/content/sps/ru/ru/search-results.html

Portables

MultiRAE Lite Pumped

Wireless, portable multi-gas monitor

Обзор продукта

This multi-gas monitor provides versatile, customizable detection and monitoring of up to six gases, available in both pumped and diffused air models. With more than 25 sensors to choose from — the broadest selection in its class — it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a range of industries and applications. The wireless connection sends threat and alarm data in real time to a central command, providing superior awareness for fast incident response. And its replaceable sensors, alarm, and battery, large screen, and automated bump testing and calibration make it easy to use and maintain.

Features and Benefits:

  • Multi-gas monitor for 1-6 gases
  • Pumped and diffusion models available
  • Man down alarm
  • More than 25 different chemical sensors
  • Fully automatic bump testing and calibration
  • Real-time access to readings at central command
  • Swap out sensors as needed
  • Simple maintenance with replaceable sensors, pump, and battery
  • 5-way local and remote wireless alarm
  • Multi-language capability – up to 18 languages
  • Device Management with Honeywell Sotera™ Express
  • Readily enables to communicate with Motorola MOTOTRBO

Application:

  • Clandestine Labs
  • Confined Space Entry
  • Emergency Response
  • Environmental Cleanups/ Remediation
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Urban Search & Rescue
Xарактеристики

Brand

  • Brand
    • RAE

Dimensions

  • Weight
    • 31
    • 880 gram

Category

  • Sub-Category
    • Multi-Gas

Dimension & Weight

  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Range

  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
    • NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
  • Humidity Range
    • 0%-95% percent

Alarm

  • Alarm Type
    • Audible, Visual, Vibrating
    • Audible- Visual- Vibrating

Battery & Charging

  • Battery Run Time
    • 12-18 hours

Certifications

  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
    • CSA: Class I- Division 1- Groups A- B- C- and D- T4

Datalogging

  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)

Features & Benefits

  • Benefits
    • Highly versatile and customizable

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • 3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected

Sampling

  • Sampling Pump Range
    • 100ft (30m) meter

Warranty

  • Warranty
    • Four years on Liq O2 sensors

Wireless

  • Wireless Technology
    • BLE

Additional Specifications

  • Ingress Protection
    • IP65
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
    • NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2

Others

  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50 degree Celsius
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit

Brand

  • Brand
    • RAE

Dimensions

  • Weight
    • 31
    • 880 gram

Category

  • Sub-Category
    • Multi-Gas

Dimension & Weight

  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Range

  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
    • NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
  • Humidity Range
    • 0%-95% percent

Alarm

  • Alarm Type
    • Audible, Visual, Vibrating
    • Audible- Visual- Vibrating

Battery & Charging

  • Battery Run Time
    • 12-18 hours

Certifications

  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
    • CSA: Class I- Division 1- Groups A- B- C- and D- T4

Datalogging

  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)

Features & Benefits

  • Benefits
    • Highly versatile and customizable

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • 3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected

Sampling

  • Sampling Pump Range
    • 100ft (30m) meter

Warranty

  • Warranty
    • Four years on Liq O2 sensors

Wireless

  • Wireless Technology
    • BLE

Additional Specifications

  • Ingress Protection
    • IP65
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
    • NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2

Others

  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50 degree Celsius
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Brand : RAE
  • Maximum Temperature : 122 degree Fahrenheit|50 degree Celsius
  • Weight : 31|880 gram
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Sub-Category : Multi-Gas
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)|NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
  • Humidity Range : 0%-95% percent
  • Alarm Type : Audible, Visual, Vibrating|Audible- Visual- Vibrating
  • Battery Run Time : 12-18 hours
  • Standards : CSA: Class I, Division 1, Groups A, B, C, and D, T4|CSA: Class I- Division 1- Groups A- B- C- and D- T4
  • Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)|Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)
  • Benefits : Highly versatile and customizable
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected|3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected
  • Sampling Pump Range : 100ft (30m) meter
  • Warranty : Four years on Liq O2 sensors
  • Wireless Technology : BLE
  • Ingress Protection : IP65
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2|NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2
Технические характеристики
Name
Description
File Size
Date
Size
MultiRAE Lite Diffused & Pumped Data Sheet
application/pdf 137.81 KB
11/3/2021
137.81 KB
Руководства и инструкции
Name
Description
File Size
Date
Size
MultiRAE - User Guide - Russian
application/pdf 13.84 MB
4/11/2023
13.84 MB
MultiRAE (Pumped) QuickStart Guide
application/pdf 302.5 KB
11/3/2021
302.5 KB
Брошюра
Name
Description
File Size
Date
Size
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
11/3/2021
441.3 KB
Техническое примечание
Name
Description
File Size
Date
Size
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
11/3/2021
609.21 KB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
11/3/2021
620.4 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 750.26 KB
11/1/2022
750.26 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
11/1/2022
1.45 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
11/1/2022
820.7 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
Technical Note 141 Monitor Remote Control Functions
application/pdf 984.3 KB
8/3/2022
984.3 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
11/3/2021
125.12 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
11/3/2021
788.83 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
11/3/2021
795.02 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
11/3/2021
911.54 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
application/pdf 976.3 KB
11/3/2021
976.3 KB
Сертификат
Name
Description
File Size
Date
Size
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
MultiRAE Lite - IECEx Certificate of Conformity
application/pdf 155.39 KB
3/14/2023
155.39 KB
Указания по применению
Name
Description
File Size
Date
Size
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
application/pdf 1 MB
11/3/2021
1 MB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
11/3/2021
1.1 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
Application 202: The ABC®s Of Gases In The Industry
application/pdf 843.47 KB
11/3/2021
843.47 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
11/3/2021
901.23 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
11/3/2021
655.59 KB
Name
Description
File Size
Date
Size
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
11/3/2021
609.21 KB
MultiRAE - INMETRO Certificate of Conformity
472.03 KB
4/24/2023
472.03 KB
MultiRAE - User Guide - Russian
13.84 MB
4/11/2023
13.84 MB
MultiRAE Lite - IECEx Certificate of Conformity
155.39 KB
3/14/2023
155.39 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
11/3/2021
1 MB
MultiRAE Series Technical Note 106B
620.4 KB
11/3/2021
620.4 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
8/3/2022
994.45 KB
MultiRAE (Pumped) QuickStart Guide
302.5 KB
11/3/2021
302.5 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
11/3/2021
1.1 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
941.33 KB
8/4/2022
941.33 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
8/3/2022
839.29 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
11/1/2022
750.26 KB
A Guideline for Pid Instrument Response
1.45 MB
11/1/2022
1.45 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
11/1/2022
820.7 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
11/1/2022
785.04 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
8/3/2022
984.3 KB
Application 202: The ABC®s Of Gases In The Industry
843.47 KB
11/3/2021
843.47 KB
MultiRAE Lite Diffused & Pumped Data Sheet
137.81 KB
11/3/2021
137.81 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
11/3/2021
901.23 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
11/3/2021
125.12 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
11/3/2021
788.83 KB
MSI-Honeywell Connected Safety Solution
441.3 KB
11/3/2021
441.3 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
11/3/2021
655.59 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
11/3/2021
795.02 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
11/3/2021
911.54 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
976.3 KB
11/3/2021
976.3 KB
Name
Description
File Size
Date
Size
MultiRAE Lite Diffused & Pumped Data Sheet
137.81 KB
11/3/2021
MultiRAE - User Guide - Russian
13.84 MB
4/11/2023
MultiRAE (Pumped) QuickStart Guide
302.5 KB
11/3/2021
MSI-Honeywell Connected Safety Solution
441.3 KB
11/3/2021
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
11/3/2021
MultiRAE Series Technical Note 106B
620.4 KB
11/3/2021
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
8/3/2022
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
8/3/2022
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
11/1/2022
A Guideline for Pid Instrument Response
1.45 MB
11/1/2022
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
11/1/2022
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
11/1/2022
Technical Note 141 Monitor Remote Control Functions
984.3 KB
8/3/2022
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
11/3/2021
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
11/3/2021
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
11/3/2021
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
11/3/2021
Electrochemical Sensor Replacement & Maintenance Technical Note 151
976.3 KB
11/3/2021
MultiRAE - INMETRO Certificate of Conformity
472.03 KB
4/24/2023
MultiRAE Lite - IECEx Certificate of Conformity
155.39 KB
3/14/2023
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
11/3/2021
Application Note 000: RAE Systems PID Overview
1.1 MB
11/3/2021
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
941.33 KB
8/4/2022
Application 202: The ABC®s Of Gases In The Industry
843.47 KB
11/3/2021
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
11/3/2021
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
11/3/2021
Product Number
Image
SKU
Description
alt
MAA3-0000000-320
MR LT/ATX/PMP/ 868M
alt
MAA3-0000001-P20
alt
MAA3-0000002-020
alt
MAA3-0000004-020
alt
MAA3-0000006-020
alt
MAA3-0000008-020
газоанализатор MRAE LITE NH3
alt
MAA3-000000A-020
alt
MAA3-000000E-020
газоанализатор MultiRAE LITE
alt
MAA3-000000E-021
alt
MAA3-000000E-030
Image
SKU
Description
alt
MAA3-0000000-320
MR LT/ATX/PMP/ 868M
alt
MAA3-0000001-P20
alt
MAA3-0000002-020
alt
MAA3-0000004-020
alt
MAA3-0000006-020
alt
MAA3-0000008-020
газоанализатор MRAE LITE NH3
alt
MAA3-000000A-020
alt
MAA3-000000E-020
газоанализатор MultiRAE LITE
alt
MAA3-000000E-021
alt
MAA3-000000E-030