https://sps.honeywell.com/us/en/search-results.html
Outage Notification: On Saturday, June 5,12:30-2:30 p.m. EDT (6:30 to 8:30 p.m. UDT), this website will undergo planned maintenance. Thank you for your patience.

Portables

MultiRAE

Wireless, portable multi-gas monitor with advanced VOC detection

MultiRAE is the most advanced portable chemical detector on the market. With the flexibility of up to six gas sensors and the convenience of wireless portability, this multi-gas monitor is versatile and customizable, while delivering real-time access to instrument readings and alarm status from any location. Choose from 25 sensor options including LEL, PID, NDIR, and exotics that can be easily changed in the field. With five built-in alarms, including man down, and wireless connectivity to your command center, MultiRAE delivers vital information for fast incident response. Features and Benefits: • Optional integrated wireless • 25 field-interchangeable sensor options, including PID, NDIR, and exotics like ammonia, chlorine, and formaldehyde • Five local and remote alarms, including man down • Dust-tight and waterproof (IP65-rated) • Rugged design • Onboard gas libraries include 190 VOCs and 55 combustible gases • Longest battery run-time in its class • Intuitive, icon-driven interface • Flippable screen • Large buttons for easy navigation even with up to three glove layers • Continuous data logging — six months for five sensors 24/7 • Fully automated bump testing and calibration with AutoRAE 2 • Device Management with Honeywell Sotera™ Express Application: • Clandestine Labs • Confined Space Entry • Emergency Response • Environmental Cleanups/ Remediation • Exploration • Fracking • Hazmat Response • Plant Shutdown & Turn-Around • Residential Calls • Urban Search & Rescue • Venue Protection

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Humidity Range
    • 0%-95%
  • Benefits
    • Highly versatile and customizable
  • Sub-Category
    • Premium-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 122 degree Fahrenheit
  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Weight
    • 880 gram
    • 31 ounce av [Invisible]
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • MESH, Wifi, BLE
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time
    • 12-18
  • Warranty
    • Four years on Liq O2 sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Humidity Range
    • 0%-95%
  • Benefits
    • Highly versatile and customizable
  • Sub-Category
    • Premium-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 122 degree Fahrenheit
  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Weight
    • 880 gram
    • 31 ounce av [Invisible]
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • MESH, Wifi, BLE
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time
    • 12-18
  • Warranty
    • Four years on Liq O2 sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Alarm Type : Audible, Visual, Vibrating
  • Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Humidity Range : 0%-95%
  • Benefits : Highly versatile and customizable
  • Sub-Category : Premium-Gas
  • Maximum Temperature : 50 degree Celsius|122 degree Fahrenheit
  • Standards : CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Weight : 880 gram|31 ounce av [Invisible]
  • Sampling Pump Range : 100ft (30m)
  • Brand : RAE
  • Wireless Technology : MESH, Wifi, BLE
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time : 12-18
  • Warranty : Four years on Liq O2 sensors
  • Ingress Protection : IP65
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
Data Sheet
Name
Description
File Size
Date
Size
MultiRAE Data Sheet
124.22 KB
7/15/2021
PDF 124.22 KB
Manuals and Guides
Name
Description
File Size
Date
Size
MultiRAE User's Guide - NL
4.26 MB
7/15/2021
PDF 4.26 MB
MultiRAE User Guide
8.12 MB
7/15/2021
PDF 8.12 MB
MultiRAE User's Guide - ES
4.55 MB
7/15/2021
PDF 4.55 MB
MultiRAE User's Guide - IT
4.64 MB
7/15/2021
PDF 4.64 MB
MultiRAE User's Guide - FR
4.63 MB
7/15/2021
PDF 4.63 MB
MultiRAE User's Guide - RU
5.05 MB
7/15/2021
PDF 5.05 MB
MultiRAE User's Guide - EN
4.54 MB
7/15/2021
PDF 4.54 MB
MultiRAE User's Guide - PT
4.24 MB
7/15/2021
PDF 4.24 MB
MultiRAE (Pumped) QuickStart Guide
302.5 KB
7/15/2021
PDF 302.5 KB
MultiRAE User's Guide - DE
4.56 MB
7/15/2021
PDF 4.56 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
7/15/2021
PDF 839.29 KB
A Guideline for Pid Instrument Response
1.45 MB
7/15/2021
PDF 1.45 MB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
7/15/2021
PDF 609.21 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
976.3 KB
7/15/2021
PDF 976.3 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
7/15/2021
PDF 911.54 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
7/15/2021
PDF 814.89 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
7/15/2021
PDF 750.26 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
7/15/2021
PDF 795.02 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
7/15/2021
PDF 785.04 KB
MultiRAE Series Technical Note 106B
620.4 KB
7/15/2021
PDF 620.4 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
7/15/2021
PDF 820.7 KB
MiniRAE 2000 & MultiRAE Pre-Programmed Compound Libraries_03-06 Technical Note 142
1.05 MB
7/15/2021
PDF 1.05 MB
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
7/15/2021
PDF 994.45 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
PDF 788.83 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
941.33 KB
7/15/2021
PDF 941.33 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
7/15/2021
PDF 125.12 KB
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
7/15/2021
PDF 802.28 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
7/15/2021
PDF 984.3 KB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
7/15/2021
PDF 839.32 KB
Application Note
Name
Description
File Size
Date
Size
Application 202: The ABC®s Of Gases In The Industry
843.47 KB
7/27/2021
PDF 843.47 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
PDF 1.1 MB
Application Note 200: Photoionizatrion Detectors (PIDS) and Aircraft Wing Entry
892.2 KB
8/4/2021
PDF 892.2 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
PDF 655.59 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
7/15/2021
PDF 901.23 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
7/15/2021
PDF 1.07 MB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
226.06 KB
7/15/2021
PDF 226.06 KB
Application Note 207 PIDs As Arson Investigation Tools
857.71 KB
7/15/2021
PDF 857.71 KB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
7/15/2021
PDF 1.26 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
7/15/2021
PDF 1 MB
Name
Description
File Size
Date
Size
MultiRAE User's Guide - NL
4.26 MB
7/15/2021
PDF 4.26 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
7/15/2021
PDF 839.29 KB
Application 202: The ABC®s Of Gases In The Industry
843.47 KB
7/27/2021
PDF 843.47 KB
A Guideline for Pid Instrument Response
1.45 MB
7/15/2021
PDF 1.45 MB
MultiRAE User Guide
8.12 MB
7/15/2021
PDF 8.12 MB
MultiRAE User's Guide - ES
4.55 MB
7/15/2021
PDF 4.55 MB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
7/15/2021
PDF 609.21 KB
Application Note 000: RAE Systems PID Overview
1.1 MB
7/15/2021
PDF 1.1 MB
Application Note 200: Photoionizatrion Detectors (PIDS) and Aircraft Wing Entry
892.2 KB
8/4/2021
PDF 892.2 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
7/15/2021
PDF 655.59 KB
MultiRAE User's Guide - IT
4.64 MB
7/15/2021
PDF 4.64 MB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
976.3 KB
7/15/2021
PDF 976.3 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
7/15/2021
PDF 911.54 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
7/15/2021
PDF 901.23 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
814.89 KB
7/15/2021
PDF 814.89 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
7/15/2021
PDF 750.26 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
7/15/2021
PDF 795.02 KB
MultiRAE User's Guide - FR
4.63 MB
7/15/2021
PDF 4.63 MB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
1.07 MB
7/15/2021
PDF 1.07 MB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
7/15/2021
PDF 785.04 KB
MultiRAE Data Sheet
124.22 KB
7/15/2021
PDF 124.22 KB
MultiRAE User's Guide - RU
5.05 MB
7/15/2021
PDF 5.05 MB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
226.06 KB
7/15/2021
PDF 226.06 KB
MultiRAE User's Guide - EN
4.54 MB
7/15/2021
PDF 4.54 MB
MultiRAE Series Technical Note 106B
620.4 KB
7/15/2021
PDF 620.4 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
7/15/2021
PDF 820.7 KB
Application Note 207 PIDs As Arson Investigation Tools
857.71 KB
7/15/2021
PDF 857.71 KB
MiniRAE 2000 & MultiRAE Pre-Programmed Compound Libraries_03-06 Technical Note 142
1.05 MB
7/15/2021
PDF 1.05 MB
MultiRAE User's Guide - PT
4.24 MB
7/15/2021
PDF 4.24 MB
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
7/15/2021
PDF 994.45 KB
Application Note 203: PIDs As HazMat Response Tools
1.26 MB
7/15/2021
PDF 1.26 MB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
7/15/2021
PDF 788.83 KB
MultiRAE (Pumped) QuickStart Guide
302.5 KB
7/15/2021
PDF 302.5 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
7/15/2021
PDF 1 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
941.33 KB
7/15/2021
PDF 941.33 KB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
7/15/2021
PDF 125.12 KB
Technical Note 144 Handling LEL Sensor Poisons
802.28 KB
7/15/2021
PDF 802.28 KB
MultiRAE User's Guide - DE
4.56 MB
7/15/2021
PDF 4.56 MB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
7/15/2021
PDF 984.3 KB
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
7/15/2021
PDF 839.32 KB
Image
SKU
Description
alt
M01-3214-000
PCB,REAR BUZZER AND LED,DIFF,MULTIRAE LT
alt
M01-3200-000
MultiRAE holster case (pumped models) with shoulder strap
alt
MBA3-A100089-020
MR/ATX/PMP/PID/ NH3/PH3/N-WS
alt
D01-1016-007
PCB ASSY,900MHZ +20DBM WLS MDM RM900A RU
alt
M01-2086-100
Protective rubber boot – red (pumped units; includes two Hex screws)
alt
M01-3055-000
Extended duration Li-ion battery
alt
C03-0962-000
Combustible NDIR sensor (0-100% LEL CH4)
alt
M01-3209-000
Sensor Compartment O-ring pumped, MultiR
alt
MBA3-00C1120-020
MR/ATX/PMP/ LEL/H2S/CO/ N-WS
alt
MBA3-A100008-020
MR/ATX/PMP/PID/ NH3/N-WS