/content/sps/au/en/search-results.html

Portables

AreaRAE Plus

Transportable area monitor for multiple threat detection

Overview
The AreaRAE Plus provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to configure device. Plus, you’ll have vital details about threats happening in real-time—arming you with the information you need to act quickly.Features and Benefits:
  • Monitors up to seven threats, including VOCs, combustibles, Toxics and Oxygen
  • Optional meteorological sensor for tracking toxic plumes
  • 7R+ photoionization detector (PID) for monitoring VOCs at parts per million
  • Secondary radio module (Mesh) act as an communication Hub for other wireless devices
  • Ruggedized, portable, and weather-resistant design for harsh environments
  • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations
Application:
  • Confined Space Entry
  • Environmental Cleanups/ Remediation
  • Fence Line Monitoring
  • Leak Detection
  • Plant Shutdown & Turn-Around
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • RAE

Category

  • Sub-Category
    • Transportable

Dimension & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Range

  • Humidity Range
    • 0%-95% percent
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)

Alarm

  • Alarm Type
    • Visual, Audible, Vibrating

Battery & Charging

  • Battery Run Time
    • 20 Hours hours

Certifications

  • Standards
    • US / Canada: Class 1, Division 2 Groups A, B, C, D

Datalogging

  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

Features & Benefits

  • Benefits
    • Delivers real-time readings to Honeywell’s

Options

  • User Options
    • 3 operation and programming keys

Warranty

  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Wireless

  • Wireless Technology
    • BLE, MESH, WiFi, LORA

Additional Specifications

  • Ingress Protection
    • IP65
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3

Brand

  • Brand
    • RAE

Category

  • Sub-Category
    • Transportable

Dimension & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Range

  • Humidity Range
    • 0%-95% percent
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)

Alarm

  • Alarm Type
    • Visual, Audible, Vibrating

Battery & Charging

  • Battery Run Time
    • 20 Hours hours

Certifications

  • Standards
    • US / Canada: Class 1, Division 2 Groups A, B, C, D

Datalogging

  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

Features & Benefits

  • Benefits
    • Delivers real-time readings to Honeywell’s

Options

  • User Options
    • 3 operation and programming keys

Warranty

  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Wireless

  • Wireless Technology
    • BLE, MESH, WiFi, LORA

Additional Specifications

  • Ingress Protection
    • IP65
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
  • Brand : RAE
  • Sub-Category : Transportable
  • Instrument Size : 12.36” x 12.04” x 6.53”
  • Humidity Range : 0%-95% percent
  • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Alarm Type : Visual, Audible, Vibrating
  • Battery Run Time : 20 Hours hours
  • Standards : US / Canada: Class 1, Division 2 Groups A, B, C, D
  • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Benefits : Delivers real-time readings to Honeywell’s
  • User Options : 3 operation and programming keys
  • Warranty : Four years for O2 Liquid Oxygen sensors
  • Wireless Technology : BLE, MESH, WiFi, LORA
  • Ingress Protection : IP65
  • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
Data Sheet
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
application/pdf 570.6 KB
10/5/2023
570.6 KB
Manuals and Guides
Name
Description
File Size
Date
Size
AreaRAE Plus & AreaRAE Pro - User Guide - English
application/pdf 18.86 MB
4/12/2023
18.86 MB
AreaRAE Pro and Plus - Quick start guide
application/pdf 689.87 KB
10/7/2021
689.87 KB
AreaRAE Plus & AreaRAE Pro User's Guide
application/pdf 5.65 MB
10/5/2023
5.65 MB
Firmware
Name
Description
File Size
Date
Size
Area RAE 1.12 Firmware and Release Notes
application/zip 2.01 MB
8/18/2023
2.01 MB
AREARAE Plus / Pro v 1.08
application/zip 1.57 MB
10/11/2021
1.57 MB
Brochure
Name
Description
File Size
Date
Size
AreaRAE Plus Brochure
application/pdf 3.23 MB
10/5/2023
3.23 MB
Technical Note
Name
Description
File Size
Date
Size
application/pdf 146.2 KB
8/10/2022
146.2 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
10/5/2023
1.09 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 840.24 KB
10/5/2023
840.24 KB
AreaRAE PlusPro Technical Note 106A
application/pdf 428.85 KB
10/5/2023
428.85 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
10/5/2023
1.45 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
application/pdf 126.69 KB
10/5/2023
126.69 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 610.55 KB
10/5/2023
610.55 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 995.19 KB
10/5/2023
995.19 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 788.59 KB
10/5/2023
788.59 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 885.67 KB
10/5/2023
885.67 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 931.71 KB
10/5/2023
931.71 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.89 KB
10/5/2023
785.89 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 796.74 KB
10/5/2023
796.74 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 951.67 KB
10/5/2023
951.67 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 912.47 KB
10/5/2023
912.47 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
application/pdf 1.02 MB
10/5/2023
1.02 MB
Technical Note 144 Handling LEL Sensor Poisons
application/pdf 803.19 KB
10/5/2023
803.19 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
8/3/2022
820.7 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 945.44 KB
10/5/2023
945.44 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 885.87 KB
10/5/2023
885.87 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 815.63 KB
10/5/2023
815.63 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
10/5/2023
1.08 MB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
10/5/2023
1.01 MB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 790.02 KB
10/5/2023
790.02 KB
White Paper
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 950.38 KB
10/5/2023
950.38 KB
Certificate
Name
Description
File Size
Date
Size
RM2400A EU Component of Conformity to Certificates
application/pdf 111.24 KB
7/12/2022
111.24 KB
AreaRAE Plus and Pro - Certificate of compliance
application/pdf 45.13 KB
10/7/2021
45.13 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 228 - Facility and Venue Protection
application/pdf 1.1 MB
10/5/2023
1.1 MB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
10/5/2023
1.26 MB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 965.94 KB
10/5/2023
965.94 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 751.37 KB
10/5/2023
751.37 KB
Application Note 215: Gas Detection In The Marine Industries
application/pdf 890.46 KB
10/5/2023
890.46 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.08 MB
10/5/2023
1.08 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 827.32 KB
10/5/2023
827.32 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 832.5 KB
10/5/2023
832.5 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
10/5/2023
1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 656.89 KB
10/5/2023
656.89 KB
Name
Description
File Size
Date
Size
Application Note 228 - Facility and Venue Protection
1.1 MB
10/5/2023
1.1 MB
Area RAE 1.12 Firmware and Release Notes
2.01 MB
8/18/2023
2.01 MB
AreaRAE Plus & AreaRAE Pro - User Guide - English
18.86 MB
4/12/2023
18.86 MB
RM2400A EU Component of Conformity to Certificates
111.24 KB
7/12/2022
111.24 KB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
10/5/2023
1.26 MB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
965.94 KB
10/5/2023
965.94 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
10/5/2023
1.09 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
840.24 KB
10/5/2023
840.24 KB
AreaRAE PlusPro Technical Note 106A
428.85 KB
10/5/2023
428.85 KB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
950.38 KB
10/5/2023
950.38 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
751.37 KB
10/5/2023
751.37 KB
A Guideline for Pid Instrument Response
1.45 MB
10/5/2023
1.45 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
126.69 KB
10/5/2023
126.69 KB
Application Note 215: Gas Detection In The Marine Industries
890.46 KB
10/5/2023
890.46 KB
AreaRAE Pro and Plus - Quick start guide
689.87 KB
10/7/2021
689.87 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
610.55 KB
10/5/2023
610.55 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
995.19 KB
10/5/2023
995.19 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.08 MB
10/5/2023
1.08 MB
Technical Note 146 Turning On UV Lamps In A PID Monitor
788.59 KB
10/5/2023
788.59 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
827.32 KB
10/5/2023
827.32 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
885.67 KB
10/5/2023
885.67 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
931.71 KB
10/5/2023
931.71 KB
AreaRAE Plus Datasheet
570.6 KB
10/5/2023
570.6 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.89 KB
10/5/2023
785.89 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
796.74 KB
10/5/2023
796.74 KB
AreaRAE Plus Brochure
3.23 MB
10/5/2023
3.23 MB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
951.67 KB
10/5/2023
951.67 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
912.47 KB
10/5/2023
912.47 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
1.02 MB
10/5/2023
1.02 MB
Technical Note 144 Handling LEL Sensor Poisons
803.19 KB
10/5/2023
803.19 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
832.5 KB
10/5/2023
832.5 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
10/5/2023
1.1 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
8/3/2022
820.7 KB
AREARAE Plus / Pro v 1.08
1.57 MB
10/11/2021
1.57 MB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
945.44 KB
10/5/2023
945.44 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
885.87 KB
10/5/2023
885.87 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
815.63 KB
10/5/2023
815.63 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
10/5/2023
1.08 MB
Technical Note 182 Basics of Wireless Security
1.01 MB
10/5/2023
1.01 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
656.89 KB
10/5/2023
656.89 KB
AreaRAE Plus & AreaRAE Pro User's Guide
5.65 MB
10/5/2023
5.65 MB
AreaRAE Plus and Pro - Certificate of compliance
45.13 KB
10/7/2021
45.13 KB
Technical Note 130 Setting Alarm Limits For Mixtures
790.02 KB
10/5/2023
790.02 KB
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
570.6 KB
10/5/2023
AreaRAE Plus & AreaRAE Pro - User Guide - English
18.86 MB
4/12/2023
AreaRAE Pro and Plus - Quick start guide
689.87 KB
10/7/2021
AreaRAE Plus & AreaRAE Pro User's Guide
5.65 MB
10/5/2023
Area RAE 1.12 Firmware and Release Notes
2.01 MB
8/18/2023
AREARAE Plus / Pro v 1.08
1.57 MB
10/11/2021
AreaRAE Plus Brochure
3.23 MB
10/5/2023
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
10/5/2023
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
840.24 KB
10/5/2023
AreaRAE PlusPro Technical Note 106A
428.85 KB
10/5/2023
A Guideline for Pid Instrument Response
1.45 MB
10/5/2023
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
126.69 KB
10/5/2023
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
610.55 KB
10/5/2023
Technical Note 169 Theory And Operation Of NDIR Sensors
995.19 KB
10/5/2023
Technical Note 146 Turning On UV Lamps In A PID Monitor
788.59 KB
10/5/2023
Technical Note 159 Chemical Warfare Agent Measurements By PID
885.67 KB
10/5/2023
Technical Note 165 Combating Drift In Portable And Fixed PIDs
931.71 KB
10/5/2023
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.89 KB
10/5/2023
Technical Note 114 Sensor Specifications and Cross-Sensitivities
796.74 KB
10/5/2023
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
951.67 KB
10/5/2023
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
912.47 KB
10/5/2023
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
1.02 MB
10/5/2023
Technical Note 144 Handling LEL Sensor Poisons
803.19 KB
10/5/2023
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
8/3/2022
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
945.44 KB
10/5/2023
Technical Note 161 Intrinsic Safety And Hazardous Locations
885.87 KB
10/5/2023
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
815.63 KB
10/5/2023
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
10/5/2023
Technical Note 182 Basics of Wireless Security
1.01 MB
10/5/2023
Technical Note 130 Setting Alarm Limits For Mixtures
790.02 KB
10/5/2023
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
950.38 KB
10/5/2023
RM2400A EU Component of Conformity to Certificates
111.24 KB
7/12/2022
AreaRAE Plus and Pro - Certificate of compliance
45.13 KB
10/7/2021
Application Note 228 - Facility and Venue Protection
1.1 MB
10/5/2023
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
10/5/2023
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
965.94 KB
10/5/2023
Measurement Of PGMEA Using Photoionization Detectors_12-11
751.37 KB
10/5/2023
Application Note 215: Gas Detection In The Marine Industries
890.46 KB
10/5/2023
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.08 MB
10/5/2023
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
827.32 KB
10/5/2023
Application Note 205 - Measuring Heat Transfer Fluids With A PID
832.5 KB
10/5/2023
Application Note 000: RAE Systems PID Overview
1.1 MB
10/5/2023
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
656.89 KB
10/5/2023