Поиск на sps.honeywell.com

/content/sps/ru/ru/search-results.html

Portables

ToxiRAE Pro PID

Compact, wireless VOC single gas monitor

Protect workers from the threat of volatile organic compounds (VOCs) in the workplace and observe conditions remotely from a central command station with this compact, wireless monitor. The ToxiRAE Pro PID’s next-generation sensor can detect over 300 VOCs and uses a built-in on-board library of 190 correction factors to automatically read gases in equivalent units. Reliable, rugged, and intrinsically safe, the ToxiRAE Pro PID can be easily attached to workers’ uniforms, and also provides a man-down alarm. It all adds up to better visibility and faster incident response in a variety of conditions.

Features and Benefits:

  • Compact, personal wireless monitor
  • PID sensor accurately monitors over 300 VOCs
  • Built-in library of 190 correction factors for automatic reading in equivalent units
  • 5-way local and remote wireless alarm
  • Water-, dust-, and shock-resistant
  • Built-in man down alarm
  • Fully automatic bump testing and calibration with AutoRAE2
  • Readily enables to communicate with Motorola MOTOTRBO

Application:

  • Environmental Cleanups/ Remediation
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Worker Exposure

Dimension & Weight

  • Weight
    • 235 gram
    • 8.29

Temperature

  • Maximum Temperature
    • 55 degree Celsius
    • 131 degree Fahrenheit
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit

Others

  • Brand
    • RAE
  • Sub-Category
    • Single-Gas
  • Instrument Size
    • 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
  • Sensor Range
    • VOC (0-2000ppm)
  • Humidity Range
    • 0%-95%
  • Alarm Type
    • Audible- Visual- Vibrating
    • Audible, Visual, Vibrating
  • Battery Run Time
    • 12
    • 12hours
  • Standards
    • CSA: Class I- Division 1- Groups A- B- C and D. T-code T4 Class I-
    • CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I,
  • Datalogging
    • Three-month capacity
  • Benefits
    • • Wireless elevates safety to the next level
  • User Options
    • - Wireless remote alarm notification; audible (95 dB @ 30 cm)-
    • - Wireless remote alarm notification; audible (95 dB @ 30 cm),
  • Wireless Technology
    • MESH
  • Warranty
    • Four years on O2 sensor
  • Gas Type
    • VOC
  • Ingress Protection
    • IP65

Dimension & Weight

  • Weight
    • 235 gram
    • 8.29

Temperature

  • Maximum Temperature
    • 55 degree Celsius
    • 131 degree Fahrenheit
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit

Others

  • Brand
    • RAE
  • Sub-Category
    • Single-Gas
  • Instrument Size
    • 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
  • Sensor Range
    • VOC (0-2000ppm)
  • Humidity Range
    • 0%-95%
  • Alarm Type
    • Audible- Visual- Vibrating
    • Audible, Visual, Vibrating
  • Battery Run Time
    • 12
    • 12hours
  • Standards
    • CSA: Class I- Division 1- Groups A- B- C and D. T-code T4 Class I-
    • CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I,
  • Datalogging
    • Three-month capacity
  • Benefits
    • • Wireless elevates safety to the next level
  • User Options
    • - Wireless remote alarm notification; audible (95 dB @ 30 cm)-
    • - Wireless remote alarm notification; audible (95 dB @ 30 cm),
  • Wireless Technology
    • MESH
  • Warranty
    • Four years on O2 sensor
  • Gas Type
    • VOC
  • Ingress Protection
    • IP65
  • Brand : RAE
  • Sub-Category : Single-Gas
  • Instrument Size : 4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm)
  • Sensor Range : VOC (0-2000ppm)
  • Humidity Range : 0%-95%
  • Alarm Type : Audible- Visual- Vibrating|Audible, Visual, Vibrating
  • Battery Run Time : 12|12hours
  • Standards : CSA: Class I- Division 1- Groups A- B- C and D. T-code T4 Class I-|CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I,
  • Datalogging : Three-month capacity
  • Benefits : • Wireless elevates safety to the next level
  • User Options : - Wireless remote alarm notification; audible (95 dB @ 30 cm)-|- Wireless remote alarm notification; audible (95 dB @ 30 cm),
  • Wireless Technology : MESH
  • Warranty : Four years on O2 sensor
  • Gas Type : VOC
  • Ingress Protection : IP65
  • Weight : 235 gram|8.29
  • Maximum Temperature : 55 degree Celsius|131 degree Fahrenheit
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
Технические характеристики
Name
Description
File Size
Date
Size
ToxiRAE 3 Data Sheet - EN
application/pdf 104.8 KB
11/3/2021
104.8 KB
Руководства и инструкции
Name
Description
File Size
Date
Size
ToxiRAE Pro PID Manual Rev D
application/pdf 3.31 MB
11/3/2021
3.31 MB
ToxiRAE Pro PID QuickStart Guide Rev D
application/pdf 335.53 KB
11/3/2021
335.53 KB
ToxiRAE Pro PID User Guide
application/pdf 2.57 MB
11/3/2021
2.57 MB
Микропрограммное обеспечение
Name
Description
File Size
Date
Size
ToxiRAE Pro PID V1.84C
application/zip 411.83 KB
11/3/2021
411.83 KB
Брошюра
Name
Description
File Size
Date
Size
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
11/3/2021
441.3 KB
Техническое примечание
Name
Description
File Size
Date
Size
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
11/3/2021
1.08 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
8/3/2022
820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
11/3/2021
788.83 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
11/3/2021
795.02 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
11/3/2021
884.37 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
11/3/2021
944.51 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 750.26 KB
8/3/2022
750.26 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
11/3/2021
930.69 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
11/3/2021
787.55 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
11/3/2021
884.91 KB
ToxiRAE Pro PID Technical Note 106E
application/pdf 429.98 KB
11/3/2021
429.98 KB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
11/3/2021
1.01 MB
Информационный обзор
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
11/3/2021
949.42 KB
Указания по применению
Name
Description
File Size
Date
Size
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
11/3/2021
901.23 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 750.69 KB
11/3/2021
750.69 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
11/3/2021
831.7 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
11/3/2021
655.59 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
11/3/2021
1.26 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
11/3/2021
826.34 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
11/3/2021
964.88 KB
Application Note 212 Using PIDs For Indoor Air Quality (IAQ) Surveys
application/pdf 1.1 MB
11/3/2021
1.1 MB
Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 729.36 KB
11/3/2021
729.36 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
11/3/2021
1.1 MB
Name
Description
File Size
Date
Size
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
11/3/2021
901.23 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
11/3/2021
1.08 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
8/3/2022
820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
11/3/2021
788.83 KB
Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
11/3/2021
750.69 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
11/3/2021
831.7 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
11/3/2021
655.59 KB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
11/3/2021
1.26 MB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
11/3/2021
949.42 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
11/3/2021
795.02 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
11/3/2021
826.34 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
11/3/2021
964.88 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
11/3/2021
884.37 KB
ToxiRAE Pro PID Manual Rev D
3.31 MB
11/3/2021
3.31 MB
ToxiRAE 3 Data Sheet - EN
104.8 KB
11/3/2021
104.8 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
11/3/2021
944.51 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
8/3/2022
750.26 KB
Application Note 212 Using PIDs For Indoor Air Quality (IAQ) Surveys
1.1 MB
11/3/2021
1.1 MB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
11/3/2021
930.69 KB
A Guideline for Pid Instrument Response
1.45 MB
8/3/2022
1.45 MB
ToxiRAE Pro PID QuickStart Guide Rev D
335.53 KB
11/3/2021
335.53 KB
ToxiRAE Pro PID User Guide
2.57 MB
11/3/2021
2.57 MB
MSI-Honeywell Connected Safety Solution
441.3 KB
11/3/2021
441.3 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
11/3/2021
787.55 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
11/3/2021
884.91 KB
Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
729.36 KB
11/3/2021
729.36 KB
ToxiRAE Pro PID Technical Note 106E
429.98 KB
11/3/2021
429.98 KB
ToxiRAE Pro PID V1.84C
411.83 KB
11/3/2021
411.83 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
11/3/2021
1.1 MB
Technical Note 182 Basics of Wireless Security
1.01 MB
11/3/2021
1.01 MB
Name
Description
File Size
Date
Size
ToxiRAE 3 Data Sheet - EN
104.8 KB
11/3/2021
ToxiRAE Pro PID Manual Rev D
3.31 MB
11/3/2021
ToxiRAE Pro PID QuickStart Guide Rev D
335.53 KB
11/3/2021
ToxiRAE Pro PID User Guide
2.57 MB
11/3/2021
ToxiRAE Pro PID V1.84C
411.83 KB
11/3/2021
MSI-Honeywell Connected Safety Solution
441.3 KB
11/3/2021
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
1.08 MB
11/3/2021
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
8/3/2022
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
11/3/2021
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
11/3/2021
Technical Note 161 Intrinsic Safety And Hazardous Locations
884.37 KB
11/3/2021
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
944.51 KB
11/3/2021
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
8/3/2022
Technical Note 165 Combating Drift In Portable And Fixed PIDs
930.69 KB
11/3/2021
A Guideline for Pid Instrument Response
1.45 MB
8/3/2022
Technical Note 146 Turning On UV Lamps In A PID Monitor
787.55 KB
11/3/2021
Technical Note 159 Chemical Warfare Agent Measurements By PID
884.91 KB
11/3/2021
ToxiRAE Pro PID Technical Note 106E
429.98 KB
11/3/2021
Technical Note 182 Basics of Wireless Security
1.01 MB
11/3/2021
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
949.42 KB
11/3/2021
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
11/3/2021
Measurement Of PGMEA Using Photoionization Detectors_12-11
750.69 KB
11/3/2021
Application Note 205 - Measuring Heat Transfer Fluids With A PID
831.7 KB
11/3/2021
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
11/3/2021
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
11/3/2021
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
826.34 KB
11/3/2021
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
11/3/2021
Application Note 212 Using PIDs For Indoor Air Quality (IAQ) Surveys
1.1 MB
11/3/2021
Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
729.36 KB
11/3/2021
Application Note 000: RAE Systems PID Overview
1.1 MB
11/3/2021
Image
SKU
Description
alt
G02-B000-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Non-Wireless
alt
G02-B004-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Wireless (900 MHz)
alt
G02-B010-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) / No Datalogging / Non-Wireless
alt
G02-B014-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) / No Datalogging / Wireless (900 MHz)
alt
G02-B020-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Non-Wireless
alt
G02-B024-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Wireless (900 MHz)
Image
SKU
Description
alt
G02-B000-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Non-Wireless
alt
G02-B004-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Wireless (900 MHz)
alt
G02-B010-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) / No Datalogging / Non-Wireless
alt
G02-B014-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) / No Datalogging / Wireless (900 MHz)
alt
G02-B020-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Non-Wireless
alt
G02-B024-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) / Datalogging / Wireless (900 MHz)