Product Overview:
Discreet design and rugged ABS-Polycarbonate housing for the 301IRFS set the standard for “at the source” gas detection in a chiller room. Mount directly to the chiller pad or low on the wall in close proximity to achieve early notifications in the event of a refrigerant leak.
ASHRAE No 15-2001 Mechanical Standard and B-52 Code Compliance. The ASHRAE and B-52 security standards have been established to minimize risk and protect the safety of mechanical room personnel and the environment at large. Honeywell’s 301IRF, together with the 301EM mechanical room controller, provides a complete solution that meets and even exceeds these rigorous standards. The 301EM can be configured to offer automatic fan, horn and strobe activation in addition to manual fan activation when the 301IRF detects a refrigerant.
Additional Features and Benefits:
User Friendly:
- State-of-the-art infrared sensor technology
- LED indicator
- Low-profile and rugged construction for low mounting in chiller/mechanical room
- Cost-effective answer for installation in areas where refrigeration gas hazards may be present
- R11, R22, R123, R125, R134A, R404A, R407C, R410A, R448A, R449A, R507A, R513A, R514A, R4310, 1233ZD, 1234ZE.
- Infrared sensing technology responds promptly
- Low-profile design suited for mounting directly to chiller pad or low on nearby wall
- Low maintenance
- Power requirement operates on 12 VDC power only
- Dimensions 4” H x 11” W x 2.5” D (10.2 x 28 x 6.3 m)
- Weight 2.33 lbs (0.603 kg)
Options
- Brand
- Honeywell
- Sub-Category
- Gas Detection Sensors & Transmitters
- Accuracy
- ± 40 ppm @ 500 ppm Percentage
- Visual Indicators
- Failure Indication: LED will Remain ON
- Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20
- Measuring Principle
- 3-Electrode Electrochemical
Dimensions & Weight
- Weight range
- 600 gram
Configuration
- Sensor Range
- 0 to 1,000 ppm
- Humidity Range
- 0 to 95% RH (Non-Condensing)
- Minimum Temperature
- 0°C
- Sensing Method
- Infrared Sensor
Applicability
- For Use With
- Used with the 301EM-20
Electricals
- Maximum Analog Input Supply Voltage
- 12 voltage direct current
- Maximum Analog Input Supply Current
- 2 A milliampere
Options
- Brand
- Honeywell
- Sub-Category
- Gas Detection Sensors & Transmitters
- Accuracy
- ± 40 ppm @ 500 ppm Percentage
- Visual Indicators
- Failure Indication: LED will Remain ON
- Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20
- Measuring Principle
- 3-Electrode Electrochemical
Dimensions & Weight
- Weight range
- 600 gram
Configuration
- Sensor Range
- 0 to 1,000 ppm
- Humidity Range
- 0 to 95% RH (Non-Condensing)
- Minimum Temperature
- 0°C
- Sensing Method
- Infrared Sensor
Applicability
- For Use With
- Used with the 301EM-20
Electricals
- Maximum Analog Input Supply Voltage
- 12 voltage direct current
- Maximum Analog Input Supply Current
- 2 A milliampere
- Brand : Honeywell|
- Sub-Category : Gas Detection Sensors & Transmitters|
- Weight range : 600 gram|
- Sensor Range : 0 to 1,000 ppm|
- Humidity Range : 0 to 95% RH (Non-Condensing)|
- Minimum Temperature : 0°C|
- For Use With : Used with the 301EM-20|
- Sensing Method : Infrared Sensor|
- Maximum Analog Input Supply Voltage : 12 voltage direct current|
- Maximum Analog Input Supply Current : 2 A milliampere|
- Accuracy : ± 40 ppm @ 500 ppm Percentage|
- Visual Indicators : Failure Indication: LED will Remain ON|Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20|
- Measuring Principle : 3-Electrode Electrochemical|