Increase worker safety and improve incident response during compliance-related procedures and periodic testing with this rugged, easy-to-maintain device. The ToxiRAE Pro CO2 is the only wireless CO2 single gas monitor available on the market. The ToxiRAE Pro CO2 is a personal detector that keeps people aware of carbon dioxide levels and facilitates remote monitoring of those readings from a central command station. The ToxiRAE Pro CO2 includes a replaceable filter and sensor, rechargeable lithium-ion battery, and automated bump testing and calibration to make it easy to use and maintain.Features and Benefits:
- First of its kind wireless personal carbon dioxide monitor
- Wireless remote access for centralized monitoring
- Built-in man down alarm
- Rechargeable lithium-ion battery
- Automatic bump testing and calibration with AutoRAE 2
- 5-way local and remote alarm capabilities
- Large display
- Readily enables to communicate with Motorola MOTOTRBO
- Emergency Response
- Indoor Air Quality
- Plant Shutdown & Turn-Around
- Worker Exposure
Others
- Alarm Type
- Audible, Visual, Vibrating
- Sensor Range
- CO2 (0-50000ppm)
- Minimum Temperature
- -20 degree Celsius
- -4 degree Fahrenheit
- Benefits
- • Wireless elevates safety to the next level
- Humidity Range
- 0%-95%
- Sub-Category
- Single-Gas
- Maximum Temperature
- 55 degree Celsius
- 131 degree Fahrenheit
- Weight
- 220 gram
- 7.76 ounce av [Invisible]
- Standards
- CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I,
- Brand
- RAE
- Wireless Technology
- MESH
- Gas Type
- CO2
- Datalogging
- Three-month capacity
- Battery Run Time
- 11
- Warranty
- Four years on O2 sensor
- Ingress Protection
- IP65
- User Options
- - Wireless remote alarm notification; audible (95 dB @ 30 cm),
- Instrument Size
- 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
Others
- Alarm Type
- Audible, Visual, Vibrating
- Sensor Range
- CO2 (0-50000ppm)
- Minimum Temperature
- -20 degree Celsius
- -4 degree Fahrenheit
- Benefits
- • Wireless elevates safety to the next level
- Humidity Range
- 0%-95%
- Sub-Category
- Single-Gas
- Maximum Temperature
- 55 degree Celsius
- 131 degree Fahrenheit
- Weight
- 220 gram
- 7.76 ounce av [Invisible]
- Standards
- CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I,
- Brand
- RAE
- Wireless Technology
- MESH
- Gas Type
- CO2
- Datalogging
- Three-month capacity
- Battery Run Time
- 11
- Warranty
- Four years on O2 sensor
- Ingress Protection
- IP65
- User Options
- - Wireless remote alarm notification; audible (95 dB @ 30 cm),
- Instrument Size
- 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
- Alarm Type : Audible, Visual, Vibrating
- Sensor Range : CO2 (0-50000ppm)
- Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
- Benefits : • Wireless elevates safety to the next level
- Humidity Range : 0%-95%
- Sub-Category : Single-Gas
- Maximum Temperature : 55 degree Celsius|131 degree Fahrenheit
- Weight : 220 gram|7.76 ounce av [Invisible]
- Standards : CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I,
- Brand : RAE
- Wireless Technology : MESH
- Gas Type : CO2
- Datalogging : Three-month capacity
- Battery Run Time : 11
- Warranty : Four years on O2 sensor
- Ingress Protection : IP65
- User Options : - Wireless remote alarm notification; audible (95 dB @ 30 cm),
- Instrument Size : 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
Data Sheet
Name
Description
File Size
Date
Size
Manuals and Guides
Name
Description
File Size
Date
Size
Brochure
Name
Description
File Size
Date
Size
MSI-Honeywell Connected Safety Solution
441.3 KB
5/7/2021
PDF 441.3 KB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
5/5/2021
PDF 839.32 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
5/5/2021
PDF 884.37 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
5/5/2021
PDF 795.02 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 222: Carbon Monoxide & Natural Gas Detection For Fire Department Engine Companies
1.17 MB
5/5/2021
PDF 1.17 MB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
5/5/2021
PDF 901.23 KB
Others
Name
Description
File Size
Date
Size
Techninal Note 123_Special Diagnostic Modes For RAE Systems Instruments_10-05
899.77 KB
12/4/2020
PDF 899.77 KB
Name
Description
File Size
Date
Size
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
5/5/2021
PDF 839.32 KB
Techninal Note 123_Special Diagnostic Modes For RAE Systems Instruments_10-05
899.77 KB
12/4/2020
PDF 899.77 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
5/5/2021
PDF 884.37 KB
Application Note 222: Carbon Monoxide & Natural Gas Detection For Fire Department Engine Companies
1.17 MB
5/5/2021
PDF 1.17 MB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
5/5/2021
PDF 901.23 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
5/5/2021
PDF 795.02 KB
MSI-Honeywell Connected Safety Solution
441.3 KB
5/7/2021
PDF 441.3 KB
Image
SKU
Description
G02-0009-000