/content/sps/ru/ru/search-results.html

High Tech & Semiconductor

ACM 150 FT-IR Centralized Gas Monitoring System

ACM 150 FT-IR Centralized Gas Monitoring System

Обзор продукта
Multi-point gas detection for enhanced safety and improved performanceProduct Overview:ACM 150 brings you the latest FT-IR technology within a centralized gas monitoring system to offer you many advantages: • Up to 40 measuring points can be centrally located to one device, such as process tools, gas and chemical storage units, gas cabinets, distribution boxes, process tools, emission measurement and ambient air monitoring. • Up to 15 gases can be detected per measuring point, lowering your cost per gas per point monitoring. • Self-diagnostic programming detects faults and critical alarms, eliminating many maintenance calls. • Communications options meet your unique site requirements (Lonworks®, ControlNet™, Modbus®, Profibus®) Improved gas detection performanceThe ACM 150 matches your company’s increased productivity demands with a newly designed FT-IR bench that provides better LDL (Lower Detectable Limit) performance for many gases along with reduced maintenance and service requirements over the life of the instrument.Choose the ACM 150 for enhanced safety, improved performance and lower cost per point monitoring.Additional Features and BenefitsIntegrate gas detection into a single unit • Detect virtually any gas, chemical or odor in an industrial process* • Up to 40 measuring points can be detected sequentially • 80 configurable relay points for increased flexibility Cut monitoring costs over life of device • Sealed aluminum body prevents moisture intrusion, protecting critical internal components • Double IR scan ensures reliable performance, reduces false alarms • Optimized built-in measuring/self diagnostics eliminate on-site gas calibration • Desiccant replacement cycle of 3 to 5 years Boost gas monitoring performance • Composite sampling of up to 4 measuring points provides faster measurement • Easy to service gas cell with stainless steel body construction prevents costly downtime • Better SNR performance allows for lower LDL measurements Simplified touchscreen operation • Superfast processor improves response time • Large user-friendly touchscreen interface • Flexible communications options * Refer to the ACM 150/100 Gas List or ask your regional sales rep for more information. More than two hundred gases detectable. Our engineers may be able to generate a new method for gases not listed.Features & Benefits: • Detects virtually any gas, chemical or odor in an industrial process • Up to 40 measuring points can be sequentially detected • Simplified touchscreen operation Quick Specs: • Analysis method: Continuous scan FT-IR (Fourier Transform Infrared) analyzer • Gas cell path: 5.0 m path length • Scanning rate: ≤ 15 sec per point
Xарактеристики

Brand

  • Brand
    • Honeywell

Category

  • Sub-Category
    • FTIR Analyzer

Features & Benefits

  • Features
    • Возможно последовательное обнаружение в нескольких (до 40) точках измерения
    • Обнаружение практически любых газов, химических веществ или специфических запахов в процессе производства
    • Упрощенная работа с сенсорным экраном

Brand

  • Brand
    • Honeywell

Category

  • Sub-Category
    • FTIR Analyzer

Features & Benefits

  • Features
    • Возможно последовательное обнаружение в нескольких (до 40) точках измерения
    • Обнаружение практически любых газов, химических веществ или специфических запахов в процессе производства
    • Упрощенная работа с сенсорным экраном
  • Brand : Honeywell
  • Sub-Category : FTIR Analyzer
  • Features : Возможно последовательное обнаружение в нескольких (до 40) точках измерения|Обнаружение практически любых газов, химических веществ или специфических запахов в процессе производства|Упрощенная работа с сенсорным экраном
Руководства и инструкции
Name
Description
File Size
Date
Size
ACM 150G2 FT-IR Centralized Gas Monitoring System - User Manual
application/pdf 10.25 MB
5/12/2023
10.25 MB
ACM 150 FT-IR Centralized Gas Monitoring System Installation Guide - EN
application/pdf 6.06 MB
11/3/2021
6.06 MB
Брошюра
Name
Description
File Size
Date
Size
ACM 150 FT-IR Centralized Gas Monitoring System Brochure - EN
application/pdf 4.47 MB
11/3/2021
4.47 MB
Техническое примечание
Name
Description
File Size
Date
Size
Technical Note - IPA, H2S Filter (Molecular Sieve 4A): 1830K0080
application/pdf 155.76 KB
3/20/2023
155.76 KB
ACM 150G2 Webserver Conncection - Technical Note
application/pdf 675.05 KB
11/10/2022
675.05 KB
ACM 150 FT-IR Centralized Gas Monitoring System Spec Sheet - EN
application/pdf 678.8 KB
11/3/2021
678.8 KB
ACM 150 FT-IR Centralized Gas Monitoring System Gas List - EN
application/pdf 321.63 KB
11/3/2021
321.63 KB
Сертификат
Name
Description
File Size
Date
Size
ACM 150 FT-IR Centralized Gas Monitoring System Atex Certificate of Compliance
application/pdf 286.28 KB
11/3/2021
286.28 KB
Name
Description
File Size
Date
Size
ACM 150 FT-IR Centralized Gas Monitoring System Atex Certificate of Compliance
286.28 KB
11/3/2021
286.28 KB
ACM 150G2 FT-IR Centralized Gas Monitoring System - User Manual
10.25 MB
5/12/2023
10.25 MB
Technical Note - IPA, H2S Filter (Molecular Sieve 4A): 1830K0080
155.76 KB
3/20/2023
155.76 KB
ACM 150G2 Webserver Conncection - Technical Note
675.05 KB
11/10/2022
675.05 KB
ACM 150 FT-IR Centralized Gas Monitoring System Brochure - EN
4.47 MB
11/3/2021
4.47 MB
ACM 150 FT-IR Centralized Gas Monitoring System Spec Sheet - EN
678.8 KB
11/3/2021
678.8 KB
ACM 150 FT-IR Centralized Gas Monitoring System Gas List - EN
321.63 KB
11/3/2021
321.63 KB
ACM 150 FT-IR Centralized Gas Monitoring System Installation Guide - EN
6.06 MB
11/3/2021
6.06 MB
Name
Description
File Size
Date
Size
ACM 150G2 FT-IR Centralized Gas Monitoring System - User Manual
10.25 MB
5/12/2023
ACM 150 FT-IR Centralized Gas Monitoring System Installation Guide - EN
6.06 MB
11/3/2021
ACM 150 FT-IR Centralized Gas Monitoring System Brochure - EN
4.47 MB
11/3/2021
Technical Note - IPA, H2S Filter (Molecular Sieve 4A): 1830K0080
155.76 KB
3/20/2023
ACM 150G2 Webserver Conncection - Technical Note
675.05 KB
11/10/2022
ACM 150 FT-IR Centralized Gas Monitoring System Spec Sheet - EN
678.8 KB
11/3/2021
ACM 150 FT-IR Centralized Gas Monitoring System Gas List - EN
321.63 KB
11/3/2021
ACM 150 FT-IR Centralized Gas Monitoring System Atex Certificate of Compliance
286.28 KB
11/3/2021
Product Number
Image
SKU
Description
alt
3014B1212
alt
3014B1213
alt
3014B1214
alt
3014B1215
alt
5000-10401
alt
76-0235-0252
alt
76-120-14582-00-A
alt
76-120-15050-00
alt
76-150-14390-04
alt
76-150-14391-10
Image
SKU
Description
alt
3014B1212
alt
3014B1213
alt
3014B1214
alt
3014B1215
alt
5000-10401
alt
76-0235-0252
alt
76-120-14582-00-A
alt
76-120-15050-00
alt
76-150-14390-04
alt
76-150-14391-10