Sophisticated software algorithms and dual microprocessors ensure that the FS24X has the highest fire detection performance combined with optimal false alarm rejection. • Quick Specs • Sensitivity: Very high, high, medium and low -switch selectable
.
TheFS24X is the latest generation high technology Multi-Spectrum Triple IR (IR/IR/IR/Visible) Flame Detector, which is part of our FSX family of advanced technology Electro-Optical fire detectors. Using our patented* WideBand IR™, WideBand 4.3 micron IR™, and Visible detection technology, theFS24X is a quantum leap in flame detection. Sophisticated software algorithms and dual microprocessors ensure that theFS24X has the highest fire detection performance combined with optimal false alarm rejection.The WideBand IR™ Infrared technology using high-speed solid-state Quantum sensors allows detection of all types of fires, hydrocarbon and non-hydrocarbon, in all weather conditions. If the detector’s signal is blocked by ordinary window glass, the patented WideBand IR sensors will still alarm to the fire but at a reduced sensitivity and slower response time..
Dual microprocessors provide a high level of fail-safe operation combined with fast and reliable performance. The Master Microprocessor performs high-speed digital sampling and signal-processing calculations: while the slave microprocessor handles various sensor data, performs communications, self-diagnostics and provides interface versatility: and additional memory for storing Event Log and FirePic™ data..
TheFSX family of detectors feature our patented* FirePic data storage and information retrieval facility. FirePic™ records pre-fire data, which can be recovered from the Detector’s non-volatile flash memory for post fire analysis and postulation of the fire cause. Additionally, unique Real-Time Graphing (RTG™) allows viewing of the data that the Detector actually sees. A combination of outputs makes theFS24X a truly versatile detector for today’s demanding industrial requirements.
TheFS24X Flame Detector has a detection range greater than 200 feet (Very High Sensitivity setting) for the detection of a one square-foot Heptane reference fire and has a cone of vision far greater in volumetric coverage than any other Multi-Spectrum IR Detector. This means fewer detectors can be used as compared to other manufacturers’ detectors..
Additional Features and Benefits:.
Features.
- Patented* WideBand IR™ Technology
- Patented* Electronic Frequency Analysis™
- Visible Sensor for optimum false alarm rejection
- Selectable detection sensitivities
- Field-of-View: 110° full 100% cone-of-vision (90° full 100% cone-of-vision model also available)
- Dual microprocessors for reliable performance
- Real-time clock for accurate time dating of events
- FirePic™ — pre-fire event data storage
- Event log with date and time stamp
- RS-485 ModBus communication
- Non-Isolated 4-20 mA Analog output (sink or source)
- Alarm, Fault and Fire Verification relays
- Automatic optical path and electronic self-test
- Widest operating temperature range
- Patented* Electronics Module for components protection with easy plug-in terminations and field installation
- Two ¾” NPT OR 25mm conduit entries
- Low power consumption
- High RFI and EMI immunity
- FM, ATEX, CE mark approvals
- Meets SIL 2 requirements .
- Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
- User selectable outputs
- Optimal false alarm rejection for all environmental conditions
- Minimal maintenance for trouble-free operation
- PC software and Interface Module (FSIM) for fault diagnostics, real-time graphics (RTGs), and downloading of FirePics™ and event log
- Suitable for a wide variety of applications
- Easy electronics module replacement
- Test lamps for manual testing.
Others
- Features
- Optimal false alarm rejection
- Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
- User selection outputs
Others
- Features
- Optimal false alarm rejection
- Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
- User selection outputs
- Features : Optimal false alarm rejection|Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions|User selection outputs
Data Sheet
Name
Description
File Size
Date
Size
FS24X Flame Detector - Performance Addendum
application/pdf 2.06 MB
5/24/2022
2.06 MB
Manuals and Guides
Name
Description
File Size
Date
Size
FSL100 Flame Detectors,FS10-R,FS24X Flame Detector,SS2 Flame Detector,FS20X Flame Detector,SS4 Flame Detector Product Guide
application/pdf 2.58 MB
5/5/2021
2.58 MB
FS24X Flame Detector - User Manual
application/pdf 1.74 MB
8/2/2022
1.74 MB
Firmware
Name
Description
File Size
Date
Size
FSX Flame Detector - DTM Toolkit
application/zip 49.28 MB
5/24/2022
49.28 MB
FS24X Flame Detector - A014R Tokenized DD R01
application/zip 183.01 KB
7/5/2022
183.01 KB
Brochure
Name
Description
File Size
Date
Size
FS24X Flame Detector - Brochure
application/pdf 284.79 KB
8/2/2022
284.79 KB
Technical Note
Name
Description
File Size
Date
Size
FS24X Flame Detector,FS20X Flame Detector Supplementing Flame Detection in Gas Detection Applications
application/pdf 200 KB
5/5/2021
200 KB
FS24X Flame Detector,FS20X Flame Detector Inverse Square Law - Flame
application/pdf 498.12 KB
5/5/2021
498.12 KB
FS24X Flame Detector,FS20X Flame Detector Fire Alarm versus Fire Verification
application/pdf 269.68 KB
5/5/2021
269.68 KB
FS24X Flame Detector,FS20X Flame Detector Test Lamps use in Flame Detection Applications
application/pdf 201.27 KB
5/5/2021
201.27 KB
FS24X Flame Detector,FS20X Flame Detector Automatic Self-Test for Optical Flame Detectors
application/pdf 203.45 KB
5/5/2021
203.45 KB
FS20X, FS24X Modbus Interface Technical Note
application/pdf 228.89 KB
5/5/2021
228.89 KB
Certificate
Name
Description
File Size
Date
Size
TL-1055 Test Lamp EU Declaration of Conformity
application/pdf 248.15 KB
5/5/2021
248.15 KB
FS24X Flame Detector,FS20X Flame Detector,SS2 Flame Detector,SS4 Flame Detector Atex Certificate
application/pdf 170 KB
5/5/2021
170 KB
TL-1055 Test Lamp ATEX CE EU Declaration of Conformity
application/pdf 256.61 KB
5/5/2021
256.61 KB
FS24X and FS24X-9 Atex Declaration of Conformity
application/pdf 464.37 KB
5/5/2021
464.37 KB
FS24X Flame Detector,FS20X Flame Detector,SS2 Flame Detector,SS4 Flame Detector IECEx Certificate of Conformity
application/pdf 949.8 KB
5/5/2021
949.8 KB
FSX SS4 Certificate of Conformity
application/pdf 474.98 KB
5/5/2021
474.98 KB
Others
Name
Description
File Size
Date
Size
Recommendation for reducing Flame Detector False and Nuisance Alarms
application/pdf 223.8 KB
5/5/2021
223.8 KB
Name
Description
File Size
Date
Size
FS24X Flame Detector,FS20X Flame Detector Supplementing Flame Detection in Gas Detection Applications
200 KB
5/5/2021
200 KB
TL-1055 Test Lamp EU Declaration of Conformity
248.15 KB
5/5/2021
248.15 KB
FS24X Flame Detector,FS20X Flame Detector Inverse Square Law - Flame
498.12 KB
5/5/2021
498.12 KB
Recommendation for reducing Flame Detector False and Nuisance Alarms
223.8 KB
5/5/2021
223.8 KB
FS24X Flame Detector,FS20X Flame Detector,SS2 Flame Detector,SS4 Flame Detector Atex Certificate
170 KB
5/5/2021
170 KB
TL-1055 Test Lamp ATEX CE EU Declaration of Conformity
256.61 KB
5/5/2021
256.61 KB
FS24X and FS24X-9 Atex Declaration of Conformity
464.37 KB
5/5/2021
464.37 KB
FS24X Flame Detector,FS20X Flame Detector Fire Alarm versus Fire Verification
269.68 KB
5/5/2021
269.68 KB
FS24X Flame Detector,FS20X Flame Detector Test Lamps use in Flame Detection Applications
201.27 KB
5/5/2021
201.27 KB
FS24X Flame Detector,FS20X Flame Detector Automatic Self-Test for Optical Flame Detectors
203.45 KB
5/5/2021
203.45 KB
FS24X Flame Detector,FS20X Flame Detector,SS2 Flame Detector,SS4 Flame Detector IECEx Certificate of Conformity
949.8 KB
5/5/2021
949.8 KB
FS20X, FS24X Modbus Interface Technical Note
228.89 KB
5/5/2021
228.89 KB
FSL100 Flame Detectors,FS10-R,FS24X Flame Detector,SS2 Flame Detector,FS20X Flame Detector,SS4 Flame Detector Product Guide
2.58 MB
5/5/2021
2.58 MB
FS24X Flame Detector - Performance Addendum
2.06 MB
5/24/2022
2.06 MB
FS24X Flame Detector - A014R Tokenized DD R01
183.01 KB
7/5/2022
183.01 KB
Name
Description
File Size
Date
Size
FS24X Flame Detector - Performance Addendum
2.06 MB
5/24/2022
FSL100 Flame Detectors,FS10-R,FS24X Flame Detector,SS2 Flame Detector,FS20X Flame Detector,SS4 Flame Detector Product Guide
2.58 MB
5/5/2021
FS24X Flame Detector - A014R Tokenized DD R01
183.01 KB
7/5/2022
FS24X Flame Detector,FS20X Flame Detector Supplementing Flame Detection in Gas Detection Applications
200 KB
5/5/2021
FS24X Flame Detector,FS20X Flame Detector Inverse Square Law - Flame
498.12 KB
5/5/2021
FS24X Flame Detector,FS20X Flame Detector Fire Alarm versus Fire Verification
269.68 KB
5/5/2021
FS24X Flame Detector,FS20X Flame Detector Test Lamps use in Flame Detection Applications
201.27 KB
5/5/2021
FS24X Flame Detector,FS20X Flame Detector Automatic Self-Test for Optical Flame Detectors
203.45 KB
5/5/2021
FS20X, FS24X Modbus Interface Technical Note
228.89 KB
5/5/2021
TL-1055 Test Lamp EU Declaration of Conformity
248.15 KB
5/5/2021
FS24X Flame Detector,FS20X Flame Detector,SS2 Flame Detector,SS4 Flame Detector Atex Certificate
170 KB
5/5/2021
TL-1055 Test Lamp ATEX CE EU Declaration of Conformity
256.61 KB
5/5/2021
FS24X and FS24X-9 Atex Declaration of Conformity
464.37 KB
5/5/2021
FS24X Flame Detector,FS20X Flame Detector,SS2 Flame Detector,SS4 Flame Detector IECEx Certificate of Conformity
949.8 KB
5/5/2021
Recommendation for reducing Flame Detector False and Nuisance Alarms
223.8 KB
5/5/2021
Image
SKU
Description
FS24X-212-24-4
FS24X-212-23-4
FS24X-211-23-4
FS24X-912-24-8
FS24X-911-24-1 QuadBand™ IR3+ Detector, 316 Stainless Steel Encl. (2) M25 entries , CU-TR approval, T5 ( Op. Temp -60° to 75°C ) with FSX-A014R Optional Registered HART Module for FS24X Detectors Factory installed.
FS24X-912-24-1
FS24X-911-24-1 QuadBand™ IR3+ Detector, 316 Stainless Steel Encl. (2) M25 entries FM, cFM, IECEx & ATEX approved with FSX-A014R Optional Registered HART Module for FS24X Detectors Factory installed.
FS24X-912-23-8
FS24X-911-23-1 QuadBand™ IR3+ Detector, Copper-Free Aluminium Encl., (2) M25 entries , CU-TR approval, T5 ( Op. Temp -60° to 75°C ) with FSX-A014R Optional Registered HART Module for FS24X Detectors Factory installed.
FS24X-912-23-5
FS24X-911-23-1 QuadBand™ IR3+ Detector, Copper-Free Aluminium Encl., (2) M25 entries FM, dash 5, cFM, dash 5, IECEx & ATEX approved with FSX-A014R Optional Registered HART Module for FS24X Detectors Factory installed.
FS24X-912-23-1
FS24X-911-23-1 QuadBand™ IR3+ Detector, Copper-Free Aluminium Encl., (2) M25 entries FM, cFM, IECEx & ATEX approved with FSX-A014R Optional Registered HART Module for FS24X Detectors Factory installed.
FS24X-912-10
Electronics Module with Registered HART Communication for 911 and 211 series.
FS24X-911-24-8
QuadBand™ IR3+ Detector, 316 Stainless Steel Encl. (2) M25 entries , CU-TR approval, T5 ( Op. Temp -60° to 75°C )