Transportable area monitor for multiple threat detection

The AreaRAE Plus provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to configure device. Plus, you’ll have vital details about threats happening in real-time—arming you with the information you need to act quickly. Features and Benefits: • Monitors up to seven threats, including VOCs, combustibles, Toxics and Oxygen • Optional meteorological sensor for tracking toxic plumes • 7R+ photoionization detector (PID) for monitoring VOCs at parts per million • Secondary radio module (Mesh) act as an communication Hub for other wireless devices • Ruggedized, portable, and weather-resistant design for harsh environments • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations Application: • Confined Space Entry • Environmental Cleanups/ Remediation • Fence Line Monitoring • Leak Detection • Plant Shutdown & Turn-Around

Others

  • Alarm Type
    • Visual, Audible, Vibrating
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Humidity Range
    • 0%-95%
  • Benefits
    • • Delivers real-time readings to Honeywell’s
  • Maximum Temperature
    • 60 degree Celsius
    • 140 degree Fahrenheit
  • Standards
    • US / Canada: Class 1, Division 2 Groups A, B, C, D
  • Weight
    • 6.5 keg
    • 14.33 US Pound
  • Sampling Pump Range
    • 100ft (30m)
  • Wireless Technology
    • BLE, MESH, WiFi
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Battery Run Time
    • 20 Hours
  • Warranty
    • Four years for O2 Liquid Oxygen sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys
  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Others

  • Alarm Type
    • Visual, Audible, Vibrating
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Humidity Range
    • 0%-95%
  • Benefits
    • • Delivers real-time readings to Honeywell’s
  • Maximum Temperature
    • 60 degree Celsius
    • 140 degree Fahrenheit
  • Standards
    • US / Canada: Class 1, Division 2 Groups A, B, C, D
  • Weight
    • 6.5 keg
    • 14.33 US Pound
  • Sampling Pump Range
    • 100ft (30m)
  • Wireless Technology
    • BLE, MESH, WiFi
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Battery Run Time
    • 20 Hours
  • Warranty
    • Four years for O2 Liquid Oxygen sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys
  • Instrument Size
    • 12.36” x 12.04” x 6.53”
  • Alarm Type : Visual, Audible, Vibrating
  • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Humidity Range : 0%-95%
  • Benefits : • Delivers real-time readings to Honeywell’s
  • Maximum Temperature : 60 degree Celsius|140 degree Fahrenheit
  • Standards : US / Canada: Class 1, Division 2 Groups A, B, C, D
  • Weight : 6.5 keg|14.33 US Pound
  • Sampling Pump Range : 100ft (30m)
  • Wireless Technology : BLE, MESH, WiFi
  • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
  • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Battery Run Time : 20 Hours
  • Warranty : Four years for O2 Liquid Oxygen sensors
  • Ingress Protection : IP65
  • User Options : 3 operation and programming keys
  • Instrument Size : 12.36” x 12.04” x 6.53”
Data Sheet
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
569.87 KB
5/18/2021
PDF 569.87 KB
Manuals and Guides
Name
Description
File Size
Date
Size
AreaRAE Plus & AreaRAE Pro User's Guide
5.65 MB
5/18/2021
PDF 5.65 MB
Firmware
Name
Description
File Size
Date
Size
AREARAE Plus / Pro v 1.08
1.57 MB
2/25/2021
1.57 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 182 Basics of Wireless Security
1.01 MB
5/18/2021
PDF 1.01 MB
AreaRAE PlusPro Technical Note 106A
428.08 KB
5/18/2021
PDF 428.08 KB
A Guideline for Pid Instrument Response
1.45 MB
5/18/2021
PDF 1.45 MB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
5/18/2021
PDF 839.32 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
5/18/2021
PDF 814.89 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
5/18/2021
PDF 884.91 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
5/18/2021
PDF 884.37 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
5/18/2021
PDF 125.12 KB
Technical Note 167_Proper Use Of Dilution Fittings On Pumped Monitors
1.02 MB
12/4/2020
PDF 1.02 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
5/18/2021
PDF 839.29 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
5/18/2021
PDF 1.09 MB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
5/18/2021
PDF 944.51 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
5/18/2021
PDF 930.69 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
5/18/2021
PDF 609.21 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
5/18/2021
PDF 950.72 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
5/18/2021
PDF 787.55 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
5/18/2021
PDF 785.04 KB
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
5/18/2021
PDF 802.28 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
5/18/2021
PDF 788.83 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
5/18/2021
PDF 795.02 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
5/18/2021
PDF 820.7 KB
White Paper
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
5/18/2021
PDF 949.42 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
5/18/2021
PDF 831.7 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
5/18/2021
PDF 1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
5/18/2021
PDF 655.59 KB
Application Note 228 - Facility and Venue Protection
1.1 MB
5/18/2021
PDF 1.1 MB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
5/18/2021
PDF 1.07 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
5/18/2021
PDF 826.34 KB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
5/18/2021
PDF 1.26 MB
Application Note 215: Gas Detection In The Marine Industries
889.61 KB
5/18/2021
PDF 889.61 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
5/18/2021
PDF 964.88 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
5/18/2021
PDF 750.69 KB
Others
Name
Description
File Size
Date
Size
Techninal Note 123_Special Diagnostic Modes For RAE Systems Instruments_10-05
899.77 KB
12/4/2020
PDF 899.77 KB
Name
Description
File Size
Date
Size
Technical Note 182 Basics of Wireless Security
1.01 MB
5/18/2021
PDF 1.01 MB
AreaRAE PlusPro Technical Note 106A
428.08 KB
5/18/2021
PDF 428.08 KB
Techninal Note 123_Special Diagnostic Modes For RAE Systems Instruments_10-05
899.77 KB
12/4/2020
PDF 899.77 KB
A Guideline for Pid Instrument Response
1.45 MB
5/18/2021
PDF 1.45 MB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
5/18/2021
PDF 839.32 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
5/18/2021
PDF 814.89 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
5/18/2021
PDF 884.91 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
5/18/2021
PDF 884.37 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
5/18/2021
PDF 125.12 KB
Technical Note 167_Proper Use Of Dilution Fittings On Pumped Monitors
1.02 MB
12/4/2020
PDF 1.02 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
5/18/2021
PDF 839.29 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
5/18/2021
PDF 1.09 MB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
5/18/2021
PDF 944.51 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
5/18/2021
PDF 930.69 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
5/18/2021
PDF 609.21 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
5/18/2021
PDF 950.72 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
5/18/2021
PDF 787.55 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
5/18/2021
PDF 785.04 KB
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
5/18/2021
PDF 802.28 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
5/18/2021
PDF 788.83 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
5/18/2021
PDF 831.7 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
5/18/2021
PDF 1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
5/18/2021
PDF 655.59 KB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
5/18/2021
PDF 949.42 KB
Application Note 228 - Facility and Venue Protection
1.1 MB
5/18/2021
PDF 1.1 MB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
5/18/2021
PDF 1.07 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
5/18/2021
PDF 826.34 KB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
5/18/2021
PDF 1.26 MB
Application Note 215: Gas Detection In The Marine Industries
889.61 KB
5/18/2021
PDF 889.61 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
5/18/2021
PDF 964.88 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
5/18/2021
PDF 750.69 KB
AreaRAE Plus Datasheet
569.87 KB
5/18/2021
PDF 569.87 KB
AreaRAE Plus & AreaRAE Pro User's Guide
5.65 MB
5/18/2021
PDF 5.65 MB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
5/18/2021
PDF 795.02 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
AREARAE Plus / Pro v 1.08
1.57 MB
2/25/2021
1.57 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
5/18/2021
PDF 820.7 KB