https://sps.honeywell.com/us/en/search-results.html

Thermistors

126 Series

Matched large glass bead. -60 °C to 300 °C [-76 °F to 572 °F]

126 Series

Distributor Inventory

126 Series Thermistors are designed for use as precision sensing elements where curve-matched interchangeability is required for precise temperature control and precision temperature indication. These highly reliable products consist of a matched pair of hermetically sealed thermistors and may be selected to tolerances only limited to the system’s capability available to test them.

  • Dissipation constant in still air: 0,8 mW/°C
  • Time constant in air: 4.0 s
  • Nominal resistance at [25 °F to 77 °F]: 2,000 Ohm; 100,000 Ohm
  • Maximum diameter: 2,54 mm [0.10 in]
  • Termination material: platinum iridium
  • Lead length: 9,6 mm [0.375 in]

Others

  • Resistance
    • 100,000 Ohm
    • 2,000 Ohm
  • Operating Temperature
    • -60 °C to 300 °C [-76 °F to 572 °F]
  • Termination Material
    • Platinum iridium
  • Accuracy
    • 0 °C to 120 °C [32 °F to 248 °F]
    • 0 °C to 125 °C [32 °F to 257 °F]
  • Lead Length
    • 9,6 mm [0.375 in]
  • Tolerance
    • ±1,0 °C [1.8 °F]
    • ±0,5 °C [0.9 °F]
  • Time Constant in Air
    • 4.0 s
  • Series Name
    • 126
  • Dissipation Constant
    • 0,8 m/W°C
  • Diameter
    • 2,54 mm [0.10 in]
  • Beta
    • 3669
    • 3518

Others

  • Resistance
    • 100,000 Ohm
    • 2,000 Ohm
  • Operating Temperature
    • -60 °C to 300 °C [-76 °F to 572 °F]
  • Termination Material
    • Platinum iridium
  • Accuracy
    • 0 °C to 120 °C [32 °F to 248 °F]
    • 0 °C to 125 °C [32 °F to 257 °F]
  • Lead Length
    • 9,6 mm [0.375 in]
  • Tolerance
    • ±1,0 °C [1.8 °F]
    • ±0,5 °C [0.9 °F]
  • Time Constant in Air
    • 4.0 s
  • Series Name
    • 126
  • Dissipation Constant
    • 0,8 m/W°C
  • Diameter
    • 2,54 mm [0.10 in]
  • Beta
    • 3669
    • 3518
  • Resistance : 100,000 Ohm|2,000 Ohm
  • Operating Temperature : -60 °C to 300 °C [-76 °F to 572 °F]
  • Termination Material : Platinum iridium
  • Accuracy : 0 °C to 120 °C [32 °F to 248 °F]|0 °C to 125 °C [32 °F to 257 °F]
  • Lead Length : 9,6 mm [0.375 in]
  • Tolerance : ±1,0 °C [1.8 °F]|±0,5 °C [0.9 °F]
  • Time Constant in Air : 4.0 s
  • Series Name : 126
  • Dissipation Constant : 0,8 m/W°C
  • Diameter : 2,54 mm [0.10 in]
  • Beta : 3669|3518
Brochure
Name
Description
File Size
Date
Size
Thermal Sensors
11.07 MB
9/10/2020
PDF 11.07 MB
Name
Description
File Size
Date
Size
Thermal Sensors
11.07 MB
9/10/2020
PDF 11.07 MB