Honeywell's PX3 Series Heavy Duty Pressure Transducers use piezoresistive sensing technology with ASIC (Application Specific Integrated Circuit) signal conditioning in a brass housing and Metri-Pack 150, DIN, or cable harness electrical connections. The PX3 Series is calibrated and temperature compensated from -40°C to 125°C [-40°F to 257°F].

The PX3 Series is available in two pressure ranges:
  • 1 bar to 50 bar
  • 15 psi to 700 psi
Value to Customers
  • Total Error Band (TEB) ±1.0 %FSS from -20°C to 85°C: Provides indication of the sensor̵7:s true measurement performance over a specified temperature range: small error promotes system uptime and efficiency.
  • Higher insulation resistance and dielectric strength: Protects the user and sensor in high over-voltage situations, and ensures that the device is compliant with industry standards.
  • Higher EMC performance: Operates more reliably in the presence of electro-magnetic fields, such as near wireless signals, RF communication, and electrical devices.
  • Higher external freeze/thaw resistance: Survives exposure to frost, commonly found in refrigeration systems.
  • Reduced current consumption: Helps to reduce energy costs, and enhances product life if used in battery driven systems.
  • Media compatibility: Common HFC (hydrofluorocarbon) refrigerants (R410A and R134A), next generation low global warming potential (GWP) refrigerants (R448A/Solstice® N40, R32 and R1234ZE), engine oil, petroleum-based hydraulic fluids, brake fluids (DOT3), and dry air. For ammonia and other corrosive media, see Honeywell's SPT Series.
Differentiation
  • Optional diagnostics mode: Beneficial in applications where the sensor functionality and the need to know internal or external failure modes is critical.
  • Great customer value: Multiple configuration possibilities provide flexibility of use in the application with no upfront NRE or tooling charges.
  • Durable: Provides the tough environmental specifications needed, including insulation resistance and dielectric strength, external freeze-thaw resistance, and EMC performance.
  • 4 mA to 20 mA output is temperature compensated up to 125°C.

Others

  • Shock
    • 100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C)
  • Burst Pressure
    • 51 bar
    • 103 bar
    • 750 psi
    • 80 bar
    • 1500 psi
    • 1150 psi
  • Operating Temperature
    • -40°C to 125°C [-40°F to 257°F]
  • Measurement Type
    • Sealed gage
    • Absolute
  • Vibration
    • 20 G sweep, 10 Hz to 2000 Hz (at 25°C)
  • Overpressure
    • 1000 psi
    • 31 bar
    • 69 bar
    • 450 psi
    • 32 bar
  • Pressure Range
    • 0 bar to 30 bar
    • 0 bar to 25 bar
    • 0 bar to 46 bar
    • 0 bar to 40 bar
    • 0 psi to 200 psi
    • 0 psi to 100 psi
    • 0 psi to 150 psi
    • 0 bar to 8 bar
    • 0 psi to 500 psi
    • 0 bar to 16 bar
    • 0 psi to 667 psi
    • 0 bar to 20 bar
    • 0 bar to 10 bar
    • 0 psi to 300 psi
    • 0 bar to 50 bar
    • 0 psi to 250 psi
    • 0 bar to 35 bar
  • Output Type
    • Ratiometric: 5.0 Vdc to 4.5 Vdc
    • Current: 4 mA to 20 mA
  • Response Time
    • <2 ms
  • Port Style
    • 1/8-27 NPT (ANSI/ASME B1.20.1)
    • 1/4-18 NPT (ANSI/ASME B1.20.1)
    • 7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512)
    • G 1/4 A-G (ISO 1179-3)
  • Electrical Connection
    • Cable PVC, 2,0 m [6.6 ft]
    • Cable, XLPE, 2.0 m [6.6 ft]
    • Metri-Pack 150, Standard (UL V-0)
    • Cable PVC, 1.0 m [3.2 ft]
    • Cable PVC, 3,0 m [9.8 ft]
  • Media Compatibility
    • <p>The PX3 Series is compatible with common HFC (hydrofluorocarbon) refrigerants such as R410A and R134A, next generation low global warming potential (GWP) refrigerants such as R448A (Solstice® N40), R32 and R1234ZE, engine oil, petroleum-based hydraulic fluids, DOT 3 brake fluid, and dry air. For ammonia and other corrosive media, see Honeywell’s SPT Series.</p> <p>The PX3 Series is not recommended for use with media involving water, saturated air such as steam and vapor, and ammonia.</p>
  • Compensated Temperature Range
    • -40°C to 125°C [-40°F to 257°F]
  • Accuracy
    • ±0.25 %FSS
  • Temperature Compensation
    • Yes
  • Signal Conditioning
    • Amplified
  • Life
    • Greater than 10 million full scale pressure cycles over the calibrated pressure range
  • Supply Voltage
    • 8 Vdc to 30 Vdc (-40°C to 100°C)
    • 4.75 V to 5.25 V
  • Series Name
    • PX3
  • Agency Approvals and Standards
    • IP67
    • IP69K
  • Total Error Band
    • ±1.0 %FSS (-20°C to 85°C [-4°F to 185°F]), ±2.0 %FSS (<-20°C, >85°C [<-4°F, >185°F])
  • Storage Temperature
    • -40°C to 125°C [-40°F to 257°F]

Others

  • Shock
    • 100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C)
  • Burst Pressure
    • 51 bar
    • 103 bar
    • 750 psi
    • 80 bar
    • 1500 psi
    • 1150 psi
  • Operating Temperature
    • -40°C to 125°C [-40°F to 257°F]
  • Measurement Type
    • Sealed gage
    • Absolute
  • Vibration
    • 20 G sweep, 10 Hz to 2000 Hz (at 25°C)
  • Overpressure
    • 1000 psi
    • 31 bar
    • 69 bar
    • 450 psi
    • 32 bar
  • Pressure Range
    • 0 bar to 30 bar
    • 0 bar to 25 bar
    • 0 bar to 46 bar
    • 0 bar to 40 bar
    • 0 psi to 200 psi
    • 0 psi to 100 psi
    • 0 psi to 150 psi
    • 0 bar to 8 bar
    • 0 psi to 500 psi
    • 0 bar to 16 bar
    • 0 psi to 667 psi
    • 0 bar to 20 bar
    • 0 bar to 10 bar
    • 0 psi to 300 psi
    • 0 bar to 50 bar
    • 0 psi to 250 psi
    • 0 bar to 35 bar
  • Output Type
    • Ratiometric: 5.0 Vdc to 4.5 Vdc
    • Current: 4 mA to 20 mA
  • Response Time
    • <2 ms
  • Port Style
    • 1/8-27 NPT (ANSI/ASME B1.20.1)
    • 1/4-18 NPT (ANSI/ASME B1.20.1)
    • 7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512)
    • G 1/4 A-G (ISO 1179-3)
  • Electrical Connection
    • Cable PVC, 2,0 m [6.6 ft]
    • Cable, XLPE, 2.0 m [6.6 ft]
    • Metri-Pack 150, Standard (UL V-0)
    • Cable PVC, 1.0 m [3.2 ft]
    • Cable PVC, 3,0 m [9.8 ft]
  • Media Compatibility
    • <p>The PX3 Series is compatible with common HFC (hydrofluorocarbon) refrigerants such as R410A and R134A, next generation low global warming potential (GWP) refrigerants such as R448A (Solstice® N40), R32 and R1234ZE, engine oil, petroleum-based hydraulic fluids, DOT 3 brake fluid, and dry air. For ammonia and other corrosive media, see Honeywell’s SPT Series.</p> <p>The PX3 Series is not recommended for use with media involving water, saturated air such as steam and vapor, and ammonia.</p>
  • Compensated Temperature Range
    • -40°C to 125°C [-40°F to 257°F]
  • Accuracy
    • ±0.25 %FSS
  • Temperature Compensation
    • Yes
  • Signal Conditioning
    • Amplified
  • Life
    • Greater than 10 million full scale pressure cycles over the calibrated pressure range
  • Supply Voltage
    • 8 Vdc to 30 Vdc (-40°C to 100°C)
    • 4.75 V to 5.25 V
  • Series Name
    • PX3
  • Agency Approvals and Standards
    • IP67
    • IP69K
  • Total Error Band
    • ±1.0 %FSS (-20°C to 85°C [-4°F to 185°F]), ±2.0 %FSS (<-20°C, >85°C [<-4°F, >185°F])
  • Storage Temperature
    • -40°C to 125°C [-40°F to 257°F]
  • Shock : 100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C)
  • Burst Pressure : 51 bar|103 bar|750 psi|80 bar|1500 psi|1150 psi
  • Operating Temperature : -40°C to 125°C [-40°F to 257°F]
  • Measurement Type : Sealed gage|Absolute
  • Vibration : 20 G sweep, 10 Hz to 2000 Hz (at 25°C)
  • Overpressure : 1000 psi|31 bar|69 bar|450 psi|32 bar
  • Pressure Range : 0 bar to 30 bar|0 bar to 25 bar|0 bar to 46 bar|0 bar to 40 bar|0 psi to 200 psi|0 psi to 100 psi|0 psi to 150 psi|0 bar to 8 bar|0 psi to 500 psi|0 bar to 16 bar|0 psi to 667 psi|0 bar to 20 bar|0 bar to 10 bar|0 psi to 300 psi|0 bar to 50 bar|0 psi to 250 psi|0 bar to 35 bar
  • Output Type : Ratiometric: 5.0 Vdc to 4.5 Vdc|Current: 4 mA to 20 mA
  • Response Time : <2 ms
  • Port Style : 1/8-27 NPT (ANSI/ASME B1.20.1)|1/4-18 NPT (ANSI/ASME B1.20.1)|7/16-20 UNF 1/4 in 45° Flare Female Schrader (SAE J512)|G 1/4 A-G (ISO 1179-3)
  • Electrical Connection : Cable PVC, 2,0 m [6.6 ft]|Cable, XLPE, 2.0 m [6.6 ft]|Metri-Pack 150, Standard (UL V-0)|Cable PVC, 1.0 m [3.2 ft]|Cable PVC, 3,0 m [9.8 ft]
  • Media Compatibility :

    The PX3 Series is compatible with common HFC (hydrofluorocarbon) refrigerants such as R410A and R134A, next generation low global warming potential (GWP) refrigerants such as R448A (Solstice® N40), R32 and R1234ZE, engine oil, petroleum-based hydraulic fluids, DOT 3 brake fluid, and dry air. For ammonia and other corrosive media, see Honeywell’s SPT Series.

    The PX3 Series is not recommended for use with media involving water, saturated air such as steam and vapor, and ammonia.

  • Compensated Temperature Range : -40°C to 125°C [-40°F to 257°F]
  • Accuracy : ±0.25 %FSS
  • Temperature Compensation : Yes
  • Signal Conditioning : Amplified
  • Life : Greater than 10 million full scale pressure cycles over the calibrated pressure range
  • Supply Voltage : 8 Vdc to 30 Vdc (-40°C to 100°C)|4.75 V to 5.25 V
  • Series Name : PX3
  • Agency Approvals and Standards : IP67|IP69K
  • Total Error Band : ±1.0 %FSS (-20°C to 85°C [-4°F to 185°F]), ±2.0 %FSS (<-20°C, >85°C [<-4°F, >185°F])
  • Storage Temperature : -40°C to 125°C [-40°F to 257°F]
Data Sheet
Name
Description
File Size
Date
Size
PX3 Series Heavy Duty Pressure Transducers
2.23 MB
12/3/2020
PDF 2.23 MB
Manuals and Guides
Name
Description
File Size
Date
Size
Airflow sensors contain advanced microstructure technology to provide a sensitive and fast response to flow, amount/direction of air or other gases. Potential applications include HVAC, gas metering, chromatography, vent hoods, and medical equipment.
4.14 MB
1/11/2021
PDF 4.14 MB
Installation Instructions
Name
Description
File Size
Date
Size
PX3 Series Heavy Duty Pressure Transducers
1.78 MB
12/3/2020
PDF 1.78 MB
CAD Model
Name
Description
File Size
Date
Size
PX3 Series CAD Models - grouped
2.45 MB
4/6/2021
2.45 MB
Brochure
Name
Description
File Size
Date
Size
Partners Providing Technical Safety and Productivity Solutions
10.07 MB
12/16/2020
PDF 10.07 MB
Oil and Gas Brochure
3.4 MB
12/3/2020
PDF 3.4 MB
Technical Note
Name
Description
File Size
Date
Size
Heavy Duty Pressure Transducers, PX3 Series, ROHS2 Certificate of Compliance
35.71 KB
12/3/2020
PDF 35.71 KB
Heavy Duty Pressure Transducers, PX3 Series, REACH Certificate of Compliance
38.42 KB
12/3/2020
PDF 38.42 KB
Total Error Band Specification for Honeywell Heavy Duty Pressure Transducers, PX2 Series and PX3 Series
285.01 KB
12/3/2020
PDF 285.01 KB
Application Note
Name
Description
File Size
Date
Size
Sensors and Switches in Front Loaders
2.54 MB
12/3/2020
PDF 2.54 MB
Sensors and Switches in Chemistry and Immunoassay Analyzers
1.24 MB
12/3/2020
PDF 1.24 MB
Heavy Duty Pressure Transducers, PX2 Series and PX3 Series
269.01 KB
12/3/2020
PDF 269.01 KB
Sensors and Switches for HVAC Applications
4.51 MB
1/11/2021
PDF 4.51 MB
Industrial Warehouse Solutions
2.85 MB
5/10/2021
PDF 2.85 MB
Product Photo
Name
Description
File Size
Date
Size
PX3 Series Product Photo
1.47 MB
4/21/2021
1.47 MB
Name
Description
File Size
Date
Size
Partners Providing Technical Safety and Productivity Solutions
10.07 MB
12/16/2020
PDF 10.07 MB
Sensors and Switches in Front Loaders
2.54 MB
12/3/2020
PDF 2.54 MB
Sensors and Switches in Chemistry and Immunoassay Analyzers
1.24 MB
12/3/2020
PDF 1.24 MB
Airflow sensors contain advanced microstructure technology to provide a sensitive and fast response to flow, amount/direction of air or other gases. Potential applications include HVAC, gas metering, chromatography, vent hoods, and medical equipment.
4.14 MB
1/11/2021
PDF 4.14 MB
Oil and Gas Brochure
3.4 MB
12/3/2020
PDF 3.4 MB
PX3 Series Heavy Duty Pressure Transducers
1.78 MB
12/3/2020
PDF 1.78 MB
Heavy Duty Pressure Transducers, PX3 Series, ROHS2 Certificate of Compliance
35.71 KB
12/3/2020
PDF 35.71 KB
Heavy Duty Pressure Transducers, PX3 Series, REACH Certificate of Compliance
38.42 KB
12/3/2020
PDF 38.42 KB
Total Error Band Specification for Honeywell Heavy Duty Pressure Transducers, PX2 Series and PX3 Series
285.01 KB
12/3/2020
PDF 285.01 KB
PX3 Series Heavy Duty Pressure Transducers
2.23 MB
12/3/2020
PDF 2.23 MB
Heavy Duty Pressure Transducers, PX2 Series and PX3 Series
269.01 KB
12/3/2020
PDF 269.01 KB
Sensors and Switches for HVAC Applications
4.51 MB
1/11/2021
PDF 4.51 MB
PX3 Series Product Photo
1.47 MB
4/21/2021
1.47 MB
PX3 Series CAD Models - grouped
2.45 MB
4/6/2021
2.45 MB
Industrial Warehouse Solutions
2.85 MB
5/10/2021
PDF 2.85 MB