Portables
MultiRAE Benzene
Wireless Portable Multi-Gas Monitor With Benzene-Specific Measurement
The MultiRAE Benzene monitor combines the ability to make quick benzene-specific assessment (“snapshot”) measurements with the advantages of a versatile multi-gas monitor that can support approximately 20 intelligent interchangeable sensor options. Its optional wireless capability improves safety by providing real-time access to instrument readings and alarm status from any location, which delivers better situational awareness and faster incident response in a wide range of different applications.
Features and Benefits:
• Optional integrated wireless
• Snapshot Benzene specific measurement capability
• 20 field-interchangeable sensor options, including PID, LEL, and exotics like ammonia, chlorine, and formaldehyde
• Five local and remote alarms, including man down
• Dust-tight and waterproof (IP65-rated)
• Rugged design
• Long battery run-time
• Intuitive, icon-driven interface
• Flippable screen
• Large buttons for easy navigation even with up to three glove layers
• Continuous data logging — six months for five sensors 24/7
• Fully automated bump testing and calibration with AutoRAE 2
• Device Management with Honeywell Sotera™ Express
Application:
• Confined Space Entry
• Exploration
• Fracking
• Leak Detection
• Plant Shutdown & Turn-Around
Others
- Alarm Type
- Audible, Visual, Vibrating
- Sensor Range
- NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), Benzene (0-200ppm)
- Minimum Temperature
- -20 degree Fahrenheit
- Humidity Range
- 0%-95%
- Benefits
- Highly versatile and customizable
- Sub-Category
- Premium-Gas
- Maximum Temperature
- 50 degree Fahrenheit
- Standards
- CSA: Class I, Division 1, Groups A, B, C, and D, T4
- Weight
- 880 ounce av [Invisible]
- Sampling Pump Range
- 100ft (30m)
- Brand
- RAE
- Wireless Technology
- MESH, Wifi, BLE
- Gas Type
- NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2, Benzene
- Datalogging
- Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
- Battery Run Time
- 12-18
- Warranty
- Four years on Liq O2 sensors
- Ingress Protection
- IP65
- User Options
- 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
- Instrument Size
- 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
Others
- Alarm Type
- Audible, Visual, Vibrating
- Sensor Range
- NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), Benzene (0-200ppm)
- Minimum Temperature
- -20 degree Fahrenheit
- Humidity Range
- 0%-95%
- Benefits
- Highly versatile and customizable
- Sub-Category
- Premium-Gas
- Maximum Temperature
- 50 degree Fahrenheit
- Standards
- CSA: Class I, Division 1, Groups A, B, C, and D, T4
- Weight
- 880 ounce av [Invisible]
- Sampling Pump Range
- 100ft (30m)
- Brand
- RAE
- Wireless Technology
- MESH, Wifi, BLE
- Gas Type
- NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2, Benzene
- Datalogging
- Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
- Battery Run Time
- 12-18
- Warranty
- Four years on Liq O2 sensors
- Ingress Protection
- IP65
- User Options
- 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
- Instrument Size
- 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
- Alarm Type : Audible, Visual, Vibrating
- Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), Benzene (0-200ppm)
- Minimum Temperature : -20 degree Fahrenheit
- Humidity Range : 0%-95%
- Benefits : Highly versatile and customizable
- Sub-Category : Premium-Gas
- Maximum Temperature : 50 degree Fahrenheit
- Standards : CSA: Class I, Division 1, Groups A, B, C, and D, T4
- Weight : 880 ounce av [Invisible]
- Sampling Pump Range : 100ft (30m)
- Brand : RAE
- Wireless Technology : MESH, Wifi, BLE
- Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2, Benzene
- Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
- Battery Run Time : 12-18
- Warranty : Four years on Liq O2 sensors
- Ingress Protection : IP65
- User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
- Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
Technical Note
Name
Description
File Size
Date
Size
Technical-Note 148_Defining-The-Interval-Between-Calibration-Checks_12-15.pdf
839.32 KB
12/4/2020
PDF 839.32 KB
Technical-Note-106_A-Guideline-for-Pid-Instrument-Response.pdf
1.45 MB
12/4/2020
PDF 1.45 MB
Technical Note 144_Handling LEL Sensor Poisons
802.28 KB
12/4/2020
PDF 802.28 KB
Technical Note 152_Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
12/4/2020
PDF 839.29 KB
Technical Note 156_Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
12/4/2020
PDF 609.21 KB
Technical Note 121_CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
12/4/2020
PDF 785.04 KB
Technical Note 146_Turning On UV Lamps In A PID Monitor
787.55 KB
12/4/2020
PDF 787.55 KB
Technical Note 124 PID Lamp Characteristics
768.24 KB
12/4/2020
PDF 768.24 KB
Technical Note 151 Electrochemical Sensor Replacement & Maintenance
976.3 KB
12/4/2020
PDF 976.3 KB
MultiRAE Benzene / RAE-Sep Tube Cartridge One Sheet
191.58 KB
12/4/2020
PDF 191.58 KB
Technical-Note-114_updated_03-26-2018.pdf
795.02 KB
12/4/2020
PDF 795.02 KB
Application Note
Name
Description
File Size
Date
Size
TN-204 Modes & Applications For The MultiRAE Benzene
226.06 KB
12/4/2020
PDF 226.06 KB
Application Note 000_RAE Systems PID Training Outline
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
12/4/2020
PDF 1 MB
Application Note 236 Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
729.36 KB
12/4/2020
PDF 729.36 KB
Application Note 233 Wireless Mesh Gas Detection For Oil And Gas Exploration
727.86 KB
12/4/2020
PDF 727.86 KB
Application Note 217 Confined Spaces And The Construction Industry
828.21 KB
12/4/2020
PDF 828.21 KB
Application Note 231 AreaRAE Inert for Inert Gas Confined Space Entry
964.06 KB
12/4/2020
PDF 964.06 KB
Application Note 202 The ABC’s Of Gases In The Industry
843.47 KB
12/4/2020
PDF 843.47 KB
Application Note 215_Gas Detection In The Marine Industries
889.61 KB
12/4/2020
PDF 889.61 KB
Application Note 221_Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
12/4/2020
PDF 964.88 KB
Application Note 219 Using PIDs For 10% Of LEL Decisions
1.1 MB
12/4/2020
PDF 1.1 MB
Manuals and Guides
Name
Description
File Size
Date
Size
MultiRAE (Pumped) QuickStart Guide
302.5 KB
12/4/2020
PDF 302.5 KB
Data Sheet
Name
Description
File Size
Date
Size
Datasheet_MultiRAE Benzene_DS-1098-11_US-EN_HR.pdf
118.19 KB
12/4/2020
PDF 118.19 KB
Others
Name
Description
File Size
Date
Size
Product Notice 2017053B _SAFETY ADVISORY
125.12 KB
12/4/2020
PDF 125.12 KB
Name
Description
File Size
Date
Size
Technical-Note 148_Defining-The-Interval-Between-Calibration-Checks_12-15.pdf
839.32 KB
12/4/2020
PDF 839.32 KB
TN-204 Modes & Applications For The MultiRAE Benzene
226.06 KB
12/4/2020
PDF 226.06 KB
Technical-Note-106_A-Guideline-for-Pid-Instrument-Response.pdf
1.45 MB
12/4/2020
PDF 1.45 MB
Product Notice 2017053B _SAFETY ADVISORY
125.12 KB
12/4/2020
PDF 125.12 KB
Technical Note 144_Handling LEL Sensor Poisons
802.28 KB
12/4/2020
PDF 802.28 KB
Technical Note 152_Effects Of Operating Conditions On Oxygen Sensors
839.29 KB
12/4/2020
PDF 839.29 KB
Technical Note 156_Correction Factors For Combustible Gas LEL Sensors 20022016
609.21 KB
12/4/2020
PDF 609.21 KB
Technical Note 121_CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
785.04 KB
12/4/2020
PDF 785.04 KB
Technical Note 146_Turning On UV Lamps In A PID Monitor
787.55 KB
12/4/2020
PDF 787.55 KB
Technical Note 124 PID Lamp Characteristics
768.24 KB
12/4/2020
PDF 768.24 KB
Technical Note 151 Electrochemical Sensor Replacement & Maintenance
976.3 KB
12/4/2020
PDF 976.3 KB
MultiRAE (Pumped) QuickStart Guide
302.5 KB
12/4/2020
PDF 302.5 KB
MultiRAE Benzene / RAE-Sep Tube Cartridge One Sheet
191.58 KB
12/4/2020
PDF 191.58 KB
Application Note 000_RAE Systems PID Training Outline
1.1 MB
12/4/2020
PDF 1.1 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
1 MB
12/4/2020
PDF 1 MB
Application Note 236 Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
729.36 KB
12/4/2020
PDF 729.36 KB
Application Note 233 Wireless Mesh Gas Detection For Oil And Gas Exploration
727.86 KB
12/4/2020
PDF 727.86 KB
Application Note 217 Confined Spaces And The Construction Industry
828.21 KB
12/4/2020
PDF 828.21 KB
Application Note 231 AreaRAE Inert for Inert Gas Confined Space Entry
964.06 KB
12/4/2020
PDF 964.06 KB
Application Note 202 The ABC’s Of Gases In The Industry
843.47 KB
12/4/2020
PDF 843.47 KB
Application Note 215_Gas Detection In The Marine Industries
889.61 KB
12/4/2020
PDF 889.61 KB
Application Note 221_Using PIDs To Assess Exposure Risk In Unknown Environments
964.88 KB
12/4/2020
PDF 964.88 KB
Application Note 219 Using PIDs For 10% Of LEL Decisions
1.1 MB
12/4/2020
PDF 1.1 MB
Datasheet_MultiRAE Benzene_DS-1098-11_US-EN_HR.pdf
118.19 KB
12/4/2020
PDF 118.19 KB
Technical-Note-114_updated_03-26-2018.pdf
795.02 KB
12/4/2020
PDF 795.02 KB