OOM (Envitec)

Oxygen sensors for medical use: compliant with European MDD (CE certification). Compliant to EU RoHS Directive 2011/65/EU. Meets ISO 80601-2-55. Designed & manufactured according to EN ISO 13485. Higher accuracy and reliability in response

Overview
OOM (Envitec) sensors

EnviteC Cross Reference List   |   Tech Support

From standard sensors to customized sensors: Experienced EnviteC engineers analyze customer requirements. This input is used for different standard and OEM applications, and ongoing support is provided right up to the final integration in the solution. EnviteC designs customized sensors characterized by a high degree of precision, for example with different signal levels or temperature compensation elements.

Step into the lead-free future: With innovative technology and engineering expertise, Honeywell has developed a patent-pending, lead-free oxygen sensor series. Honeywell lead-free O2 sensors are a one-to-one, drop-in replacement - no application redesign needed. This innovation was driven by European regulations to fulfill RoHS regulatory requirements for medical applications.

The EnviteC Medical Oxygen Sensors are intended as oxygen sensing component of an oxygen analyzer that measures oxygen concentration in breathing gas mixtures in the following applications: Sensing device for oxygen in medical ventilators, anesthesia machines, incubators, and control device of oxygen concentrators.

EnviteC by Honeywell

Data Sheet
Name
Description
File Size
Date
Size
Data Sheet - Medical Oxygen Sensor OOM202-2
application/pdf 466.35 KB
9/20/2024
466.35 KB
Data Sheet - Medical Oxygen Sensor OOM111
application/pdf 337.82 KB
9/20/2024
337.82 KB
Data Sheet - Medical Oxygen Sensor OOM104
application/pdf 354.14 KB
9/20/2024
354.14 KB
Data Sheet - Medical Oxygen Sensor OOM106
application/pdf 396.67 KB
9/20/2024
396.67 KB
Data Sheet - Medical Oxygen Sensor OOM103-1
application/pdf 389.73 KB
9/20/2024
389.73 KB
Data Sheet - Medical Oxygen Sensor OOM109
application/pdf 458.02 KB
9/20/2024
458.02 KB
Data Sheet - Medical Oxygen Sensor OOM102-1
application/pdf 388.61 KB
9/20/2024
388.61 KB
Data Sheet - Medical Oxygen Sensor OOM103
application/pdf 376.48 KB
9/20/2024
376.48 KB
Data Sheet - Medical Oxygen Sensor OOM202
application/pdf 431.42 KB
9/20/2024
431.42 KB
Data Sheet for OOM112 Medical Oxygen Sensor
application/pdf 356.3 KB
10/25/2024
356.3 KB
Data Sheet - Medical Oxygen Sensor OOM113
application/pdf 305.22 KB
10/25/2024
305.22 KB
Data Sheet - Medical Oxygen Sensor OOM103-1M
application/pdf 427.2 KB
9/20/2024
427.2 KB
Data Sheet - Medical Oxygen Sensor OOM202-2S
application/pdf 378.51 KB
9/20/2024
378.51 KB
Data Sheet - Medical Oxygen Sensor OOM110
application/pdf 373.9 KB
9/20/2024
373.9 KB
Data Sheet - Medical Oxygen Sensor OOM102
application/pdf 383.78 KB
9/20/2024
383.78 KB
Data Sheet - Medical Oxygen Sensor OOM201
application/pdf 360.19 KB
9/20/2024
360.19 KB
Data Sheet - Medical Oxygen Sensor OOM101
application/pdf 380.45 KB
9/20/2024
380.45 KB
Data Sheet - Medical Oxygen Sensor OOM109-LF2
application/pdf 389.92 KB
9/20/2024
389.92 KB
Data Sheet - Medical Oxygen Sensor OOM105
application/pdf 375.05 KB
9/20/2024
375.05 KB
Data Sheet - Medical Oxygen Sensor OOM204
application/pdf 401.19 KB
9/20/2024
401.19 KB
Data Sheet - Medical Oxygen Sensor OOM202-1
application/pdf 435.39 KB
9/20/2024
435.39 KB
Manuals and Guides
Name
Description
File Size
Date
Size
OOM109-X Medical Oxygen Sensor - Operating Manual
application/pdf 105.02 KB
8/16/2023
105.02 KB
OOMLF Series Medical Oxygen Sensor Lead-Free (LF) - Operating Manual
application/pdf 493.85 KB
2/6/2025
493.85 KB
Operating manual OOM Series Medical Oxygen Sensor (except OOM109-X)
application/pdf 88.92 KB
5/8/2024
88.92 KB
Certificate
Name
Description
File Size
Date
Size
Manufacturers Declaration according to EU MDR
application/pdf 215.73 KB
6/26/2024
215.73 KB
Confirmation Letter on validity of EC Certificate (MDD)
application/pdf 405.61 KB
6/26/2024
405.61 KB
Certificate According To ISO 13485 (English)
application/pdf 340.29 KB
6/26/2024
340.29 KB
Confirmation statement about company renaming
application/pdf 227.43 KB
6/26/2024
227.43 KB
Certificate MDSAP ISO 13485
application/pdf 420.2 KB
6/26/2024
420.2 KB
EC Certificate (MDD)
application/pdf 129.43 KB
6/26/2024
129.43 KB
Form certificate on hygiene status and desinfection of returned product/s
application/pdf 469.94 KB
9/22/2021
469.94 KB
Form certificate on hygiene status and desinfection of returned product/s
application/pdf 470.7 KB
9/22/2021
470.7 KB
Others
Name
Description
File Size
Date
Size
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
application/pdf 34.46 KB
3/10/2022
34.46 KB
Form details on potential safety relevant failures or events
application/pdf 495.94 KB
9/22/2021
495.94 KB
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
application/pdf 211.68 KB
11/24/2021
211.68 KB
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
application/pdf 205.2 KB
11/24/2021
205.2 KB
Form details on potential safety relevant failures or events
application/pdf 492.27 KB
9/22/2021
492.27 KB
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
application/pdf 35.04 KB
3/10/2022
35.04 KB
Name
Description
File Size
Date
Size
Manufacturers Declaration according to EU MDR
application/pdf 215.73 KB
6/26/2024
215.73 KB
Confirmation Letter on validity of EC Certificate (MDD)
application/pdf 405.61 KB
6/26/2024
405.61 KB
Certificate According To ISO 13485 (English)
application/pdf 340.29 KB
6/26/2024
340.29 KB
Confirmation statement about company renaming
application/pdf 227.43 KB
6/26/2024
227.43 KB
Certificate MDSAP ISO 13485
application/pdf 420.2 KB
6/26/2024
420.2 KB
EC Certificate (MDD)
application/pdf 129.43 KB
6/26/2024
129.43 KB
OOM109-X Medical Oxygen Sensor - Operating Manual
application/pdf 105.02 KB
8/16/2023
105.02 KB
OOMLF Series Medical Oxygen Sensor Lead-Free (LF) - Operating Manual
application/pdf 493.85 KB
2/6/2025
493.85 KB
Data Sheet - Medical Oxygen Sensor OOM202-2
application/pdf 466.35 KB
9/20/2024
466.35 KB
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
application/pdf 34.46 KB
3/10/2022
34.46 KB
Data Sheet - Medical Oxygen Sensor OOM111
application/pdf 337.82 KB
9/20/2024
337.82 KB
Data Sheet - Medical Oxygen Sensor OOM104
application/pdf 354.14 KB
9/20/2024
354.14 KB
Form details on potential safety relevant failures or events
application/pdf 495.94 KB
9/22/2021
495.94 KB
Data Sheet - Medical Oxygen Sensor OOM106
application/pdf 396.67 KB
9/20/2024
396.67 KB
Form certificate on hygiene status and desinfection of returned product/s
application/pdf 469.94 KB
9/22/2021
469.94 KB
Data Sheet - Medical Oxygen Sensor OOM103-1
application/pdf 389.73 KB
9/20/2024
389.73 KB
Data Sheet - Medical Oxygen Sensor OOM109
application/pdf 458.02 KB
9/20/2024
458.02 KB
Data Sheet - Medical Oxygen Sensor OOM102-1
application/pdf 388.61 KB
9/20/2024
388.61 KB
Data Sheet - Medical Oxygen Sensor OOM103
application/pdf 376.48 KB
9/20/2024
376.48 KB
Data Sheet - Medical Oxygen Sensor OOM202
application/pdf 431.42 KB
9/20/2024
431.42 KB
Operating manual OOM Series Medical Oxygen Sensor (except OOM109-X)
application/pdf 88.92 KB
5/8/2024
88.92 KB
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
application/pdf 211.68 KB
11/24/2021
211.68 KB
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
application/pdf 205.2 KB
11/24/2021
205.2 KB
Data Sheet for OOM112 Medical Oxygen Sensor
application/pdf 356.3 KB
10/25/2024
356.3 KB
Data Sheet - Medical Oxygen Sensor OOM113
application/pdf 305.22 KB
10/25/2024
305.22 KB
Data Sheet - Medical Oxygen Sensor OOM103-1M
application/pdf 427.2 KB
9/20/2024
427.2 KB
Data Sheet - Medical Oxygen Sensor OOM202-2S
application/pdf 378.51 KB
9/20/2024
378.51 KB
Data Sheet - Medical Oxygen Sensor OOM110
application/pdf 373.9 KB
9/20/2024
373.9 KB
Data Sheet - Medical Oxygen Sensor OOM102
application/pdf 383.78 KB
9/20/2024
383.78 KB
Data Sheet - Medical Oxygen Sensor OOM201
application/pdf 360.19 KB
9/20/2024
360.19 KB
Form details on potential safety relevant failures or events
application/pdf 492.27 KB
9/22/2021
492.27 KB
Data Sheet - Medical Oxygen Sensor OOM101
application/pdf 380.45 KB
9/20/2024
380.45 KB
EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
application/pdf 35.04 KB
3/10/2022
35.04 KB
Data Sheet - Medical Oxygen Sensor OOM109-LF2
application/pdf 389.92 KB
9/20/2024
389.92 KB
Data Sheet - Medical Oxygen Sensor OOM105
application/pdf 375.05 KB
9/20/2024
375.05 KB
Data Sheet - Medical Oxygen Sensor OOM204
application/pdf 401.19 KB
9/20/2024
401.19 KB
Data Sheet - Medical Oxygen Sensor OOM202-1
application/pdf 435.39 KB
9/20/2024
435.39 KB
Form certificate on hygiene status and desinfection of returned product/s
application/pdf 470.7 KB
9/22/2021
470.7 KB
Name
Date
Size
Showing 1 to 10 of 125 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
DE800.A.2
OXYGEN SENSOR
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
DE800.A.2
OXYGEN SENSOR
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
DE800.V.1.NF
OXYGEN SENSOR
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
DE800.V.1.NF
OXYGEN SENSOR
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
DE800.V.2
OXYGEN SENSOR
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
DE800.V.2
OXYGEN SENSOR
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0013
OOM101 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20 mV, load 300 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0013
OOM101 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20 mV, load 300 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0014
OOM201 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0014
OOM201 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0015
OOM103 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3-pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0015
OOM103 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3-pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0016
OOM103-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0016
OOM103-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0019
OOM102 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3 pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0019
OOM102 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3 pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0020
OOM102-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0020
OOM102-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0021
OOM202-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 13 mV ... 16 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
E01-00-0021
OOM202-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 13 mV ... 16 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
Feedback