATX
alt
059-C116-300
ppbRAE 3K/PID10.6/RE Li-Ion/NO-WLS/ATX
alt
059-C11E-300
ppbRAE 3K/PID10.6/RE Li-Ion/BLE/ATEX
alt
059-C110-000
PPBRAE 3000+ MONITOR.10.6EV,1/2".UL LI-ION BATTERY.NON WIRELESS.MONITOR ONLY
alt
059-C116-000
ppbRAE 3000+, none-Wireless, ATEX/IECEx, PID 10.6 eV lamp 1/2″ for Total VOC mode only, Rechargeable Li-Ion battery, universal adapter, Monitor only
alt
059-C110-100
PPBRAE 3000+ MONITOR.10.6EV,1/2".UL LI-ION BATTERY.NON WIRELESS.ACCS,CAL KIT,GAS & REGULATOR
alt
059-C316-300
ppbRAE 3K/PID9.8/RE Li-Ion/NO-WLS/ATX
alt
059-C106-400
ppbRAE 3K/PID10.6/ALK/NO-WLS/ATX
alt
059-9140-000
Hard Case Kit, ppbRAE3000+, universal accessories without gas and flow regulator
alt
059-C118-300
ppbRAE 3K/PID10.6/RE Li-Ion/W-868/ATX