/content/sps/ru/ru/search-results.html

Portables

MultiRAE

Wireless, portable multi-gas monitor with advanced VOC detection

Обзор продукта

MultiRAE is the most advanced portable chemical detector on the market. With the flexibility of up to six gas sensors and the convenience of wireless portability, this multi-gas monitor is versatile and customizable, while delivering real-time access to instrument readings and alarm status from any location. Choose from 25 sensor options including LEL, PID, NDIR, and exotics that can be easily changed in the field. With five built-in alarms, including man down, and wireless connectivity to your command center, MultiRAE delivers vital information for fast incident response.

Features and Benefits:

  • Optional integrated wireless
  • 25 field-interchangeable sensor options, including PID, NDIR, and exotics like ammonia, chlorine, and formaldehyde
  • Five local and remote alarms, including man down
  • Dust-tight and waterproof (IP65-rated)
  • Rugged design
  • Onboard gas libraries include 190 VOCs and 55 combustible gases
  • Longest battery run-time in its class
  • Intuitive, icon-driven interface
  • Flippable screen
  • Large buttons for easy navigation even with up to three glove layers
  • Continuous data logging — six months for five sensors 24/7
  • Fully automated bump testing and calibration with AutoRAE 2
  • Device Management with Honeywell Sotera™ Express

Application:

  • Clandestine Labs
  • Confined Space Entry
  • Emergency Response
  • Environmental Cleanups/ Remediation
  • Exploration
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Residential Calls
  • Urban Search & Rescue
  • Venue Protection
Xарактеристики

Brand

  • Brand
    • RAE

Dimensions

  • Weight
    • 31
    • 880 gram

Category

  • Sub-Category
    • Premium-Gas

Dimension & Weight

  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Range

  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
    • NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
  • Humidity Range
    • 0%-95% percent

Alarm

  • Alarm Type
    • Audible, Visual, Vibrating
    • Audible- Visual- Vibrating

Battery & Charging

  • Battery Run Time
    • 12-18 hours

Certifications

  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
    • CSA: Class I- Division 1- Groups A- B- C- and D- T4

Datalogging

  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)

Features & Benefits

  • Benefits
    • Highly versatile and customizable

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • 3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected

Sampling

  • Sampling Pump Range
    • 100ft (30m) meter

Warranty

  • Warranty
    • Four years on Liq O2 sensors

Wireless

  • Wireless Technology
    • MESH, Wifi, BLE
    • MESH- Wifi- BLE

Additional Specifications

  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
    • NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2
  • Ingress Protection
    • IP65

Others

  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50 degree Celsius
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit

Brand

  • Brand
    • RAE

Dimensions

  • Weight
    • 31
    • 880 gram

Category

  • Sub-Category
    • Premium-Gas

Dimension & Weight

  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Range

  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
    • NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
  • Humidity Range
    • 0%-95% percent

Alarm

  • Alarm Type
    • Audible, Visual, Vibrating
    • Audible- Visual- Vibrating

Battery & Charging

  • Battery Run Time
    • 12-18 hours

Certifications

  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
    • CSA: Class I- Division 1- Groups A- B- C- and D- T4

Datalogging

  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)

Features & Benefits

  • Benefits
    • Highly versatile and customizable

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • 3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected

Sampling

  • Sampling Pump Range
    • 100ft (30m) meter

Warranty

  • Warranty
    • Four years on Liq O2 sensors

Wireless

  • Wireless Technology
    • MESH, Wifi, BLE
    • MESH- Wifi- BLE

Additional Specifications

  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
    • NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2
  • Ingress Protection
    • IP65

Others

  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50 degree Celsius
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Brand : RAE
  • Weight : 31|880 gram
  • Maximum Temperature : 122 degree Fahrenheit|50 degree Celsius
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Sub-Category : Premium-Gas
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)|NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
  • Humidity Range : 0%-95% percent
  • Alarm Type : Audible, Visual, Vibrating|Audible- Visual- Vibrating
  • Battery Run Time : 12-18 hours
  • Standards : CSA: Class I, Division 1, Groups A, B, C, and D, T4|CSA: Class I- Division 1- Groups A- B- C- and D- T4
  • Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)|Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)
  • Benefits : Highly versatile and customizable
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected|3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected
  • Sampling Pump Range : 100ft (30m) meter
  • Warranty : Four years on Liq O2 sensors
  • Wireless Technology : MESH, Wifi, BLE|MESH- Wifi- BLE
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2|NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2
  • Ingress Protection : IP65
Технические характеристики
Name
Description
File Size
Date
Size
MultiRAE Data Sheet
application/pdf 124.22 KB
11/3/2021
124.22 KB
Руководства и инструкции
Name
Description
File Size
Date
Size
MultiRAE User Manual - EN
application/pdf 13.7 MB
5/2/2024
13.7 MB
MultiRAE User's Guide - IT
application/pdf 4.64 MB
11/3/2021
4.64 MB
MultiRAE User's Guide - ES
application/pdf 4.55 MB
11/3/2021
4.55 MB
MultiRAE (Pumped) QuickStart Guide
application/pdf 302.5 KB
11/3/2021
302.5 KB
MultiRAE User's Guide - DE
application/pdf 4.56 MB
11/3/2021
4.56 MB
MultiRAE User's Guide - NL
application/pdf 4.26 MB
11/3/2021
4.26 MB
MultiRAE User's Guide - RU
application/pdf 5.05 MB
11/3/2021
5.05 MB
MultiRAE User's Guide - FR
application/pdf 4.63 MB
11/3/2021
4.63 MB
Техническое примечание
Name
Description
File Size
Date
Size
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
11/3/2021
795.02 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
11/3/2021
125.12 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
11/3/2021
814.89 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
11/3/2021
911.54 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
11/3/2021
788.83 KB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
11/3/2021
620.4 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
11/3/2021
609.21 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
application/pdf 976.3 KB
11/3/2021
976.3 KB
Сертификат
Name
Description
File Size
Date
Size
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
Указания по применению
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2 RU
application/pdf 737.74 KB
8/4/2022
737.74 KB
Application Note 220 - Using PIDs In Clan Lab Investigations
application/pdf 1.38 MB
8/4/2022
1.38 MB
Nota de applicaci_n 221 Uso de PID para evaluar el riesgo de exposici_n en entornos desconocidos
application/pdf 2.04 MB
8/5/2022
2.04 MB
Nota de aplicac_n 203 PID como herramientas de respuesta a materiales peligrosos
application/pdf 2.55 MB
8/5/2022
2.55 MB
Nota de aplicaci_n 219 Uso de PID para tomar decisiones relativas al 10% de LEL
application/pdf 2.08 MB
8/5/2022
2.08 MB
Nota de aplicaci_n 216 Uso de PID en ataques terroristas con agentes qu_micos
application/pdf 2.02 MB
8/5/2022
2.02 MB
Nota de aplicaci_n AP-200 PID y entrada a tanques en las alas de los aviones
application/pdf 997.82 KB
8/5/2022
997.82 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 1.75 MB
8/4/2022
1.75 MB
Application Note 202 - The ABCs Of Gases In The Industry RU
application/pdf 452.66 KB
8/4/2022
452.66 KB
Application Note 217 - Confined Spaces And The Construction Industry
application/pdf 2.22 MB
8/4/2022
2.22 MB
Application Note 221 - Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 1.33 MB
8/4/2022
1.33 MB
Application Note 219 - Using PIDs For 10% Of LEL Decisions
application/pdf 1.84 MB
8/4/2022
1.84 MB
Application Note 236 - Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 904.28 KB
8/4/2022
904.28 KB
Application Note 235 - Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 748.71 KB
8/4/2022
748.71 KB
Application 202: The ABC®s Of Gases In The Industry
application/pdf 843.47 KB
11/3/2021
843.47 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
11/3/2021
1.1 MB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
11/3/2021
1.07 MB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
application/pdf 226.06 KB
11/3/2021
226.06 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
11/3/2021
1.26 MB
Application Note 207 PIDs As Arson Investigation Tools
application/pdf 857.71 KB
11/3/2021
857.71 KB
Application Note 200: Photoionizatrion Detectors (PIDS) and Aircraft Wing Entry
application/pdf 892.2 KB
11/3/2021
892.2 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
application/pdf 1 MB
11/3/2021
1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
11/3/2021
655.59 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
11/3/2021
901.23 KB
Name
Description
File Size
Date
Size
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
11/3/2021
795.02 KB
MultiRAE User Manual - EN
application/pdf 13.7 MB
5/2/2024
13.7 MB
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2 RU
application/pdf 737.74 KB
8/4/2022
737.74 KB
Application Note 220 - Using PIDs In Clan Lab Investigations
application/pdf 1.38 MB
8/4/2022
1.38 MB
Nota de applicaci_n 221 Uso de PID para evaluar el riesgo de exposici_n en entornos desconocidos
application/pdf 2.04 MB
8/5/2022
2.04 MB
Nota de aplicac_n 203 PID como herramientas de respuesta a materiales peligrosos
application/pdf 2.55 MB
8/5/2022
2.55 MB
Nota de aplicaci_n 219 Uso de PID para tomar decisiones relativas al 10% de LEL
application/pdf 2.08 MB
8/5/2022
2.08 MB
Nota de aplicaci_n 216 Uso de PID en ataques terroristas con agentes qu_micos
application/pdf 2.02 MB
8/5/2022
2.02 MB
Nota de aplicaci_n AP-200 PID y entrada a tanques en las alas de los aviones
application/pdf 997.82 KB
8/5/2022
997.82 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 1.75 MB
8/4/2022
1.75 MB
Application Note 202 - The ABCs Of Gases In The Industry RU
application/pdf 452.66 KB
8/4/2022
452.66 KB
Application Note 217 - Confined Spaces And The Construction Industry
application/pdf 2.22 MB
8/4/2022
2.22 MB
Application Note 221 - Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 1.33 MB
8/4/2022
1.33 MB
Application Note 219 - Using PIDs For 10% Of LEL Decisions
application/pdf 1.84 MB
8/4/2022
1.84 MB
Application Note 236 - Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 904.28 KB
8/4/2022
904.28 KB
Application Note 235 - Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 748.71 KB
8/4/2022
748.71 KB
Application 202: The ABC®s Of Gases In The Industry
application/pdf 843.47 KB
11/3/2021
843.47 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
11/3/2021
125.12 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
11/3/2021
814.89 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
11/3/2021
1.1 MB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
11/3/2021
1.07 MB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
11/3/2021
911.54 KB
MultiRAE User's Guide - IT
application/pdf 4.64 MB
11/3/2021
4.64 MB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
11/3/2021
788.83 KB
MultiRAE User's Guide - ES
application/pdf 4.55 MB
11/3/2021
4.55 MB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
application/pdf 226.06 KB
11/3/2021
226.06 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
11/3/2021
1.26 MB
MultiRAE (Pumped) QuickStart Guide
application/pdf 302.5 KB
11/3/2021
302.5 KB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
11/3/2021
620.4 KB
Application Note 207 PIDs As Arson Investigation Tools
application/pdf 857.71 KB
11/3/2021
857.71 KB
MultiRAE User's Guide - DE
application/pdf 4.56 MB
11/3/2021
4.56 MB
MultiRAE User's Guide - NL
application/pdf 4.26 MB
11/3/2021
4.26 MB
MultiRAE User's Guide - RU
application/pdf 5.05 MB
11/3/2021
5.05 MB
Application Note 200: Photoionizatrion Detectors (PIDS) and Aircraft Wing Entry
application/pdf 892.2 KB
11/3/2021
892.2 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
11/3/2021
609.21 KB
MultiRAE User's Guide - FR
application/pdf 4.63 MB
11/3/2021
4.63 MB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
application/pdf 976.3 KB
11/3/2021
976.3 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
application/pdf 1 MB
11/3/2021
1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
11/3/2021
655.59 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
11/3/2021
901.23 KB
MultiRAE Data Sheet
application/pdf 124.22 KB
11/3/2021
124.22 KB
Name
Description
File Size
Date
Size
MultiRAE Data Sheet
124.22 KB
11/3/2021
MultiRAE User Manual - EN
13.7 MB
5/2/2024
MultiRAE User's Guide - IT
4.64 MB
11/3/2021
MultiRAE User's Guide - ES
4.55 MB
11/3/2021
MultiRAE (Pumped) QuickStart Guide
302.5 KB
11/3/2021
MultiRAE User's Guide - DE
4.56 MB
11/3/2021
MultiRAE User's Guide - NL
4.26 MB
11/3/2021
MultiRAE User's Guide - RU
5.05 MB
11/3/2021
MultiRAE User's Guide - FR
4.63 MB
11/3/2021
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
11/3/2021
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
11/3/2021
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
11/3/2021
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
11/3/2021
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
11/3/2021
MultiRAE Series Technical Note 106B
620.4 KB
11/3/2021
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
11/3/2021
Electrochemical Sensor Replacement & Maintenance Technical Note 151
976.3 KB
11/3/2021
MultiRAE - INMETRO Certificate of Conformity
472.03 KB
4/24/2023
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2 RU
737.74 KB
8/4/2022
Application Note 220 - Using PIDs In Clan Lab Investigations
1.38 MB
8/4/2022
Nota de applicaci_n 221 Uso de PID para evaluar el riesgo de exposici_n en entornos desconocidos
2.04 MB
8/5/2022
Nota de aplicac_n 203 PID como herramientas de respuesta a materiales peligrosos
2.55 MB
8/5/2022
Nota de aplicaci_n 219 Uso de PID para tomar decisiones relativas al 10% de LEL
2.08 MB
8/5/2022
Nota de aplicaci_n 216 Uso de PID en ataques terroristas con agentes qu_micos
2.02 MB
8/5/2022
Nota de aplicaci_n AP-200 PID y entrada a tanques en las alas de los aviones
997.82 KB
8/5/2022
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
1.75 MB
8/4/2022
Application Note 202 - The ABCs Of Gases In The Industry RU
452.66 KB
8/4/2022
Application Note 217 - Confined Spaces And The Construction Industry
2.22 MB
8/4/2022
Application Note 221 - Using PIDs To Assess Exposure Risk In Unknown Environments
1.33 MB
8/4/2022
Application Note 219 - Using PIDs For 10% Of LEL Decisions
1.84 MB
8/4/2022
Application Note 236 - Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
904.28 KB
8/4/2022
Application Note 235 - Measurement Of PGMEA Using Photoionization Detectors_12-11
748.71 KB
8/4/2022
Application 202: The ABC®s Of Gases In The Industry
843.47 KB
11/3/2021
Application Note 000: RAE Systems PID Overview
1.1 MB
11/3/2021
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
11/3/2021
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
226.06 KB
11/3/2021
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
11/3/2021
Application Note 207 PIDs As Arson Investigation Tools
857.71 KB
11/3/2021
Application Note 200: Photoionizatrion Detectors (PIDS) and Aircraft Wing Entry
892.2 KB
11/3/2021
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
11/3/2021
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
11/3/2021
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
941.33 KB
8/4/2022
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
11/3/2021
Product Number
Image
SKU
Description
alt
008-3024-000
External PID zeroing filter
alt
008-3054-000
KIT,MULTIRAE PID SENSOR
alt
010-2003-000
Colorimetric tube tip breaker
alt
010-3006-000
LP1200Kit(3RB inlets&Filt,2 gaskets)
alt
010-4003-000
GAS DETECTION TUBE & SAMPLING HANDBOOK
alt
023-3012-000
6" flexible probe(Requires M01-3224-000 to be used with MultiRAE)
alt
045-2053-000
MEMBRANE WATERPROOF,WHITE, FOR SENSOR
alt
300-0016-015
BUZZER,4.0KHZ +/-0.25KHZ,30VP-PMAX
alt
410-0036-000
Power cord (US Plug)
alt
430-0394-000
SCREW,M3X10,PAN,PHIL,SS,NC,GB818-85
Image
SKU
Description
alt
008-3024-000
External PID zeroing filter
alt
008-3054-000
KIT,MULTIRAE PID SENSOR
alt
010-2003-000
Colorimetric tube tip breaker
alt
010-3006-000
LP1200Kit(3RB inlets&Filt,2 gaskets)
alt
010-4003-000
GAS DETECTION TUBE & SAMPLING HANDBOOK
alt
023-3012-000
6" flexible probe(Requires M01-3224-000 to be used with MultiRAE)
alt
045-2053-000
MEMBRANE WATERPROOF,WHITE, FOR SENSOR
alt
300-0016-015
BUZZER,4.0KHZ +/-0.25KHZ,30VP-PMAX
alt
410-0036-000
Power cord (US Plug)
alt
430-0394-000
SCREW,M3X10,PAN,PHIL,SS,NC,GB818-85