Oil & Gas Pressure Transducers
Model 437
Wing union pressure transducers. Wide aperture. 0 psi to 20,000 psi. ±0.2 % full-scale accuracy. Protective cage option
Honeywell Models 435/437 Wing Union/Hammer Union Pressure Sensors are rugged devices designed for use with Weco® 1502 fittings for both offshore and land-based oil and gas applications. Available in two accuracy levels (±0.1 %FSS BFSL or ±0.2 %FSS BFSL), Models 435/437 are typically used in demanding applications such as well stimulation and circulation systems. The higher accuracy option (available on Model 435 only) at ±0.1 % full scale provides more confidence in the actual measured pressure value, particularly for smaller changes in pressure, allowing drilling operation adjustments as needed.
Models 435/437 are constructed as an all-welded, stainless steel assembly with the sensor diaphragm and wing union fitting machined as one part. This helps provide hermetic integrity, which reduces the chance of media leakage vs. multi-piece parts, and increases reliability. The isolated pressure sensing diaphragm minimizes zero-shift during hammer up and eliminates long-term signal drift in the field. The Weco 1502 (50,8 mm [2 in]) Wing Union-compatible fittings are machined of Inconel® X-750, which provides additional durability with highly abrasive and corrosive media, while the Honeywell proprietary stainless steel electrical connection provides enhanced secondary pressure containment.
Value to Customers
- Durable: Weco® Wing Union-compatible fittings are machined of Inconel® X-750, or optional NACE-compliant Inconel® 718, allowing for use with abrasive and corrosive media. Protective cage option provides electrical connection protection.
- Reliable: All-welded, stainless steel assembly, shock/vibration ratings, and isolated pressure sensing diaphragm increase reliability.
- Accurate: High accuracy option provides confidence in the actual measured pressure value, particularly for smaller changes in pressure, allowing drilling operation adjustments as needed.
- Availability and service: Global manufacturing and support allow Honeywell to quickly provide customized products, helping customers meet project timelines.
Differentiators
- High or standard accuracy allow ability to obtain tighter system requirements and lower error bands than comparable competitive models
- Shunt calibration option enhances configurability and flexibility; 1-wire shunt calibration is achievable with a single barrier application, helping to minimize installation costs
- IEC Ex approval allows for use in hazardous areas, in Asia-Pacific and EMEA, and by the U.S. Coast Guard
- Protective cage option
- Welded construction
Others
- Overload (burst)
- 250 % rated pressure or limit of Weco® 1502 fitting
- Intrinsically Safe Option
- yes
- Pressure Range
- 15,000 psi
- 5,000 psi
- 10,000 psi
- 6,000 psi
- Internal Amplifiers
- 4 mA to 20 mA, two wire, intrinsically safe
- Pressure Unit
- Gage
- Temperature (Compensated)
- -40 °C to 85 °C [-40 °F to 185 °F]
- Pressure Port
- Weco® 1502 wing union, wide aperture, Ø22,35 mm [0.88 in]
- Product Dimensions
- Ø93,98 mm x 88,9 mm [Ø3.7 in x 3.5 in]
- Circuit Protection
- Reverse polarity protection of supply leads
- UNSPSC Commodity
- 41112110 Pressure Transducer
- Form Factor
- Oil & Gas
- Temperature Effect (Span)
- <±0.018 %reading/°C [0.01 %reading/°F]
- Accuracy
- ±0.2 %FSS
- Temperature Effect (Zero)
- <±0.018 %FSS/°C [0.01 %FSS/°F]
- Output
- 4 mA to 20 mA, two wire
- Overload (safe)
- 150 % rated FS or limit of Weco® 1502 fitting
- Agency Approvals and Standards
- CE, cFMus, EX, and IEC Ex approvals
- Insulation Resistance
- >100 MOhm @ 20 Vdc
- Frequency Response
- 2500 Hz
- Electrical Termination (std)
- MS series compatible 4-pin (32A-14S-2P-10-M2)
- Bendix PT 6-pin, PTIH-10-6P
- Case Material
- Inconel® X-750
- UNSPSC Code
- 41112110
- Temperature (Operating)
- -40 °C to 125 °C [-40 °F to 257 °F]
- Wetted Parts Material
- Inconel® X-750
- Media
- Corrosive and abrasive service, Inconel® X-750
- Calibration
- Two-wire shunt calibration
- 5-point calibration: 0 %, 50 %, and 100 % of full scale
- One-wire shunt calibration
- Sealing
- Hermetically sealed IP68/NEMA 6P
- Weight
- 2.2 kg [4.85 lb]
- RFI/EMI Protection
- Noise immunity up to 2.7 GHz
- Series Name
- 437
- Zero and Span Adjustments
- Field adjustable
- Resolution
- Infinite
Others
- Overload (burst)
- 250 % rated pressure or limit of Weco® 1502 fitting
- Intrinsically Safe Option
- yes
- Pressure Range
- 15,000 psi
- 5,000 psi
- 10,000 psi
- 6,000 psi
- Internal Amplifiers
- 4 mA to 20 mA, two wire, intrinsically safe
- Pressure Unit
- Gage
- Temperature (Compensated)
- -40 °C to 85 °C [-40 °F to 185 °F]
- Pressure Port
- Weco® 1502 wing union, wide aperture, Ø22,35 mm [0.88 in]
- Product Dimensions
- Ø93,98 mm x 88,9 mm [Ø3.7 in x 3.5 in]
- Circuit Protection
- Reverse polarity protection of supply leads
- UNSPSC Commodity
- 41112110 Pressure Transducer
- Form Factor
- Oil & Gas
- Temperature Effect (Span)
- <±0.018 %reading/°C [0.01 %reading/°F]
- Accuracy
- ±0.2 %FSS
- Temperature Effect (Zero)
- <±0.018 %FSS/°C [0.01 %FSS/°F]
- Output
- 4 mA to 20 mA, two wire
- Overload (safe)
- 150 % rated FS or limit of Weco® 1502 fitting
- Agency Approvals and Standards
- CE, cFMus, EX, and IEC Ex approvals
- Insulation Resistance
- >100 MOhm @ 20 Vdc
- Frequency Response
- 2500 Hz
- Electrical Termination (std)
- MS series compatible 4-pin (32A-14S-2P-10-M2)
- Bendix PT 6-pin, PTIH-10-6P
- Case Material
- Inconel® X-750
- UNSPSC Code
- 41112110
- Temperature (Operating)
- -40 °C to 125 °C [-40 °F to 257 °F]
- Wetted Parts Material
- Inconel® X-750
- Media
- Corrosive and abrasive service, Inconel® X-750
- Calibration
- Two-wire shunt calibration
- 5-point calibration: 0 %, 50 %, and 100 % of full scale
- One-wire shunt calibration
- Sealing
- Hermetically sealed IP68/NEMA 6P
- Weight
- 2.2 kg [4.85 lb]
- RFI/EMI Protection
- Noise immunity up to 2.7 GHz
- Series Name
- 437
- Zero and Span Adjustments
- Field adjustable
- Resolution
- Infinite
- Overload (burst) : 250 % rated pressure or limit of Weco® 1502 fitting
- Intrinsically Safe Option : yes
- Pressure Range : 15,000 psi|5,000 psi|10,000 psi|6,000 psi
- Internal Amplifiers : 4 mA to 20 mA, two wire, intrinsically safe
- Pressure Unit : Gage
- Temperature (Compensated) : -40 °C to 85 °C [-40 °F to 185 °F]
- Pressure Port : Weco® 1502 wing union, wide aperture, Ø22,35 mm [0.88 in]
- Product Dimensions : Ø93,98 mm x 88,9 mm [Ø3.7 in x 3.5 in]
- Circuit Protection : Reverse polarity protection of supply leads
- UNSPSC Commodity : 41112110 Pressure Transducer
- Form Factor : Oil & Gas
- Temperature Effect (Span) : <±0.018 %reading/°C [0.01 %reading/°F]
- Accuracy : ±0.2 %FSS
- Temperature Effect (Zero) : <±0.018 %FSS/°C [0.01 %FSS/°F]
- Output : 4 mA to 20 mA, two wire
- Overload (safe) : 150 % rated FS or limit of Weco® 1502 fitting
- Agency Approvals and Standards : CE, cFMus, EX, and IEC Ex approvals
- Insulation Resistance : >100 MOhm @ 20 Vdc
- Frequency Response : 2500 Hz
- Electrical Termination (std) : MS series compatible 4-pin (32A-14S-2P-10-M2)|Bendix PT 6-pin, PTIH-10-6P
- Case Material : Inconel® X-750
- UNSPSC Code : 41112110
- Temperature (Operating) : -40 °C to 125 °C [-40 °F to 257 °F]
- Wetted Parts Material : Inconel® X-750
- Media : Corrosive and abrasive service, Inconel® X-750
- Calibration : Two-wire shunt calibration|5-point calibration: 0 %, 50 %, and 100 % of full scale|One-wire shunt calibration
- Sealing : Hermetically sealed IP68/NEMA 6P
- Weight : 2.2 kg [4.85 lb]
- RFI/EMI Protection : Noise immunity up to 2.7 GHz
- Series Name : 437
- Zero and Span Adjustments : Field adjustable
- Resolution : Infinite