https://sps.honeywell.com/us/en/search-results.html

Portables

MultiRAE Lite Pumped

Wireless, portable multi-gas monitor

his-rae-multirae-lite-pump-front-hires
This multi-gas monitor provides versatile, customizable detection and monitoring of up to six gases, available in both pumped and diffused air models. With more than 25 sensors to choose from — the broadest selection in its class — it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a range of industries and applications. The wireless connection sends threat and alarm data in real time to a central command, providing superior awareness for fast incident response. And its replaceable sensors, alarm, and battery, large screen, and automated bump testing and calibration make it easy to use and maintain. Features and Benefits: • Multi-gas monitor for 1-6 gases • Pumped and diffusion models available • Man down alarm • More than 25 different chemical sensors • Fully automatic bump testing and calibration • Real-time access to readings at central command • Swap out sensors as needed • Simple maintenance with replaceable sensors, pump, and battery • 5-way local and remote wireless alarm • Multi-language capability – up to 18 languages • Device Management with Honeywell Sotera™ Express Application: • Clandestine Labs • Confined Space Entry • Emergency Response • Environmental Cleanups/ Remediation • Exploration • Fire Overhaul • Fracking • Hazmat Response • Plant Shutdown & Turn-Around • Urban Search & Rescue

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Humidity Range
    • 0%-95%
  • Benefits
    • Highly versatile and customizable
  • Sub-Category
    • Multi-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 122 degree Fahrenheit
  • Weight
    • 880 gram
    • 31 ounce av [Invisible]
  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • BLE
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time
    • 12-18
  • Warranty
    • Four years on Liq O2 sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Others

  • Alarm Type
    • Audible, Visual, Vibrating
  • Sensor Range
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Humidity Range
    • 0%-95%
  • Benefits
    • Highly versatile and customizable
  • Sub-Category
    • Multi-Gas
  • Maximum Temperature
    • 50 degree Celsius
    • 122 degree Fahrenheit
  • Weight
    • 880 gram
    • 31 ounce av [Invisible]
  • Standards
    • CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Sampling Pump Range
    • 100ft (30m)
  • Brand
    • RAE
  • Wireless Technology
    • BLE
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging
    • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time
    • 12-18
  • Warranty
    • Four years on Liq O2 sensors
  • Ingress Protection
    • IP65
  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Alarm Type : Audible, Visual, Vibrating
  • Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Humidity Range : 0%-95%
  • Benefits : Highly versatile and customizable
  • Sub-Category : Multi-Gas
  • Maximum Temperature : 50 degree Celsius|122 degree Fahrenheit
  • Weight : 880 gram|31 ounce av [Invisible]
  • Standards : CSA: Class I, Division 1, Groups A, B, C, and D, T4
  • Sampling Pump Range : 100ft (30m)
  • Brand : RAE
  • Wireless Technology : BLE
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
  • Battery Run Time : 12-18
  • Warranty : Four years on Liq O2 sensors
  • Ingress Protection : IP65
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
Data Sheet
Name
Description
File Size
Date
Size
MultiRAE Lite Diffused &�Pumped Data Sheet
137.81 KB
12/4/2020
PDF 137.81 KB
Manuals and Guides
Name
Description
File Size
Date
Size
MultiRAE (Pumped) QuickStart Guide
302.5 KB
12/4/2020
PDF 302.5 KB
MultiRAE User Guide
8.12 MB
12/4/2020
PDF 8.12 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/4/2020
PDF 839.32 KB
MultiRAE Series Technical Note 106B
620.4 KB
12/4/2020
PDF 620.4 KB
A Guideline for Pid Instrument Response
1.45 MB
12/4/2020
PDF 1.45 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
12/4/2020
PDF 125.12 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
12/4/2020
PDF 839.29 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
12/4/2020
PDF 994.45 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
12/4/2020
PDF 609.21 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
12/4/2020
PDF 750.26 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
12/4/2020
PDF 984.3 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
12/4/2020
PDF 785.04 KB
Technical Note 124 PID Lamp Characteristics
768.24 KB
12/4/2020
PDF 768.24 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
12/4/2020
PDF 820.7 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
12/4/2020
PDF 911.54 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
12/4/2020
PDF 795.02 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 000: RAE Systems PID Overview
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
12/4/2020
PDF 1 MB
Application 202: The ABC�۪s Of Gases In The Industry
843.47 KB
12/4/2020
PDF 843.47 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
12/4/2020
PDF 901.23 KB
Name
Description
File Size
Date
Size
Technical Note 148 Defining The Interval Between Calibration Checks
839.32 KB
12/4/2020
PDF 839.32 KB
MultiRAE Series Technical Note 106B
620.4 KB
12/4/2020
PDF 620.4 KB
A Guideline for Pid Instrument Response
1.45 MB
12/4/2020
PDF 1.45 MB
MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
125.12 KB
12/4/2020
PDF 125.12 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
12/4/2020
PDF 839.29 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
994.45 KB
12/4/2020
PDF 994.45 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
12/4/2020
PDF 609.21 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
750.26 KB
12/4/2020
PDF 750.26 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 141 Monitor Remote Control Functions
984.3 KB
12/4/2020
PDF 984.3 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
12/4/2020
PDF 785.04 KB
Technical Note 124 PID Lamp Characteristics
768.24 KB
12/4/2020
PDF 768.24 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
820.7 KB
12/4/2020
PDF 820.7 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
911.54 KB
12/4/2020
PDF 911.54 KB
MultiRAE (Pumped) QuickStart Guide
302.5 KB
12/4/2020
PDF 302.5 KB
MultiRAE User Guide
8.12 MB
12/4/2020
PDF 8.12 MB
Application Note 000: RAE Systems PID Overview
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
655.59 KB
12/4/2020
PDF 655.59 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
12/4/2020
PDF 1 MB
Application 202: The ABC�۪s Of Gases In The Industry
843.47 KB
12/4/2020
PDF 843.47 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
901.23 KB
12/4/2020
PDF 901.23 KB
MultiRAE Lite Diffused &�Pumped Data Sheet
137.81 KB
12/4/2020
PDF 137.81 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
795.02 KB
12/4/2020
PDF 795.02 KB
Technical Note 120_Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
624.75 KB
12/4/2020
PDF 624.75 KB
Technical Note 130 Setting Alarm Limits For Mixtures
788.83 KB
12/4/2020
PDF 788.83 KB
Image
SKU
Description
alt
MAA3-0EC1123-320
MultiRAE Lite-Pumped / O₂ / LEL / H₂S / CO / SO₂ / Li-ion / Wireless (868 MHz)/Unit only
alt
MAA3-0EC1RN0-020
MR LT/ATX/PMP/O2/LEL/CO+H2S/H2S/ N-WS
alt
MAA3-0EC1R00-320
MR LT/ATX/PMP/O2/LEL/CO+H2S/ 868M
alt
MAA3-B8C102E-020
MultiRAE Lite-Pumped / CO₂ / LEL / CO / O₂ / Li-ion / Non-Wireless/Unit only
alt
MAA3-0405300-021
MR LT/ATX/PMP/NO/NO2/SO2/ N-WS
alt
MAH3-A2C108E-011
MR LT/CU/PMP/PID/LEL/ NH3/O2/N-WS
alt
MAA3-0108H00-020
MR LT/ATX/PMP/H2S/NH3/CH4S/ N-WS
alt
MAA3-07C1R89-020
MR LT/ATX/PMP/HCN/LEL/CO+H2S/NH3/PH3/N-W
alt
MAH3-A200000-011
MR LT/CU/PMP/PID/ N-WS
alt
MAA3-A2C113E-020
MR LT/ATX/PMP/PID/LEL/H2S/SO2/O2/N-WS