Portables
AreaRAE Plus
Transportable area monitor for multiple threat detection
The AreaRAE Plus provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to configure device. Plus, you’ll have vital details about threats happening in real-time—arming you with the information you need to act quickly.
Features and Benefits:
• Monitors up to seven threats, including VOCs, combustibles, Toxics and Oxygen
• Optional meteorological sensor for tracking toxic plumes
• 7R+ photoionization detector (PID) for monitoring VOCs at parts per million
• Secondary radio module (Mesh) act as an communication Hub for other wireless devices
• Ruggedized, portable, and weather-resistant design for harsh environments
• Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations
Application:
• Confined Space Entry
• Environmental Cleanups/ Remediation
• Fence Line Monitoring
• Leak Detection
• Plant Shutdown & Turn-Around
Others
- Alarm Type
- Visual, Audible, Vibrating
- Sensor Range
- VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
- Minimum Temperature
- -20 degree Fahrenheit
- Humidity Range
- 0%-95%
- Benefits
- • Delivers real-time readings to Honeywell’s
- Maximum Temperature
- 50 degree Fahrenheit
- Standards
- US / Canada: Class 1, Division 2 Groups A, B, C, D
- Weight
- 6.5 US Pound
- Sampling Pump Range
- 100ft (30m)
- Wireless Technology
- BLE, MESH, WiFi
- Gas Type
- VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
- Datalogging
- Continuous data logging (90 days for 7 gas sensors, 1 Gamma
- Battery Run Time
- 20 Hours
- Warranty
- Four years for O2 Liquid Oxygen sensors
- Ingress Protection
- IP65
- User Options
- 3 operation and programming keys
- Instrument Size
- 12.36” x 12.04” x 6.53”
Others
- Alarm Type
- Visual, Audible, Vibrating
- Sensor Range
- VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
- Minimum Temperature
- -20 degree Fahrenheit
- Humidity Range
- 0%-95%
- Benefits
- • Delivers real-time readings to Honeywell’s
- Maximum Temperature
- 50 degree Fahrenheit
- Standards
- US / Canada: Class 1, Division 2 Groups A, B, C, D
- Weight
- 6.5 US Pound
- Sampling Pump Range
- 100ft (30m)
- Wireless Technology
- BLE, MESH, WiFi
- Gas Type
- VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
- Datalogging
- Continuous data logging (90 days for 7 gas sensors, 1 Gamma
- Battery Run Time
- 20 Hours
- Warranty
- Four years for O2 Liquid Oxygen sensors
- Ingress Protection
- IP65
- User Options
- 3 operation and programming keys
- Instrument Size
- 12.36” x 12.04” x 6.53”
- Alarm Type : Visual, Audible, Vibrating
- Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
- Minimum Temperature : -20 degree Fahrenheit
- Humidity Range : 0%-95%
- Benefits : • Delivers real-time readings to Honeywell’s
- Maximum Temperature : 50 degree Fahrenheit
- Standards : US / Canada: Class 1, Division 2 Groups A, B, C, D
- Weight : 6.5 US Pound
- Sampling Pump Range : 100ft (30m)
- Wireless Technology : BLE, MESH, WiFi
- Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
- Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
- Battery Run Time : 20 Hours
- Warranty : Four years for O2 Liquid Oxygen sensors
- Ingress Protection : IP65
- User Options : 3 operation and programming keys
- Instrument Size : 12.36” x 12.04” x 6.53”
Technical Note
Name
Description
File Size
Date
Size
Technical-Note-182 Basics of Wireless Security
1.01 MB
12/4/2020
PDF 1.01 MB
Technical-Note-106_A-Guideline-for-Pid-Instrument-Response.pdf
1.45 MB
12/4/2020
PDF 1.45 MB
Technical-Note 148_Defining-The-Interval-Between-Calibration-Checks_12-15.pdf
839.32 KB
12/4/2020
PDF 839.32 KB
Technical Note 174_Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
12/4/2020
PDF 814.89 KB
Technical Note 159_Chemical Warfare Agent Measurements By PID
884.91 KB
12/4/2020
PDF 884.91 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
12/4/2020
PDF 884.37 KB
Technical Note 167_Proper Use Of Dilution Fittings On Pumped Monitors
1.02 MB
12/4/2020
PDF 1.02 MB
Technical Note 152_Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
12/4/2020
PDF 839.29 KB
Technical Note 157_Moisture Exchange Tubes For Humidity Control Of Test Gases
1.08 MB
12/4/2020
PDF 1.08 MB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
12/4/2020
PDF 1.09 MB
Technical Note 163_Addressing PID Instruments Moisture Sensitivity
944.51 KB
12/4/2020
PDF 944.51 KB
Technical Note 165_Combating Drift In Portable And Fixed PIDs
930.69 KB
12/4/2020
PDF 930.69 KB
Technical Note 156_Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
12/4/2020
PDF 609.21 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
12/4/2020
PDF 950.72 KB
Technical Note 146_Turning On UV Lamps In A PID Monitor
787.55 KB
12/4/2020
PDF 787.55 KB
Technical Note 121_CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
12/4/2020
PDF 785.04 KB
Technical Note 144_Handling LEL Sensor Poisons
802.28 KB
12/4/2020
PDF 802.28 KB
Technical Note 130_Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Technical-Note-114_updated_03-26-2018.pdf
795.02 KB
12/4/2020
PDF 795.02 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 205_Measuring Heat Transfer Fluids With A PID
831.7 KB
12/4/2020
PDF 831.7 KB
Application Note 000_RAE Systems PID Training Outline
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 201_Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 228_Facility And Venue Protection
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 216_Using PIDs In Terrorist Chemical Attacks_04-01
1.07 MB
12/4/2020
PDF 1.07 MB
Application Note 211_PIDs For Continuous Monitoring Of VOCs
826.34 KB
12/4/2020
PDF 826.34 KB
Application Note 203_PIDs As HazMat Response Tools
1.26 MB
12/4/2020
PDF 1.26 MB
Application Note 215_Gas Detection In The Marine Industries
889.61 KB
12/4/2020
PDF 889.61 KB
Application Note 221_Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
12/4/2020
PDF 964.88 KB
Application Note 235_Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
12/4/2020
PDF 750.69 KB
White Paper
Name
Description
File Size
Date
Size
Application Note 204_Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
12/4/2020
PDF 949.42 KB
Data Sheet
Name
Description
File Size
Date
Size
Brochure
Name
Description
File Size
Date
Size
Others
Name
Description
File Size
Date
Size
Techninal Note 123_Special Diagnostic Modes For RAE Systems Instruments_10-05
899.77 KB
12/4/2020
PDF 899.77 KB
Product Notice 2017053B _SAFETY ADVISORY
125.12 KB
12/4/2020
PDF 125.12 KB
AreaRAE Plus & AreaRAE Pro User's Guide
5.65 MB
12/4/2020
PDF 5.65 MB
Name
Description
File Size
Date
Size
Technical-Note-182 Basics of Wireless Security
1.01 MB
12/4/2020
PDF 1.01 MB
Techninal Note 123_Special Diagnostic Modes For RAE Systems Instruments_10-05
899.77 KB
12/4/2020
PDF 899.77 KB
Technical-Note-106_A-Guideline-for-Pid-Instrument-Response.pdf
1.45 MB
12/4/2020
PDF 1.45 MB
Technical-Note 148_Defining-The-Interval-Between-Calibration-Checks_12-15.pdf
839.32 KB
12/4/2020
PDF 839.32 KB
Technical Note 174_Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
12/4/2020
PDF 814.89 KB
Technical Note 159_Chemical Warfare Agent Measurements By PID
884.91 KB
12/4/2020
PDF 884.91 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
12/4/2020
PDF 884.37 KB
Product Notice 2017053B _SAFETY ADVISORY
125.12 KB
12/4/2020
PDF 125.12 KB
Technical Note 167_Proper Use Of Dilution Fittings On Pumped Monitors
1.02 MB
12/4/2020
PDF 1.02 MB
Technical Note 152_Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
12/4/2020
PDF 839.29 KB
Technical Note 157_Moisture Exchange Tubes For Humidity Control Of Test Gases
1.08 MB
12/4/2020
PDF 1.08 MB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
12/4/2020
PDF 1.09 MB
Technical Note 163_Addressing PID Instruments Moisture Sensitivity
944.51 KB
12/4/2020
PDF 944.51 KB
Technical Note 165_Combating Drift In Portable And Fixed PIDs
930.69 KB
12/4/2020
PDF 930.69 KB
Technical Note 156_Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
12/4/2020
PDF 609.21 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
12/4/2020
PDF 950.72 KB
Technical Note 146_Turning On UV Lamps In A PID Monitor
787.55 KB
12/4/2020
PDF 787.55 KB
Technical Note 121_CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
12/4/2020
PDF 785.04 KB
Technical Note 144_Handling LEL Sensor Poisons
802.28 KB
12/4/2020
PDF 802.28 KB
Technical Note 130_Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Application Note 205_Measuring Heat Transfer Fluids With A PID
831.7 KB
12/4/2020
PDF 831.7 KB
Application Note 000_RAE Systems PID Training Outline
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 201_Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 204_Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
12/4/2020
PDF 949.42 KB
Application Note 228_Facility And Venue Protection
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 216_Using PIDs In Terrorist Chemical Attacks_04-01
1.07 MB
12/4/2020
PDF 1.07 MB
Application Note 211_PIDs For Continuous Monitoring Of VOCs
826.34 KB
12/4/2020
PDF 826.34 KB
Application Note 203_PIDs As HazMat Response Tools
1.26 MB
12/4/2020
PDF 1.26 MB
Application Note 215_Gas Detection In The Marine Industries
889.61 KB
12/4/2020
PDF 889.61 KB
Application Note 221_Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
12/4/2020
PDF 964.88 KB
Application Note 235_Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
12/4/2020
PDF 750.69 KB
AreaRAE Plus & AreaRAE Pro User's Guide
5.65 MB
12/4/2020
PDF 5.65 MB
Technical-Note-114_updated_03-26-2018.pdf
795.02 KB
12/4/2020
PDF 795.02 KB