Board Mount Pressure Sensors

TruStability™ HSC Series

Compensated. ±1 %FSS to ±3 %FSS TEB. Ultra-low (differential, gage), low (absolute, diff., gage). Digital or analog output. DIP, SIP, SMT

TruStability™ HSC Series

Distributor Inventory

Pressure Ranges
  • ±1.6 mbar to ±10 bar | ±160 Pa to ±1 MPa | ±0.5 inH20 to ±150 psi

High-accuracy Silicon Ceramic (HSC) Series is a piezoresistive silicon pressure sensor offering a ratiometric analog or digital output for reading pressure over the specified full scale pressure span and temperature range. The HSC Series is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects, and nonlinearity using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure are updated at approximately 1 kHz for analog and 2 kHz for digital.

The HSC Series is calibrated over the temperature range of 0 °C to 50 °C [32 °F to 122 °F]. The sensor is characterized for operation from a single power supply of either 3.3 Vdc or 5.0 Vdc.

These sensors measure absolute, gage, or differential pressures. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. Gage versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere. Differential versions allow measurement of pressure between the two pressure ports.

TruStability® pressure sensors are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases. Available options extend the performance of these sensors to non-corrosive, non-ionic liquids for pressure ranges above 40 mbar | 4 kPa | 20 inH2O.

All products are designed and manufactured according to standards in ISO 9001.

Others

  • Response Time
    • 1 ms max.
  • Storage Temperature
    • -40°C to 85°C [-40°F to 185°F]
    • -40 °C to 85 °C [-40 °F to 185 °F]
  • Shock
    • MIL-STD-202F, Method 213B, Condition F
  • Operating Temperature
    • -20°C to 85°C [-4°F to 185°F]
    • -20 °C to 85 °C [-4 °F to 185 °F]
  • Measurement Type
    • Differential
    • Gage
    • Absolute
  • Vibration
    • MIL-STD-202F, Curve AK (20.7 g random)
  • Pressure Range
    • 0 bar to 10 bar
    • 0 psi to 100 psi
    • 0 mbar to 60 mbar
  • Transfer Function
    • 10% to 90% of 2<sup>14</sup> counts
    • 10% to 90% Vsupply
    • 10% to 90% of Vsupply
  • Supply Current
    • 2 mA typ.
    • 1.6 mA
    • 1.6 mA typ.
    • 2 mA
  • Port Style
    • AA: dual axial barbed ports, opposite sides
    • HN: fastener mount, single radial barbed port
    • DR: dual radial barbed ports, opposite sides
    • NN: no ports
    • RR: dual radial barbed ports, same side
    • MN: manifold mount, outer diameter seal
    • RN: single radial barbed port
    • AN: single axial barbed port
    • FF: fastener mount, dual axial barbed ports, opposite sides
    • LN: single axial barbless port
    • GN: ribbed fastener mount, single axial barbed port
    • SN: manifold mount, inner diameter seal
    • HH: fastener mount, dual radial barbed ports, same side
  • Accuracy (Best Fit Straight Line)
    • ±0.25%
  • Package Type
    • DIP
    • SMT
    • SIP
  • Media Compatibility
    • Dry gases only
    • Liquid media on port 1
  • Compensated Temperature Range
    • 0°C to 50°C [32°F to 122°F]
    • 0 °C to 50 °C [32 °F to 122 °F]
  • Temperature Compensation
    • Yes
  • Signal Conditioning
    • Amplified
  • Output
    • Digital I<sup>2</sup>C address: 0x68
    • Digital I<sup>2</sup>C address: 0x38
    • Digital I<sup>2</sup>C address: 0x48
    • Digital I<sup>2</sup>C address: 0x28
    • Digital I<sup>2</sup>C address 0x28
    • Digital SPI
    • Analog
    • Digital I<sup>2</sup>C address: 0x78
    • Digital I²C address: 0x28
  • Supply Voltage
    • 5 Vdc
    • 3.3 Vdc
  • Series Name
    • TruStability™ HSC
    • TruStability® HSC
  • Output Calibration
    • Yes
  • Total Error Band
    • ±3 %FSS
    • ±1 %FSS
    • ±2.5 %FSS
    • ±1.5 %FSS

Others

  • Response Time
    • 1 ms max.
  • Storage Temperature
    • -40°C to 85°C [-40°F to 185°F]
    • -40 °C to 85 °C [-40 °F to 185 °F]
  • Shock
    • MIL-STD-202F, Method 213B, Condition F
  • Operating Temperature
    • -20°C to 85°C [-4°F to 185°F]
    • -20 °C to 85 °C [-4 °F to 185 °F]
  • Measurement Type
    • Differential
    • Gage
    • Absolute
  • Vibration
    • MIL-STD-202F, Curve AK (20.7 g random)
  • Pressure Range
    • 0 bar to 10 bar
    • 0 psi to 100 psi
    • 0 mbar to 60 mbar
  • Transfer Function
    • 10% to 90% of 2<sup>14</sup> counts
    • 10% to 90% Vsupply
    • 10% to 90% of Vsupply
  • Supply Current
    • 2 mA typ.
    • 1.6 mA
    • 1.6 mA typ.
    • 2 mA
  • Port Style
    • AA: dual axial barbed ports, opposite sides
    • HN: fastener mount, single radial barbed port
    • DR: dual radial barbed ports, opposite sides
    • NN: no ports
    • RR: dual radial barbed ports, same side
    • MN: manifold mount, outer diameter seal
    • RN: single radial barbed port
    • AN: single axial barbed port
    • FF: fastener mount, dual axial barbed ports, opposite sides
    • LN: single axial barbless port
    • GN: ribbed fastener mount, single axial barbed port
    • SN: manifold mount, inner diameter seal
    • HH: fastener mount, dual radial barbed ports, same side
  • Accuracy (Best Fit Straight Line)
    • ±0.25%
  • Package Type
    • DIP
    • SMT
    • SIP
  • Media Compatibility
    • Dry gases only
    • Liquid media on port 1
  • Compensated Temperature Range
    • 0°C to 50°C [32°F to 122°F]
    • 0 °C to 50 °C [32 °F to 122 °F]
  • Temperature Compensation
    • Yes
  • Signal Conditioning
    • Amplified
  • Output
    • Digital I<sup>2</sup>C address: 0x68
    • Digital I<sup>2</sup>C address: 0x38
    • Digital I<sup>2</sup>C address: 0x48
    • Digital I<sup>2</sup>C address: 0x28
    • Digital I<sup>2</sup>C address 0x28
    • Digital SPI
    • Analog
    • Digital I<sup>2</sup>C address: 0x78
    • Digital I²C address: 0x28
  • Supply Voltage
    • 5 Vdc
    • 3.3 Vdc
  • Series Name
    • TruStability™ HSC
    • TruStability® HSC
  • Output Calibration
    • Yes
  • Total Error Band
    • ±3 %FSS
    • ±1 %FSS
    • ±2.5 %FSS
    • ±1.5 %FSS
  • Response Time : 1 ms max.
  • Storage Temperature : -40°C to 85°C [-40°F to 185°F]|-40 °C to 85 °C [-40 °F to 185 °F]
  • Shock : MIL-STD-202F, Method 213B, Condition F
  • Operating Temperature : -20°C to 85°C [-4°F to 185°F]|-20 °C to 85 °C [-4 °F to 185 °F]
  • Measurement Type : Differential|Gage|Absolute
  • Vibration : MIL-STD-202F, Curve AK (20.7 g random)
  • Pressure Range : 0 bar to 10 bar|0 psi to 100 psi|0 mbar to 60 mbar
  • Transfer Function : 10% to 90% of 214 counts|10% to 90% Vsupply|10% to 90% of Vsupply
  • Supply Current : 2 mA typ.|1.6 mA|1.6 mA typ.|2 mA
  • Port Style : AA: dual axial barbed ports, opposite sides|HN: fastener mount, single radial barbed port|DR: dual radial barbed ports, opposite sides|NN: no ports|RR: dual radial barbed ports, same side|MN: manifold mount, outer diameter seal|RN: single radial barbed port|AN: single axial barbed port|FF: fastener mount, dual axial barbed ports, opposite sides|LN: single axial barbless port|GN: ribbed fastener mount, single axial barbed port|SN: manifold mount, inner diameter seal|HH: fastener mount, dual radial barbed ports, same side
  • Accuracy (Best Fit Straight Line) : ±0.25%
  • Package Type : DIP|SMT|SIP
  • Media Compatibility : Dry gases only|Liquid media on port 1
  • Compensated Temperature Range : 0°C to 50°C [32°F to 122°F]|0 °C to 50 °C [32 °F to 122 °F]
  • Temperature Compensation : Yes
  • Signal Conditioning : Amplified
  • Output : Digital I2C address: 0x68|Digital I2C address: 0x38|Digital I2C address: 0x48|Digital I2C address: 0x28|Digital I2C address 0x28|Digital SPI|Analog|Digital I2C address: 0x78|Digital I²C address: 0x28
  • Supply Voltage : 5 Vdc|3.3 Vdc
  • Series Name : TruStability™ HSC|TruStability® HSC
  • Output Calibration : Yes
  • Total Error Band : ±3 %FSS|±1 %FSS|±2.5 %FSS|±1.5 %FSS
White Paper
Name
Description
File Size
Date
Size
The Economics of Accuracy in Low-Cost, High-Volume Medical Applications
2.25 MB
1/11/2021
PDF 2.25 MB
Measuring Pressure in Chemistry Analyzers
2.72 MB
1/11/2021
PDF 2.72 MB
Application Note
Name
Description
File Size
Date
Size
Solutions for Oxygen Concentrators
2.3 MB
1/11/2021
PDF 2.3 MB
Sensors and Switches: Solutions for Medical Applications
1.35 MB
1/11/2021
PDF 1.35 MB
Solutions for Hemodialysis Machines
2.65 MB
9/10/2020
PDF 2.65 MB
Solutions for Ventilators
2.79 MB
1/11/2021
PDF 2.79 MB
Sensors and Switches in Chemistry and Immunoassay Analyzers
1.23 MB
9/10/2020
PDF 1.23 MB
Sensors in Sleep Apnea Machines
1.88 MB
1/11/2021
PDF 1.88 MB
Technical Note
Name
Description
File Size
Date
Size
TruStability™ SMT RR highres photo.jpg
72.54 KB
9/10/2020
72.54 KB
TruStability™ DIP RR highres photo.jpg
87.27 KB
9/10/2020
87.27 KB
Sleep Mode for Use with Honeywell Digital Pressure Sensors: ASDX Series, APB Series, and Trustability® HSC, SSC Series
329.92 KB
1/11/2021
PDF 329.92 KB
Pressure Sensor Surface Mount (SMT) Guidelines
1.69 MB
1/11/2021
PDF 1.69 MB
TruStability™ SMT AN highres photo.jpg
84.37 KB
9/10/2020
84.37 KB
Auto-Zero Calibration Technique for Pressure Sensors
721.93 KB
1/11/2021
PDF 721.93 KB
Diagnostics for TruStability™ HSC and SSC Series, and Basic ABP Series Board Mount Pressure Sensors; FSA Series Force Sensors
186.84 KB
1/11/2021
PDF 186.84 KB
TruStability™ DIP RN highres photo.jpg
70.48 KB
9/10/2020
70.48 KB
TruStability™ DIP AN highres photo.jpg
106.9 KB
9/10/2020
106.9 KB
TruStability™ SIP HN highres photo.jpg
136.19 KB
9/10/2020
136.19 KB
TruStability™ SMT LN highres photo.jpg
108.4 KB
9/10/2020
108.4 KB
TruStability™ SIP RR highres photo.jpg
64.55 KB
9/10/2020
64.55 KB
TruStability™ SMT RN highres photo.jpg
73.16 KB
9/10/2020
73.16 KB
TruStability™ SIP AA highres photo.jpg
44.2 KB
9/10/2020
44.2 KB
TruStability™ SIP SN highres photo.jpg
157.38 KB
9/10/2020
157.38 KB
Pneumatic Interface Recommendations for TruStability® Board Mount Pressure Sensors, HSC, SSC, TSC, NSC Series Technical Note
58.35 KB
9/10/2020
PDF 58.35 KB
I2C Communications with Honeywell Digital Output Pressure Sensors
212.26 KB
9/10/2020
PDF 212.26 KB
TruStability® Pressure Sensor Liquid Media Compatibility and Guidelines
181.01 KB
9/10/2020
PDF 181.01 KB
Energy and Environmental Design Trends
823.31 KB
1/11/2021
PDF 823.31 KB
Pressure or Airflow Sensors?
553.46 KB
1/11/2021
PDF 553.46 KB
TruStability™ SIP FF CAD Model.zip
51.06 KB
10/19/2020
51.06 KB
TruStability™ SMT RN CAD Model.zip
239.01 KB
10/19/2020
239.01 KB
TruStability™ SIP AA CAD Model.zip
75.91 KB
10/19/2020
75.91 KB
TruStability™ DIP LN CAD Model.zip
187.57 KB
10/19/2020
187.57 KB
TruStability™ SIP HH CAD Model.zip
42.59 KB
10/19/2020
42.59 KB
TruStability™ DIP AN CAD Model.zip
180.9 KB
10/19/2020
180.9 KB
TruStability™ DIP RR CAD Model.zip
183.81 KB
10/19/2020
183.81 KB
TruStability™ SIP MN CAD Model.zip
56.5 KB
10/19/2020
56.5 KB
TruStability™ SIP HN CAD Model.zip
112.37 KB
10/19/2020
112.37 KB
TruStability™ SMT NN CAD Model.zip
252.04 KB
10/19/2020
252.04 KB
TruStability™ SIP AN CAD Model.zip
90.7 KB
10/19/2020
90.7 KB
TruStability™ SIP SN CAD Model.zip
72.27 KB
10/19/2020
72.27 KB
TruStability™ SMT RR CAD Model.zip
231.81 KB
10/19/2020
231.81 KB
Data Sheet
Name
Description
File Size
Date
Size
TruStability® Board Mount Pressure Sensors: HSC Series
4.55 MB
9/10/2020
PDF 4.55 MB
Manuals and Guides
Name
Description
File Size
Date
Size
TruStability® Board Mount Pressure Sensors: HSC Series and SSC Series
3.75 MB
9/10/2020
PDF 3.75 MB
Brochure
Name
Description
File Size
Date
Size
Airflow, Force, and Pressure Sensors Range Guide
2.03 MB
1/11/2021
PDF 2.03 MB
Others
Name
Description
File Size
Date
Size
TruStability™ SIP FF lowres photo.jpg
8.9 KB
9/10/2020
8.9 KB
TruStability™ DIP DR lowres photo.jpg
11.75 KB
9/10/2020
11.75 KB
Name
Description
File Size
Date
Size
The Economics of Accuracy in Low-Cost, High-Volume Medical Applications
2.25 MB
1/11/2021
PDF 2.25 MB
Solutions for Oxygen Concentrators
2.3 MB
1/11/2021
PDF 2.3 MB
Sensors and Switches: Solutions for Medical Applications
1.35 MB
1/11/2021
PDF 1.35 MB
Solutions for Hemodialysis Machines
2.65 MB
9/10/2020
PDF 2.65 MB
Solutions for Ventilators
2.79 MB
1/11/2021
PDF 2.79 MB
Sensors and Switches in Chemistry and Immunoassay Analyzers
1.23 MB
9/10/2020
PDF 1.23 MB
TruStability™ SMT RR highres photo.jpg
72.54 KB
9/10/2020
72.54 KB
TruStability® Board Mount Pressure Sensors: HSC Series
4.55 MB
9/10/2020
PDF 4.55 MB
TruStability™ DIP RR highres photo.jpg
87.27 KB
9/10/2020
87.27 KB
Sleep Mode for Use with Honeywell Digital Pressure Sensors: ASDX Series, APB Series, and Trustability® HSC, SSC Series
329.92 KB
1/11/2021
PDF 329.92 KB
TruStability™ SIP FF lowres photo.jpg
8.9 KB
9/10/2020
8.9 KB
Pressure Sensor Surface Mount (SMT) Guidelines
1.69 MB
1/11/2021
PDF 1.69 MB
TruStability™ SMT AN highres photo.jpg
84.37 KB
9/10/2020
84.37 KB
Auto-Zero Calibration Technique for Pressure Sensors
721.93 KB
1/11/2021
PDF 721.93 KB
TruStability™ DIP DR lowres photo.jpg
11.75 KB
9/10/2020
11.75 KB
Diagnostics for TruStability™ HSC and SSC Series, and Basic ABP Series Board Mount Pressure Sensors; FSA Series Force Sensors
186.84 KB
1/11/2021
PDF 186.84 KB
TruStability™ DIP RN highres photo.jpg
70.48 KB
9/10/2020
70.48 KB
TruStability™ DIP AN highres photo.jpg
106.9 KB
9/10/2020
106.9 KB
TruStability™ SIP HN highres photo.jpg
136.19 KB
9/10/2020
136.19 KB
TruStability™ SMT LN highres photo.jpg
108.4 KB
9/10/2020
108.4 KB
TruStability™ SIP RR highres photo.jpg
64.55 KB
9/10/2020
64.55 KB
TruStability™ SMT RN highres photo.jpg
73.16 KB
9/10/2020
73.16 KB
TruStability™ SIP AA highres photo.jpg
44.2 KB
9/10/2020
44.2 KB
TruStability™ SIP SN highres photo.jpg
157.38 KB
9/10/2020
157.38 KB
Pneumatic Interface Recommendations for TruStability® Board Mount Pressure Sensors, HSC, SSC, TSC, NSC Series Technical Note
58.35 KB
9/10/2020
PDF 58.35 KB
I2C Communications with Honeywell Digital Output Pressure Sensors
212.26 KB
9/10/2020
PDF 212.26 KB
Measuring Pressure in Chemistry Analyzers
2.72 MB
1/11/2021
PDF 2.72 MB
TruStability® Board Mount Pressure Sensors: HSC Series and SSC Series
3.75 MB
9/10/2020
PDF 3.75 MB
TruStability® Pressure Sensor Liquid Media Compatibility and Guidelines
181.01 KB
9/10/2020
PDF 181.01 KB
Energy and Environmental Design Trends
823.31 KB
1/11/2021
PDF 823.31 KB
Sensors in Sleep Apnea Machines
1.88 MB
1/11/2021
PDF 1.88 MB
Pressure or Airflow Sensors?
553.46 KB
1/11/2021
PDF 553.46 KB
Airflow, Force, and Pressure Sensors Range Guide
2.03 MB
1/11/2021
PDF 2.03 MB
TruStability™ SIP FF CAD Model.zip
51.06 KB
10/19/2020
51.06 KB
TruStability™ SMT RN CAD Model.zip
239.01 KB
10/19/2020
239.01 KB
TruStability™ SIP AA CAD Model.zip
75.91 KB
10/19/2020
75.91 KB
TruStability™ DIP LN CAD Model.zip
187.57 KB
10/19/2020
187.57 KB
TruStability™ SIP HH CAD Model.zip
42.59 KB
10/19/2020
42.59 KB
TruStability™ DIP AN CAD Model.zip
180.9 KB
10/19/2020
180.9 KB
TruStability™ DIP RR CAD Model.zip
183.81 KB
10/19/2020
183.81 KB
TruStability™ SIP MN CAD Model.zip
56.5 KB
10/19/2020
56.5 KB
TruStability™ SIP HN CAD Model.zip
112.37 KB
10/19/2020
112.37 KB
TruStability™ SMT NN CAD Model.zip
252.04 KB
10/19/2020
252.04 KB
TruStability™ SIP AN CAD Model.zip
90.7 KB
10/19/2020
90.7 KB
TruStability™ SIP SN CAD Model.zip
72.27 KB
10/19/2020
72.27 KB
TruStability™ SMT RR CAD Model.zip
231.81 KB
10/19/2020
231.81 KB