UL. CSA. ATEX (CE). IEC Ex. INMETRO. NEMA 1. Div 1 & 2: Class I: B, C, D. Div 1 & 2: Class II: E, F, G

Distributor Inventory

MICRO SWITCH EX Series switches feature the smallest UL-listed housings available for use in hazardous locations. The EX Series switch cavity is designed to cool expanding gases below the ignition temperature of the surrounding explosive atmosphere.

The EX Series is capable of switching up to 20 A while providing ample wiring space for ease of installation. Single and double conduit openings are available. Dual conduit openings may allow for through wiring of multiple switches. The EX Series can be mounted from any of the switch's four sides.

Others

  • Operating Temperature
    • -40°C to 71°C [-40°F to 160°F]
    • -40°C to 204°C [-40°F to 400°F]
  • Sealed
    • Explosion-proof
  • Pretravel (PT)
    • 5,56 mm [0.219 in] (8°) max.
    • 1,27 mm [0.050 in] max.
  • Housing Material
    • Aluminum
  • Approvals
    • Div 1 & 2, Class I, Groups B, C, & D; Div 1 & 2, Class II, Groups E, F, & G. II 2 G Ex d IIB + H2 T6 Gb
    • Div 1 & 2, Class I, Groups B, C, & D; Div 1 & 2, Class II, Groups E, F, & G. II 2 G Ex d IIB + H2 T2 Gb
  • Operating Force (OF)
    • 12,2 N [2.75 lb]
    • 1,11 N [2.5 lb] max.
    • 13,34 N [3.0 lb] max.
    • 2,22 N to 6,67 N [0.5 lbs to 1.5 lbs]
    • 15,57 N [3.5 lb] max.
    • 0,56 N [2 oz] max.
    • 8,90 N [2 lb] max.
    • 3,61 N to 8,90 N [0.81 lbs to 2.0 lbs]
    • 0,22 Nm [31.25 in/oz]
    • 3,34 N to 8,90 N [0.75 lbs to 2.0 lbs]
    • 2,22 N to 5,56 N [0.5 lbs to 1.25 lbs]
    • 3,34 N [0.75 lb] max.
    • 7,78 N [1.75 lb] max.
  • Ampere Rating
    • 15 A Ind./ 0.5 A Res./0.25 A Res.
    • 10 A Ind./0.3 A Res./0.15 A Res.
    • 20 A Ind./ 0.5 A Res./0.25 A Res.
    • 1 A Ind.
  • Circuitry
    • 2NC 2NO DPDT Snap Action
    • 1NC 1NO SPDT Snap Action
    • 1NC 1NO SPDT Maintained
  • Overtravel (OT)
    • 25° max.
    • 3,18 mm [0.125 in] min.
    • 90° max.
  • Sealing
    • NEMA 1
  • UNSPSC Commodity
    • 39122213 Limit Switch
  • IEC Ex
    • Yes
  • Termination Type
    • 0.5 in - 14NPT Conduit
    • 0,91 m (3 ft.) Leadwires
  • Product Type
    • MICRO SWITCH Explosion-Proof Limit Switches
  • Housing Type
    • EX
  • Differential Travel (DT)
    • 0,3 mm [0.012 in] (4°) max
    • 0,23 mm [0.009 in] max.
    • 0,18 mm [0.007 in] (0.25°) max.
  • Supply Voltage
    • 125 Vac
    • 125 Vac, 250 Vac/125 Vdc/250 Vdc
    • 125 Vac, 250 Vac, 480 Vac/125 Vdc/250 Vdc
  • Series Name
    • EX
  • Agency Approvals and Standards
    • UL, CSA, ATEX, IEC Ex, INMETRO
    • UL, CSA, INMETRO
  • UNSPSC Code
    • 39122213
  • Actuator
    • Side Rotary
    • Top Plunger
    • Manual

Others

  • Operating Temperature
    • -40°C to 71°C [-40°F to 160°F]
    • -40°C to 204°C [-40°F to 400°F]
  • Sealed
    • Explosion-proof
  • Pretravel (PT)
    • 5,56 mm [0.219 in] (8°) max.
    • 1,27 mm [0.050 in] max.
  • Housing Material
    • Aluminum
  • Approvals
    • Div 1 & 2, Class I, Groups B, C, & D; Div 1 & 2, Class II, Groups E, F, & G. II 2 G Ex d IIB + H2 T6 Gb
    • Div 1 & 2, Class I, Groups B, C, & D; Div 1 & 2, Class II, Groups E, F, & G. II 2 G Ex d IIB + H2 T2 Gb
  • Operating Force (OF)
    • 12,2 N [2.75 lb]
    • 1,11 N [2.5 lb] max.
    • 13,34 N [3.0 lb] max.
    • 2,22 N to 6,67 N [0.5 lbs to 1.5 lbs]
    • 15,57 N [3.5 lb] max.
    • 0,56 N [2 oz] max.
    • 8,90 N [2 lb] max.
    • 3,61 N to 8,90 N [0.81 lbs to 2.0 lbs]
    • 0,22 Nm [31.25 in/oz]
    • 3,34 N to 8,90 N [0.75 lbs to 2.0 lbs]
    • 2,22 N to 5,56 N [0.5 lbs to 1.25 lbs]
    • 3,34 N [0.75 lb] max.
    • 7,78 N [1.75 lb] max.
  • Ampere Rating
    • 15 A Ind./ 0.5 A Res./0.25 A Res.
    • 10 A Ind./0.3 A Res./0.15 A Res.
    • 20 A Ind./ 0.5 A Res./0.25 A Res.
    • 1 A Ind.
  • Circuitry
    • 2NC 2NO DPDT Snap Action
    • 1NC 1NO SPDT Snap Action
    • 1NC 1NO SPDT Maintained
  • Overtravel (OT)
    • 25° max.
    • 3,18 mm [0.125 in] min.
    • 90° max.
  • Sealing
    • NEMA 1
  • UNSPSC Commodity
    • 39122213 Limit Switch
  • IEC Ex
    • Yes
  • Termination Type
    • 0.5 in - 14NPT Conduit
    • 0,91 m (3 ft.) Leadwires
  • Product Type
    • MICRO SWITCH Explosion-Proof Limit Switches
  • Housing Type
    • EX
  • Differential Travel (DT)
    • 0,3 mm [0.012 in] (4°) max
    • 0,23 mm [0.009 in] max.
    • 0,18 mm [0.007 in] (0.25°) max.
  • Supply Voltage
    • 125 Vac
    • 125 Vac, 250 Vac/125 Vdc/250 Vdc
    • 125 Vac, 250 Vac, 480 Vac/125 Vdc/250 Vdc
  • Series Name
    • EX
  • Agency Approvals and Standards
    • UL, CSA, ATEX, IEC Ex, INMETRO
    • UL, CSA, INMETRO
  • UNSPSC Code
    • 39122213
  • Actuator
    • Side Rotary
    • Top Plunger
    • Manual
  • Operating Temperature : -40°C to 71°C [-40°F to 160°F]|-40°C to 204°C [-40°F to 400°F]
  • Sealed : Explosion-proof
  • Pretravel (PT) : 5,56 mm [0.219 in] (8°) max.|1,27 mm [0.050 in] max.
  • Housing Material : Aluminum
  • Approvals : Div 1 & 2, Class I, Groups B, C, & D; Div 1 & 2, Class II, Groups E, F, & G. II 2 G Ex d IIB + H2 T6 Gb|Div 1 & 2, Class I, Groups B, C, & D; Div 1 & 2, Class II, Groups E, F, & G. II 2 G Ex d IIB + H2 T2 Gb
  • Operating Force (OF) : 12,2 N [2.75 lb]|1,11 N [2.5 lb] max.|13,34 N [3.0 lb] max.|2,22 N to 6,67 N [0.5 lbs to 1.5 lbs]|15,57 N [3.5 lb] max.|0,56 N [2 oz] max.|8,90 N [2 lb] max.|3,61 N to 8,90 N [0.81 lbs to 2.0 lbs]|0,22 Nm [31.25 in/oz]|3,34 N to 8,90 N [0.75 lbs to 2.0 lbs]|2,22 N to 5,56 N [0.5 lbs to 1.25 lbs]|3,34 N [0.75 lb] max.|7,78 N [1.75 lb] max.
  • Ampere Rating : 15 A Ind./ 0.5 A Res./0.25 A Res.|10 A Ind./0.3 A Res./0.15 A Res.|20 A Ind./ 0.5 A Res./0.25 A Res.|1 A Ind.
  • Circuitry : 2NC 2NO DPDT Snap Action|1NC 1NO SPDT Snap Action|1NC 1NO SPDT Maintained
  • Overtravel (OT) : 25° max.|3,18 mm [0.125 in] min.|90° max.
  • Sealing : NEMA 1
  • UNSPSC Commodity : 39122213 Limit Switch
  • IEC Ex : Yes
  • Termination Type : 0.5 in - 14NPT Conduit|0,91 m (3 ft.) Leadwires
  • Product Type : MICRO SWITCH Explosion-Proof Limit Switches
  • Housing Type : EX
  • Differential Travel (DT) : 0,3 mm [0.012 in] (4°) max|0,23 mm [0.009 in] max.|0,18 mm [0.007 in] (0.25°) max.
  • Supply Voltage : 125 Vac|125 Vac, 250 Vac/125 Vdc/250 Vdc|125 Vac, 250 Vac, 480 Vac/125 Vdc/250 Vdc
  • Series Name : EX
  • Agency Approvals and Standards : UL, CSA, ATEX, IEC Ex, INMETRO|UL, CSA, INMETRO
  • UNSPSC Code : 39122213
  • Actuator : Side Rotary|Top Plunger|Manual
Data Sheet
Name
Description
File Size
Date
Size
MICRO SWITCH EX Series Hazardous Location Limit Switches
788.84 KB
9/10/2020
PDF 788.84 KB
Manuals and Guides
Name
Description
File Size
Date
Size
PK 88012: EX and OP - replacement parts
140.77 KB
9/10/2020
PDF 140.77 KB
50009662: EX Series Explosion-Proof Limit Switches
2.54 MB
9/10/2020
PDF 2.54 MB
Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches
2.77 MB
12/3/2020
PDF 2.77 MB
Regulatory Information
Name
Description
File Size
Date
Size
MICRO SWITCH Hazardous Location Approvals Matrix
529.26 KB
12/3/2020
PDF 529.26 KB
Brochure
Name
Description
File Size
Date
Size
Oil and Gas Brochure
3.4 MB
12/3/2020
PDF 3.4 MB
MICRO SWITCH Hazardous Area Switches Brochure
24.3 MB
12/3/2020
PDF 24.3 MB
White Paper
Name
Description
File Size
Date
Size
White Paper: How Switches Can Stop Machines from Going Boom
2.56 MB
12/3/2020
PDF 2.56 MB
Application Note
Name
Description
File Size
Date
Size
Sensors and Switches in Valves and Flowmeters
1.79 MB
12/16/2020
PDF 1.79 MB
Sensors and Switches in Oil Rig Applications
6.35 MB
12/3/2020
PDF 6.35 MB
Case Study
Name
Description
File Size
Date
Size
Limit Switch for Hazardous Locations Provides Regulatory Compliance
149.49 KB
9/10/2020
PDF 149.49 KB
Name
Description
File Size
Date
Size
PK 88012: EX and OP - replacement parts
140.77 KB
9/10/2020
PDF 140.77 KB
Sensors and Switches in Valves and Flowmeters
1.79 MB
12/16/2020
PDF 1.79 MB
Limit Switch for Hazardous Locations Provides Regulatory Compliance
149.49 KB
9/10/2020
PDF 149.49 KB
50009662: EX Series Explosion-Proof Limit Switches
2.54 MB
9/10/2020
PDF 2.54 MB
MICRO SWITCH EX Series Hazardous Location Limit Switches
788.84 KB
9/10/2020
PDF 788.84 KB
MICRO SWITCH Hazardous Location Approvals Matrix
529.26 KB
12/3/2020
PDF 529.26 KB
Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches
2.77 MB
12/3/2020
PDF 2.77 MB
White Paper: How Switches Can Stop Machines from Going Boom
2.56 MB
12/3/2020
PDF 2.56 MB
Sensors and Switches in Oil Rig Applications
6.35 MB
12/3/2020
PDF 6.35 MB
Oil and Gas Brochure
3.4 MB
12/3/2020
PDF 3.4 MB
MICRO SWITCH Hazardous Area Switches Brochure
24.3 MB
12/3/2020
PDF 24.3 MB