Industrial Fixed
RAEGuard 2 PID
RAEGuard 2 PID
RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs)
Product Overview:
RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.
The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.
Features & Benefits:
• Faster response time
- Thanks to the sample flow-through design
• Reduce maintenance cost
- Easy to remove sensor module in hazardous locations without using of tools
• No false alarms
- Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution
Quick Specs:
• Digital Smart Sensor Technology
• Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm
• Operates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output
• Graphic display and LED light status indicator for fault and alarm conditions
Fire and Gas Consultancy Services
Others
- Brand
- RAE
- Sub-Category
- Gas Detection Sensors & Transmitters
Others
- Brand
- RAE
- Sub-Category
- Gas Detection Sensors & Transmitters
- Brand : RAE
- Sub-Category : Gas Detection Sensors & Transmitters
Data Sheet
Name
Description
File Size
Date
Size
Manuals and Guides
Name
Description
File Size
Date
Size
Technical Note
Name
Description
File Size
Date
Size
A Guideline for Pid Instrument Response
1.45 MB
12/4/2020
PDF 1.45 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
12/4/2020
PDF 884.37 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
12/4/2020
PDF 930.69 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
12/4/2020
PDF 787.55 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
12/4/2020
PDF 944.51 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
12/4/2020
PDF 820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 000: RAE Systems PID Overview
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
12/4/2020
PDF 826.34 KB
Name
Description
File Size
Date
Size
A Guideline for Pid Instrument Response
1.45 MB
12/4/2020
PDF 1.45 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
12/4/2020
PDF 884.37 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
12/4/2020
PDF 930.69 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
12/4/2020
PDF 787.55 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
12/4/2020
PDF 826.34 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
12/4/2020
PDF 944.51 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
12/4/2020
PDF 820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Image
SKU
Description
600-0061-000
O2 20.9 34L
600-0088-000
Butadiene 5ppm 34L
600-0002-001
Isobutylene 100ppm 103L
600-0137-000
Methane 20 34L
600-0070-000
Pentane LEL 25 34L
600-0063-000
Benzene 5ppm 34L
600-0069-000
Isobutylene 10ppm 34L
600-0024-000
Air 0 ppm 34L steel
600-0061-001
Oxygen 19% 34L steel
600-0001-000
Isobutylene 50ppm 34L