The AreaRAE Plus provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to configure device. Plus, you’ll have vital details about threats happening in real-time—arming you with the information you need to act quickly.

Features and Benefits:

  • Monitors up to seven threats, including VOCs, combustibles, Toxics and Oxygen
  • Optional meteorological sensor for tracking toxic plumes
  • 7R+ photoionization detector (PID) for monitoring VOCs at parts per million
  • Secondary radio module (Mesh) act as an communication Hub for other wireless devices
  • Ruggedized, portable, and weather-resistant design for harsh environments
  • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations

Application:

  • Confined Space Entry
  • Environmental Cleanups/ Remediation
  • Fence Line Monitoring
  • Leak Detection
  • Plant Shutdown & Turn-Around
Xарактеристики

Brand

  • Brand
    • RAE

Sampling

  • Sampling Pump Range
    • 100ft (30m)

Dimensions

  • Weight
    • 14.33 US Pound
    • 6.5 kilogram

Category

  • Sub-Category
    • Transportable

Dimension & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Range

  • Humidity Range
    • 0%-95% percent
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
    • VOC (0-2000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)- NH3 (0-100ppm)- CO (0-2000ppm)- Cl2 (0-50ppm)- ETO (0-500ppm)- H2 (0-2000ppm)- HCL (0-15ppm)- HCN (0-50ppm)- HF (0.5-10ppm)- H2S (0-1000ppm)- O2 (0-30%)- SO2 (0-20ppm)- NO (0-250ppm)- NO2 (0-20ppm)- PH3 (0-20ppm)

Alarm

  • Alarm Type
    • Visual, Audible, Vibrating
    • Visual- Audible- Vibrating

Battery & Charging

  • Battery Run Time
    • 20 hours
    • 20 Hours hours

Certifications

  • Standards
    • US / Canada: Class 1, Division 2 Groups A, B, C, D
    • US / Canada: Class 1- Division 2 Groups A- B- C- D

Datalogging

  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
    • Continuous data logging (90 days for 7 gas sensors- 1 Gamma

Features & Benefits

  • Benefits
    • • Delivers real-time readings to Honeywell’s

Options

  • User Options
    • 3 operation and programming keys

Warranty

  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Wireless

  • Wireless Technology
    • BLE, MESH, WiFi
    • BLE- MESH- WiFi

Additional Specifications

  • Ingress Protection
    • IP65
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
    • VOC- LEL- CO2- NH3- CO- Cl2- ETO- H2- HCL- HCN- HF- H2S- O2- SO2- NO- NO2- PH3

Others

  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 140 degree Fahrenheit
    • 60 degree Celsius

Brand

  • Brand
    • RAE

Sampling

  • Sampling Pump Range
    • 100ft (30m)

Dimensions

  • Weight
    • 14.33 US Pound
    • 6.5 kilogram

Category

  • Sub-Category
    • Transportable

Dimension & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Range

  • Humidity Range
    • 0%-95% percent
  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
    • VOC (0-2000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)- NH3 (0-100ppm)- CO (0-2000ppm)- Cl2 (0-50ppm)- ETO (0-500ppm)- H2 (0-2000ppm)- HCL (0-15ppm)- HCN (0-50ppm)- HF (0.5-10ppm)- H2S (0-1000ppm)- O2 (0-30%)- SO2 (0-20ppm)- NO (0-250ppm)- NO2 (0-20ppm)- PH3 (0-20ppm)

Alarm

  • Alarm Type
    • Visual, Audible, Vibrating
    • Visual- Audible- Vibrating

Battery & Charging

  • Battery Run Time
    • 20 hours
    • 20 Hours hours

Certifications

  • Standards
    • US / Canada: Class 1, Division 2 Groups A, B, C, D
    • US / Canada: Class 1- Division 2 Groups A- B- C- D

Datalogging

  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
    • Continuous data logging (90 days for 7 gas sensors- 1 Gamma

Features & Benefits

  • Benefits
    • • Delivers real-time readings to Honeywell’s

Options

  • User Options
    • 3 operation and programming keys

Warranty

  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Wireless

  • Wireless Technology
    • BLE, MESH, WiFi
    • BLE- MESH- WiFi

Additional Specifications

  • Ingress Protection
    • IP65
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
    • VOC- LEL- CO2- NH3- CO- Cl2- ETO- H2- HCL- HCN- HF- H2S- O2- SO2- NO- NO2- PH3

Others

  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 140 degree Fahrenheit
    • 60 degree Celsius
  • Brand : RAE
  • Sampling Pump Range : 100ft (30m)
  • Weight : 14.33 US Pound|6.5 kilogram
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Maximum Temperature : 140 degree Fahrenheit|60 degree Celsius
  • Sub-Category : Transportable
  • Instrument Size : 12.36” x 12.04” x 6.53”
  • Humidity Range : 0%-95% percent
  • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)|VOC (0-2000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)- NH3 (0-100ppm)- CO (0-2000ppm)- Cl2 (0-50ppm)- ETO (0-500ppm)- H2 (0-2000ppm)- HCL (0-15ppm)- HCN (0-50ppm)- HF (0.5-10ppm)- H2S (0-1000ppm)- O2 (0-30%)- SO2 (0-20ppm)- NO (0-250ppm)- NO2 (0-20ppm)- PH3 (0-20ppm)
  • Alarm Type : Visual, Audible, Vibrating|Visual- Audible- Vibrating
  • Battery Run Time : 20 hours|20 Hours hours
  • Standards : US / Canada: Class 1, Division 2 Groups A, B, C, D|US / Canada: Class 1- Division 2 Groups A- B- C- D
  • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma|Continuous data logging (90 days for 7 gas sensors- 1 Gamma
  • Benefits : • Delivers real-time readings to Honeywell’s
  • User Options : 3 operation and programming keys
  • Warranty : Four years for O2 Liquid Oxygen sensors
  • Wireless Technology : BLE, MESH, WiFi|BLE- MESH- WiFi
  • Ingress Protection : IP65
  • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3|VOC- LEL- CO2- NH3- CO- Cl2- ETO- H2- HCL- HCN- HF- H2S- O2- SO2- NO- NO2- PH3
Технические характеристики
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
application/pdf 569.87 KB
11/3/2021
569.87 KB
Руководства и инструкции
Name
Description
File Size
Date
Size
AreaRAE Plus & AreaRAE Pro User's Guide
application/pdf 5.65 MB
11/3/2021
5.65 MB
AreaRAE Pro and Plus - Quick start guide
application/pdf 689.87 KB
11/3/2021
689.87 KB
Микропрограммное обеспечение
Name
Description
File Size
Date
Size
Area RAE 1.12 Firmware and Release Notes
application/zip 2.01 MB
8/18/2023
2.01 MB
AREARAE Plus / Pro v 1.08
application/zip 1.57 MB
11/3/2021
1.57 MB
Брошюра
Name
Description
File Size
Date
Size
AreaRAE Plus Brochure
application/pdf 3.23 MB
11/3/2021
3.23 MB
Техническое примечание
Name
Description
File Size
Date
Size
AreaRAE PlusPro Technical Note 106A
application/pdf 428.08 KB
11/3/2021
428.08 KB
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
application/pdf 146.2 KB
8/10/2022
146.2 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
11/3/2021
950.72 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
11/3/2021
1.08 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
11/3/2021
125.12 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
11/1/2022
1.45 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
11/3/2021
884.37 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
11/3/2021
911.54 KB
Technical Note 144 Handling LEL Sensor Poisons
application/pdf 802.28 KB
8/3/2022
802.28 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
application/pdf 1.02 MB
11/3/2021
1.02 MB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
11/3/2021
944.51 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
11/3/2021
788.83 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
11/3/2021
609.21 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
11/3/2021
795.02 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
8/3/2022
820.7 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
11/3/2021
930.69 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
11/3/2021
884.91 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
11/3/2021
814.89 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
11/3/2021
787.55 KB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
11/3/2021
1.01 MB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
11/3/2021
1.09 MB
Информационный обзор
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
11/3/2021
949.42 KB
Сертификат
Name
Description
File Size
Date
Size
AreaRAE Plus and Pro - Certificate of compliance
application/pdf 45.13 KB
11/3/2021
45.13 KB
Указания по применению
Name
Description
File Size
Date
Size
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
11/3/2021
826.34 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
11/3/2021
964.88 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
11/3/2021
1.26 MB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
11/3/2021
831.7 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
11/3/2021
1.1 MB
Application Note 228 - Facility and Venue Protection
application/pdf 1.1 MB
11/3/2021
1.1 MB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
11/3/2021
1.07 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
11/3/2021
655.59 KB
Application Note 215: Gas Detection In The Marine Industries
application/pdf 889.61 KB
11/3/2021
889.61 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 750.69 KB
11/3/2021
750.69 KB
Name
Description
File Size
Date
Size
AreaRAE PlusPro Technical Note 106A
application/pdf 428.08 KB
11/3/2021
428.08 KB
Area RAE 1.12 Firmware and Release Notes
application/zip 2.01 MB
8/18/2023
2.01 MB
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
application/pdf 146.2 KB
8/10/2022
146.2 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
11/3/2021
826.34 KB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
11/3/2021
949.42 KB
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
11/3/2021
950.72 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
11/3/2021
1.08 MB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
11/3/2021
964.88 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
11/3/2021
1.26 MB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
11/3/2021
831.7 KB
AreaRAE Plus & AreaRAE Pro User's Guide
application/pdf 5.65 MB
11/3/2021
5.65 MB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
11/3/2021
1.1 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
11/3/2021
125.12 KB
AREARAE Plus / Pro v 1.08
application/zip 1.57 MB
11/3/2021
1.57 MB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
11/1/2022
1.45 MB
Application Note 228 - Facility and Venue Protection
application/pdf 1.1 MB
11/3/2021
1.1 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
11/3/2021
884.37 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
11/3/2021
911.54 KB
Technical Note 144 Handling LEL Sensor Poisons
application/pdf 802.28 KB
8/3/2022
802.28 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
application/pdf 1.02 MB
11/3/2021
1.02 MB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
11/3/2021
944.51 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
11/3/2021
788.83 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
11/3/2021
609.21 KB
AreaRAE Plus and Pro - Certificate of compliance
application/pdf 45.13 KB
11/3/2021
45.13 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
11/3/2021
795.02 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
8/3/2022
820.7 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
11/3/2021
1.07 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
11/3/2021
655.59 KB
Application Note 215: Gas Detection In The Marine Industries
application/pdf 889.61 KB
11/3/2021
889.61 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
11/3/2021
930.69 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
AreaRAE Plus Brochure
application/pdf 3.23 MB
11/3/2021
3.23 MB
AreaRAE Plus Datasheet
application/pdf 569.87 KB
11/3/2021
569.87 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
11/3/2021
884.91 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
11/3/2021
814.89 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
11/3/2021
787.55 KB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
11/3/2021
1.01 MB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
11/3/2021
1.09 MB
Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 750.69 KB
11/3/2021
750.69 KB
AreaRAE Pro and Plus - Quick start guide
application/pdf 689.87 KB
11/3/2021
689.87 KB
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
569.87 KB
11/3/2021
AreaRAE Plus & AreaRAE Pro User's Guide
5.65 MB
11/3/2021
AreaRAE Pro and Plus - Quick start guide
689.87 KB
11/3/2021
Area RAE 1.12 Firmware and Release Notes
2.01 MB
8/18/2023
AREARAE Plus / Pro v 1.08
1.57 MB
11/3/2021
AreaRAE Plus Brochure
3.23 MB
11/3/2021
AreaRAE PlusPro Technical Note 106A
428.08 KB
11/3/2021
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
146.2 KB
8/10/2022
Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
950.72 KB
11/3/2021
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
11/3/2021
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
11/3/2021
A Guideline for Pid Instrument Response
1.45 MB
11/1/2022
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
11/3/2021
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
11/3/2021
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
8/3/2022
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
1.02 MB
11/3/2021
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
11/3/2021
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
11/3/2021
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
11/3/2021
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
11/3/2021
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
8/3/2022
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
8/3/2022
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
11/1/2022
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
11/3/2021
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
8/3/2022
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
11/3/2021
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
11/3/2021
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
11/3/2021
Technical Note 182 Basics of Wireless Security
1.01 MB
11/3/2021
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
1.09 MB
11/3/2021
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
11/3/2021
AreaRAE Plus and Pro - Certificate of compliance
45.13 KB
11/3/2021
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
11/3/2021
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
11/3/2021
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
11/3/2021
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
11/3/2021
Application Note 000: RAE Systems PID Overview
1.1 MB
11/3/2021
Application Note 228 - Facility and Venue Protection
1.1 MB
11/3/2021
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
11/3/2021
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
11/3/2021
Application Note 215: Gas Detection In The Marine Industries
889.61 KB
11/3/2021
Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
11/3/2021