Fixed Gas Detectors
301IRF Refrigerant Gas Detector
301IRF Refrigerant Gas Detector
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Product Overview:
Discreet design and rugged ABS-Polycarbonate housing for the 301IRFS set the standard for “at the source” gas detection in a chiller room. Mount directly to the chiller pad or low on the wall in close proximity to achieve early notifications in the event of a refrigerant leak.
ASHRAE No 15-2001 Mechanical Standard and B-52 Code Compliance. The ASHRAE and B-52 security standards have been established to minimize risk and protect the safety of mechanical room personnel and the environment at large. Honeywell’s 301IRF, together with the 301EM mechanical room controller, provides a complete solution that meets and even exceeds these rigorous standards. The 301EM can be configured to offer automatic fan, horn and strobe activation in addition to manual fan activation when the 301IRF detects a refrigerant.
Additional Features and Benefits:
User Friendly:
- State-of-the-art infrared sensor technology
- LED indicator
- Low-profile and rugged construction for low mounting in chiller/mechanical room
- Cost-effective answer for installation in areas where refrigeration gas hazards may be present
- R11, R22, R123, R125, R134A, R404A, R407C, R410A, R448A, R449A, R507A, R513A, R514A, R4310, 1233ZD, 1234ZE.
- Infrared sensing technology responds promptly
- Low-profile design suited for mounting directly to chiller pad or low on nearby wall
- Low maintenance
- Power requirement operates on 12 VDC power only
- Dimensions 4” H x 11” W x 2.5” D (10.2 x 28 x 6.3 m)
- Weight 2.33 lbs (0.603 kg)
Overview
- Brand
- Honeywell
Features
- Sub-Category
- Gas Detection Sensors & Transmitters
- Visual Indicators
- Failure Indication: LED will Remain ON
- Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20
- Measuring Principle
- 3-Electrode Electrochemical
Dimensions & Weight
- Weight range
- 600 g
Technical Specifications
- Sensor Range
- 0 to 1,000 ppm
- Humidity Range
- 0 to 95% RH (Non-Condensing)
- Sensing Method
- Infrared Sensor
- Accuracy
- ± 40 ppm @ 500 ppm
Operating Characteristics
- Minimum Temperature
- 0°C
Applications & Compatibility
- For Use With
- Used with the 301EM-20
Electrical Specifications
- Maximum Analog Input Supply Voltage
- 12
- Maximum Analog Input Supply Current
- 2 A
Overview
- Brand
- Honeywell
Features
- Sub-Category
- Gas Detection Sensors & Transmitters
- Visual Indicators
- Failure Indication: LED will Remain ON
- Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20
- Measuring Principle
- 3-Electrode Electrochemical
Dimensions & Weight
- Weight range
- 600 g
Technical Specifications
- Sensor Range
- 0 to 1,000 ppm
- Humidity Range
- 0 to 95% RH (Non-Condensing)
- Sensing Method
- Infrared Sensor
- Accuracy
- ± 40 ppm @ 500 ppm
Operating Characteristics
- Minimum Temperature
- 0°C
Applications & Compatibility
- For Use With
- Used with the 301EM-20
Electrical Specifications
- Maximum Analog Input Supply Voltage
- 12
- Maximum Analog Input Supply Current
- 2 A
- Brand : Honeywell
- Sub-Category : Gas Detection Sensors & Transmitters
- Weight range : 600 g
- Sensor Range : 0 to 1,000 ppm
- Humidity Range : 0 to 95% RH (Non-Condensing)
- Minimum Temperature : 0°C
- For Use With : Used with the 301EM-20
- Sensing Method : Infrared Sensor
- Maximum Analog Input Supply Voltage : 12
- Maximum Analog Input Supply Current : 2 A
- Accuracy : ± 40 ppm @ 500 ppm
- Visual Indicators : Failure Indication: LED will Remain ON|Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20
- Measuring Principle : 3-Electrode Electrochemical
Manuals and Guides
Brochure
Technical Note
Please sign in to view part numbers available for purchase based on your account Sign In
Please sign in to view part numbers available for purchase based on your account Sign In