Industrial Pressure Sensors
MIP Series
Heavy Duty, Media-Isolated Pressure Transducers 1 bar to 12 bar | 15 psi to 175 psi
The MIP Series offers a heavy duty, media-isolated pressure transducer in a compact, stainless steel construction for use with a wide range of media including aggressive fluids and water. The MIP Series provides a cost-competitive solution for wide-ranging potential applications in tough environments.
Value to Customers
- Total Error Band (TEB) ±0.75 %FSS to ±1.0 %FSS (Full Scale Span) from -40°C to 125°C: Provides true measurement performance over the compensated temperature range; small error promotes system uptime and efficiency.
- EMC performance: Operates reliably in the presence of electromagnetic fields, such as wireless signals, RF communication, and electrical devices.
- Hermetically welded design supports almost any media without the use of an internal seal. The sensors are designed to be used in harsh environments that see aggressive media.
Differentiation
- Diagnostics: Beneficial in applications where the sensor functionality and the need to know internal or external failure modes is critical.
- Great customer value: Multiple configuration possibilities provide flexibility of use in the application with no up front NRE or tooling charges.
- Durable: Provides the toughenvironmental capabilities needed, including long-term stability, insulation resistance and dielectric strength, external freeze-thaw resistance and EMC performance.
Features
- Rugged, stainless steel construction
- Ratiometric output: 0.5 Vdc to 4.5 Vdc
- Operating temperature: -40°C to 125°C
- Total Error Band ±0.75 %FSS to ±1.0 %FSS (-40°C to 125°C)
- Industry-leading accuracy: ±0.15 %FSS BFSL
- Long term stability: ±0.25 %FSS
- Radiated immunity: 100 V/m
- Drinking water approval: NSF/ANSI/CAN 61
- CE, RoHS, REACH compliant
- Mis-wiring protection
- Over voltage protection ±40 Vdc
Potential Applications
- Industrial: pumps (water, hydraulic fluids), compressors (compressed air), process (food, beverage, oil, gas, steam)
- HVAC/R: refrigerants (butane, propane, ammonia, CO2, R134A, R407C, R410A, R448A/Solstice® N40, R32 and R1234ze, R1234yf, glycol + water
- Transportation: gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG
- Medical: O2, N2, CO2, N2O, air
Others
- Burst Pressure
- 3000 psi
- 207 bar
- Response Time
- 1 ms (10% to 90% step change in pressure)
- Storage Temperature
- -40°C to 125°C [-40°F to 257°F]
- Shock
- 100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C)
- Operating Temperature
- -40°C to 125°C [-40°F to 257°F]
- Measurement Type
- Absolute
- Sealed gage
- Vibration
- 20 G sweep, 10 Hz to 2000 Hz (at 25°C)
- Overpressure
- 24 bar
- 348 psi
- 6 bar
- 87 psi
- Pressure Range
- 1bar to 12 bar
- 15 psi to 175 psi
- Output Type
- Ratiometric: 5.0 Vdc to 4.5 Vdc
- Supply Current
- 6.5 mA ±1 mA
- Port Style
- G 1/4 A-G (ISO 1179-3)
- M12 x 1.5 (ISO 6149-3)
- G 1/4 A-L (ISO 1179-2)
- 7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512)
- 1/4-18 NPT (ANSI/ASME B1.20.1)
- 1/8-27 NPT (ANSI/ASME B1.20.1)
- Electrical Connection
- Metri-Pack 150, Standard (UL V-0)
- Media Compatibility
- <p>The MIP Series is compatible with water, hydraulic fluids, compressed air, food, beverage, oil, gas, steam; refrigerants (butane, propane, ammonia, CO<sub>2</sub>, R134A, R407C, R410A, R448A/Solstice® N40, R32 and R1234ze, R1234yf, glycol + water); gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG; O<sub>2</sub>, N<sub>2</sub>, CO<sub>2</sub>, N<sub>2</sub>,O<sub>2</sub>, air.</p>
- Compensated Temperature Range
- -40°C to 125°C [-40°F to 257°F]
- Accuracy
- ±0.15 %FSS BFSL
- Temperature Compensation
- Yes
- Signal Conditioning
- Amplified
- Life
- Greater than 10 million full scale pressure cycles
- Supply Voltage
- 4.75 V to 5.25 V
- Agency Approvals and Standards
- Drinking water approval: NSF/ANSI/CAN 61; CE, RoHS, REACH compliant
- Series Name
- MIP
- Total Error Band
- ±0.75 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])
- ±1.0 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])
- ±1.00 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])
Others
- Burst Pressure
- 3000 psi
- 207 bar
- Response Time
- 1 ms (10% to 90% step change in pressure)
- Storage Temperature
- -40°C to 125°C [-40°F to 257°F]
- Shock
- 100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C)
- Operating Temperature
- -40°C to 125°C [-40°F to 257°F]
- Measurement Type
- Absolute
- Sealed gage
- Vibration
- 20 G sweep, 10 Hz to 2000 Hz (at 25°C)
- Overpressure
- 24 bar
- 348 psi
- 6 bar
- 87 psi
- Pressure Range
- 1bar to 12 bar
- 15 psi to 175 psi
- Output Type
- Ratiometric: 5.0 Vdc to 4.5 Vdc
- Supply Current
- 6.5 mA ±1 mA
- Port Style
- G 1/4 A-G (ISO 1179-3)
- M12 x 1.5 (ISO 6149-3)
- G 1/4 A-L (ISO 1179-2)
- 7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512)
- 1/4-18 NPT (ANSI/ASME B1.20.1)
- 1/8-27 NPT (ANSI/ASME B1.20.1)
- Electrical Connection
- Metri-Pack 150, Standard (UL V-0)
- Media Compatibility
- <p>The MIP Series is compatible with water, hydraulic fluids, compressed air, food, beverage, oil, gas, steam; refrigerants (butane, propane, ammonia, CO<sub>2</sub>, R134A, R407C, R410A, R448A/Solstice® N40, R32 and R1234ze, R1234yf, glycol + water); gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG; O<sub>2</sub>, N<sub>2</sub>, CO<sub>2</sub>, N<sub>2</sub>,O<sub>2</sub>, air.</p>
- Compensated Temperature Range
- -40°C to 125°C [-40°F to 257°F]
- Accuracy
- ±0.15 %FSS BFSL
- Temperature Compensation
- Yes
- Signal Conditioning
- Amplified
- Life
- Greater than 10 million full scale pressure cycles
- Supply Voltage
- 4.75 V to 5.25 V
- Agency Approvals and Standards
- Drinking water approval: NSF/ANSI/CAN 61; CE, RoHS, REACH compliant
- Series Name
- MIP
- Total Error Band
- ±0.75 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])
- ±1.0 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])
- ±1.00 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])
- Burst Pressure : 3000 psi|207 bar
- Response Time : 1 ms (10% to 90% step change in pressure)
- Storage Temperature : -40°C to 125°C [-40°F to 257°F]
- Shock : 100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C)
- Operating Temperature : -40°C to 125°C [-40°F to 257°F]
- Measurement Type : Absolute|Sealed gage
- Vibration : 20 G sweep, 10 Hz to 2000 Hz (at 25°C)
- Overpressure : 24 bar|348 psi|6 bar|87 psi
- Pressure Range : 1bar to 12 bar|15 psi to 175 psi
- Output Type : Ratiometric: 5.0 Vdc to 4.5 Vdc
- Supply Current : 6.5 mA ±1 mA
- Port Style : G 1/4 A-G (ISO 1179-3)|M12 x 1.5 (ISO 6149-3)|G 1/4 A-L (ISO 1179-2)|7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512)|1/4-18 NPT (ANSI/ASME B1.20.1)|1/8-27 NPT (ANSI/ASME B1.20.1)
- Electrical Connection : Metri-Pack 150, Standard (UL V-0)
- Media Compatibility :
The MIP Series is compatible with water, hydraulic fluids, compressed air, food, beverage, oil, gas, steam; refrigerants (butane, propane, ammonia, CO2, R134A, R407C, R410A, R448A/Solstice® N40, R32 and R1234ze, R1234yf, glycol + water); gasoline, diesel fuel, engine oil, brake fluid, coolants, CNG; O2, N2, CO2, N2,O2, air.
- Compensated Temperature Range : -40°C to 125°C [-40°F to 257°F]
- Accuracy : ±0.15 %FSS BFSL
- Temperature Compensation : Yes
- Signal Conditioning : Amplified
- Life : Greater than 10 million full scale pressure cycles
- Supply Voltage : 4.75 V to 5.25 V
- Agency Approvals and Standards : Drinking water approval: NSF/ANSI/CAN 61; CE, RoHS, REACH compliant
- Series Name : MIP
- Total Error Band : ±0.75 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])|±1.0 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])|±1.00 %FSS BFSL (-40°C to 125°C [-40°F to 275°F])