https://sps.honeywell.com/us/en/search-results.html
Outage Notification: On Saturday, June 5,12:30-2:30 p.m. EDT (6:30 to 8:30 p.m. UDT), this website will undergo planned maintenance. Thank you for your patience.

Board Mount Pressure Sensors

Basic NBP Series

Uncompensated. Low pressure. Absolute, gage. mV output. DIP, leadless SMT, SMT. Accuracy: ±0.25 %FSS BFSL. Cost effective

Distributor Inventory

Pressure Ranges:
  • TBP Series: 60 mbar to 10 bar | 6 kPa to 1 MPa | 1 psi to 150 psi, millivolt analog output
  • NBP Series: 60 mbar to 10 bar | 1 psi to 150 psi, millivolt analog output
Description

Honeywell's Basic Board Mount Pressure Sensors, TBP Series and NBP Series, are designed for food grade and non-food grade potential medical and industrial applications. These unamplified, piezoresistive silicon pressure sensors provide a ratiometric output and are either temperature compensated (TBP Series) or uncompensated (NBP Series).

TBP Series
  • Temperature compensated and unamplified.
  • Compensation makes it easier to integrate the sensor into a system by minimizing the need to calibrate the system over temperature on a regular basis: offers reduced part-to-part variation.
  • Offers infinite resolution of the pressure signal.
  • Compensated temperature range is 0°C to 85°C [-32°F to 185°F].
NBP Series
  • Uncompensated and unamplified.
  • Is often ideal for customers who want to do their own compensation, calibration and amplification in order to make use of the maximum resolution of the bare sensor output, leveraging any algorithm needed for the application.
  • Offers infinite resolution of the pressure signal.

These products are available in numerous package styles and mounting options, making it easier for device manufacturers to integrate the product into their applications. They are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases, and for non-corrosive, non-ionic liquids when the silicone gel coating option is selected. All products are designed and manufactured according to ISO 9001 and are NSF certified.

Value to Customers
  • Cost-competitive pressure sensing solution.
  • Smaller when compared to many similar products, occupying less space on the printed circuit board (PCB) and typically allowing for easier placement on PCBs or in small devices.
  • Performs in many tough environments with dry and wetted media.
  • Numerous options simplify integration into the device manufacturer's application.
  • Food Safety Certification for North America, Europe and Asia.

Others

  • Shock
    • MIL-STD-202F, Method 213B, Condition F (100 g, 6 ms duration)
  • Operating Temperature
    • -40 °C to 125 °C [-40 °F to 257 °F]
  • Measurement Type
    • Gage
    • Absolute
  • Vibration
    • MIL-STD-202F, Method 214A, Condition 1E (15 g, 10 Hz to 2 kHz)
  • Pressure Range
    • 0 psi to 15 psi
    • 0 psi to 150 psi
    • 0 psi to 100 psi
    • 0 psi to 1 psi
    • 0 psi to 60 psi
    • 0 psi to 30 psi
    • 0 psi to 5 psi
  • Input Resistance
    • 3.0 kOhm typ.
  • Supply Current
    • 1.5 mA typ.
  • Port Style
    • AN: single axial barbed port
    • LN: single axial barbless port
    • PN: low-profile port
  • Accuracy (Best Fit Straight Line)
    • ±0.25%
  • Package Type
    • Leadless SMT
    • SMT
    • DIP
  • Media Compatibility
    • Non-corrosive, non-ionic gases, such as air and other dry gases, and for non-corrosive, non-ionic liquids.
  • Temperature Compensation
    • No
  • Signal Conditioning
    • Unamplified
  • Output
    • Analog
  • Life
    • 1 million pressure cycles min.
  • Supply Voltage
    • 5 Vdc
  • Series Name
    • Basic NBP
  • Output Calibration
    • No
  • Storage Temperature
    • -40 °C to 125 °C [-40 °F to 257 °F]

Others

  • Shock
    • MIL-STD-202F, Method 213B, Condition F (100 g, 6 ms duration)
  • Operating Temperature
    • -40 °C to 125 °C [-40 °F to 257 °F]
  • Measurement Type
    • Gage
    • Absolute
  • Vibration
    • MIL-STD-202F, Method 214A, Condition 1E (15 g, 10 Hz to 2 kHz)
  • Pressure Range
    • 0 psi to 15 psi
    • 0 psi to 150 psi
    • 0 psi to 100 psi
    • 0 psi to 1 psi
    • 0 psi to 60 psi
    • 0 psi to 30 psi
    • 0 psi to 5 psi
  • Input Resistance
    • 3.0 kOhm typ.
  • Supply Current
    • 1.5 mA typ.
  • Port Style
    • AN: single axial barbed port
    • LN: single axial barbless port
    • PN: low-profile port
  • Accuracy (Best Fit Straight Line)
    • ±0.25%
  • Package Type
    • Leadless SMT
    • SMT
    • DIP
  • Media Compatibility
    • Non-corrosive, non-ionic gases, such as air and other dry gases, and for non-corrosive, non-ionic liquids.
  • Temperature Compensation
    • No
  • Signal Conditioning
    • Unamplified
  • Output
    • Analog
  • Life
    • 1 million pressure cycles min.
  • Supply Voltage
    • 5 Vdc
  • Series Name
    • Basic NBP
  • Output Calibration
    • No
  • Storage Temperature
    • -40 °C to 125 °C [-40 °F to 257 °F]
  • Shock : MIL-STD-202F, Method 213B, Condition F (100 g, 6 ms duration)
  • Operating Temperature : -40 °C to 125 °C [-40 °F to 257 °F]
  • Measurement Type : Gage|Absolute
  • Vibration : MIL-STD-202F, Method 214A, Condition 1E (15 g, 10 Hz to 2 kHz)
  • Pressure Range : 0 psi to 15 psi|0 psi to 150 psi|0 psi to 100 psi|0 psi to 1 psi|0 psi to 60 psi|0 psi to 30 psi|0 psi to 5 psi
  • Input Resistance : 3.0 kOhm typ.
  • Supply Current : 1.5 mA typ.
  • Port Style : AN: single axial barbed port|LN: single axial barbless port|PN: low-profile port
  • Accuracy (Best Fit Straight Line) : ±0.25%
  • Package Type : Leadless SMT|SMT|DIP
  • Media Compatibility : Non-corrosive, non-ionic gases, such as air and other dry gases, and for non-corrosive, non-ionic liquids.
  • Temperature Compensation : No
  • Signal Conditioning : Unamplified
  • Output : Analog
  • Life : 1 million pressure cycles min.
  • Supply Voltage : 5 Vdc
  • Series Name : Basic NBP
  • Output Calibration : No
  • Storage Temperature : -40 °C to 125 °C [-40 °F to 257 °F]
Data Sheet
Name
Description
File Size
Date
Size
Basic Board Mount Pressure Sensors: TBP Series, Comp/UnAmp; NBP Series, Uncomp/Unamp Datasheet
2.94 MB
5/24/2021
PDF 2.94 MB
Manuals and Guides
Name
Description
File Size
Date
Size
Airflow sensors contain advanced microstructure technology to provide a sensitive and fast response to flow, amount/direction of air or other gases. Potential applications include HVAC, gas metering, chromatography, vent hoods, and medical equipment.
4.14 MB
5/24/2021
PDF 4.14 MB
Board Mount Pressure Sensors Selection Guide
1.15 MB
5/24/2021
PDF 1.15 MB
Installation Instructions
Name
Description
File Size
Date
Size
Basic Board Mount Pressure Sensors: TBP Series and NBP Series Installation Instructions
2.3 MB
5/24/2021
PDF 2.3 MB
Brochure
Name
Description
File Size
Date
Size
Embedded Products in Hospital Applications
4.7 MB
5/24/2021
PDF 4.7 MB
Technical Note
Name
Description
File Size
Date
Size
Pressure Sensor Surface Mount (SMT) Guidelines
1.69 MB
5/24/2021
PDF 1.69 MB
Pressure Sensor Glossary of Terms
129.79 KB
5/24/2021
PDF 129.79 KB
Energy and Environmental Design Trends
828.15 KB
5/24/2021
PDF 828.15 KB
Pressure or Airflow Sensors?
553.46 KB
5/24/2021
PDF 553.46 KB
Pneumatic Interface Recommendations for Honeywell Basic Board Mount Pressure Sensors
142.04 KB
5/24/2021
PDF 142.04 KB
Output Signal Adjustment and Temperature Compensation for Honeywell Basic Board Mount Pressure Sensors
355.73 KB
5/24/2021
PDF 355.73 KB
Industrial Product Line Card
1.84 MB
5/24/2021
PDF 1.84 MB
White Paper
Name
Description
File Size
Date
Size
The Economics of Accuracy in Low-Cost, High-Volume Medical Applications
2.25 MB
5/24/2021
PDF 2.25 MB
Application Note
Name
Description
File Size
Date
Size
Solutions for Oxygen Concentrators
2.3 MB
5/24/2021
PDF 2.3 MB
Sensors and Switches: Solutions for Medical Applications
495.28 KB
5/24/2021
PDF 495.28 KB
Basic Board Mount Pressure Sensors: TBP Series and NBP Series
1.02 MB
5/24/2021
PDF 1.02 MB
Sensor Use in Building Energy Conservation
2.53 MB
5/24/2021
PDF 2.53 MB
Product Photo
Name
Description
File Size
Date
Size
Basic NBP Series, Basic TBP Series Product Photos - grouped
1.15 MB
6/1/2021
1.15 MB
Name
Description
File Size
Date
Size
Solutions for Oxygen Concentrators
2.3 MB
5/24/2021
PDF 2.3 MB
The Economics of Accuracy in Low-Cost, High-Volume Medical Applications
2.25 MB
5/24/2021
PDF 2.25 MB
Sensors and Switches: Solutions for Medical Applications
495.28 KB
5/24/2021
PDF 495.28 KB
Pressure Sensor Surface Mount (SMT) Guidelines
1.69 MB
5/24/2021
PDF 1.69 MB
Pressure Sensor Glossary of Terms
129.79 KB
5/24/2021
PDF 129.79 KB
Energy and Environmental Design Trends
828.15 KB
5/24/2021
PDF 828.15 KB
Airflow sensors contain advanced microstructure technology to provide a sensitive and fast response to flow, amount/direction of air or other gases. Potential applications include HVAC, gas metering, chromatography, vent hoods, and medical equipment.
4.14 MB
5/24/2021
PDF 4.14 MB
Pressure or Airflow Sensors?
553.46 KB
5/24/2021
PDF 553.46 KB
Pneumatic Interface Recommendations for Honeywell Basic Board Mount Pressure Sensors
142.04 KB
5/24/2021
PDF 142.04 KB
Basic Board Mount Pressure Sensors: TBP Series, Comp/UnAmp; NBP Series, Uncomp/Unamp Datasheet
2.94 MB
5/24/2021
PDF 2.94 MB
Basic Board Mount Pressure Sensors: TBP Series and NBP Series Installation Instructions
2.3 MB
5/24/2021
PDF 2.3 MB
Output Signal Adjustment and Temperature Compensation for Honeywell Basic Board Mount Pressure Sensors
355.73 KB
5/24/2021
PDF 355.73 KB
Basic Board Mount Pressure Sensors: TBP Series and NBP Series
1.02 MB
5/24/2021
PDF 1.02 MB
Sensor Use in Building Energy Conservation
2.53 MB
5/24/2021
PDF 2.53 MB
Board Mount Pressure Sensors Selection Guide
1.15 MB
5/24/2021
PDF 1.15 MB
Basic NBP Series, Basic TBP Series Product Photos - grouped
1.15 MB
6/1/2021
1.15 MB
Industrial Product Line Card
1.84 MB
5/24/2021
PDF 1.84 MB
Embedded Products in Hospital Applications
4.7 MB
5/24/2021
PDF 4.7 MB